Laserfiche WebLink
Page 3of5 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www,sQov.oralehd <br />Underground Storage Tank Program inspection Report <br />Facility <br />Name: <br />Facility Address: Date: <br />1 <br />MORADA CHEVRON FAST N EASY 460" 10878 N HWY 99 STOCKTON Aril 22 2015 <br />UST System Observations <br />319 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2043) <br />o V o R ❑ COS <br />320 <br />HSC 25290.1(c3), <br />Secondary containment not constructed to prevent water intrusion <br />n V ❑ R c COS <br />25290.1(c3) <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />o V ❑ R ❑ COS <br />322 <br />CCR 26360(2) <br />Line leak detector not installed <br />❑ V ❑ R n COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />■ V r R u COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />u V o R ❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />o V ❑ R c COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />n V Ei R ❑ COS <br />327 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />u V n R ❑ COS <br />328 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />329 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />n V ❑ R ❑ COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />n V ❑ R ❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />n V ❑ R ❑ COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />o V ❑ R ❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />a V o R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />a V ❑ R u COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V ❑ R u COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V o R u COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />-i V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />o V ❑ R u COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R a COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS ll, or MANOR - Notice to Comply} <br />Item # <br />Remarks <br />109 <br />CCR 2637 Failed <br />to test secondary containment. <br />Secondary containment testing was last performed on October 24, 2011 and was due by August 2014. <br />Testing has <br />not been completed and is 8 months past due. Secondary containment testing is required once every 36 months. <br />Immediately schedule this test and provide 48 hours notification to the E'HD. <br />This is a Class II violation. <br />Received byInspector: <br />�, `� <br />Phone: <br />Date: <br />(initial): <br />FATINAH ZAREEF, REHS <br />(209) 953-7311 <br />04/22/2015 <br />Page 3of5 <br />