Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehdiunitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facirity Morada Chevron Facility 10878 N Hwy 99, Stockton <br />�',n,�`ZPec�'10"Ja�n27 <br />, 2012 <br />Name: Address: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M Code Section <br />HSC = CA Health and Safe Code; CFR = Code of Federal R ulations <br />C1 = Class violation; C2 = Class 2 violation; M = Minor violation <br />-1 <br />On Site Records (continued) <br />Designated operator monthly inspection: (1) alarms not documented; (2-4) spill containers, UDCs, and sumps <br />204 CCR 2715(c) if necessa not inspected; 5 required test dates not checked or noted; B employee training not verified <br />205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br />Designated operator employee training: (1) not performed; (2) not current for at least one employee on site; <br />206 CCR 2715(0 3 log not kept <br />207 HSC 25281.5(b)(2) I Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />Observations <br />301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 X HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary c°ntainment(Ml ) <br />303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br />304 X CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (M1) <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates an (M1) <br />305 CCR 2636(f)(1) audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 CCR 2631(a) Primary containment is not product tight <br />307 HSC 25291(a)(2) Secondary containment for UST system is not tight <br />308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />309 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br />310 HSG 25291(e) Water in 2° containment not removed, analyzed & properly disposed of <br />311 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (M1) <br />312 CCR 2635(b) No spill container or overfill prevention system installed (M2) <br />Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (M2) <br />313 CCR 2635(b)(1) the spill container empty <br />314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (M2) <br />315 HSC 25299(1)(2) Tampering with or disabling leak detection devices or alarms <br />316 CCR 2631.1(a) UST system is not compatible with the substance stored <br />317 HSC 25298(a) Illegally abandoned UST system <br />AB 1702 (2003-2004) HSC 25290.1 (installed between 07101103 and 06130104) <br />VPH Systems HSC 25290.1 jinstalled on or after 07/01104 <br />Compatibility and permeability requirements: (a) UST system is not oompabble with the substance stored; (b) <br />401 <br />CCR 2631.1 <br />results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b) and (d) <br />for a UST s stem installed after July1, 2004, were not submitted <br />402 <br />HSC 25290.1(c)(1) <br />Primary containment not liquid or vapor tight <br />HSC 25290.2(c)(1) <br />403 <br />HSC 25290.1(c)(2) <br />Secondary containment not liquid or vapor tight <br />HSC 25290.2(c)(2) <br />404 <br />HSC 25290.1(c)(3) <br />Secondary containment not constructed to prevent water intrusion <br />HSG 25290.2(c)(3) <br />HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />405 HSC 25290.2 d liquid or vapor from the rima containment into the seconda containment <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />406 HSC 25290.1 (e) UST system not maintained <br />HSC 25290.16) UST system not tested by one of the following methods prior to use:. (1) Enhanced leak detection; (2) inert gas <br />407 HSC 25290.2 i ressure testa roved b SWRCB; 3 test method deemed equivalent to 1 or 2 b the SWRCB <br />Emergency Generator Systems <br />5011 CCR 2636(f (6) Emergency generator monitoring system not checked daily or log not kept if no leak detector (M1) <br />502 1 1 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br />USTs In a Vault <br />601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br />603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 HSC 25283.5(a)(5) UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />Non -Pressurized Piping <br />701 CCR 2643(d) Daily monitoring of on piping (pre -January 1, 1984) not performed (M1) <br />Inspector. R y: Trtle: <br />Garrett Backus (209} 468-2986 <br />EHE 23-02 Rev 09101/11 Page 2 U5 SPECTION REPORT <br />