My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1993 REMOVAL PLAN
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
25651
>
2300 - Underground Storage Tank Program
>
PR0231628
>
REMOVAL_1993 REMOVAL PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:31 PM
Creation date
11/5/2018 7:59:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1993 REMOVAL PLAN
RECORD_ID
PR0231628
PE
2361
FACILITY_ID
FA0003835
FACILITY_NAME
SMK CHEVRON
STREET_NUMBER
25651
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00514120
CURRENT_STATUS
01
SITE_LOCATION
25651 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\25651\PR0231628\REMOVAL PLAN 1993.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 1 4 15 6 7 8 9 10 11 1 12 13 14 ' 15 16 17 1g <br /> 6" CONC. SLAB \ <br /> ASPHALT PAVING 48" <br /> ' BASE MATERIAL 24 I 1-1/2" INLET-(3) DISPENSER <br /> M22-1 2" 45 / 3/4" CONDUIT FOR SUMP PROBE - 1 1/2"0 PIPE RISER JUNCTION BOX <br /> 3/4" PVC PUMP OUT PIPE <br /> 21• (EXPLOSION PROOF) <br /> WITH THREADED FITTING UNION (FURNISHED BY <br /> 10-1 2" 10-1 2" 3" 15/16" DIA. HOLES-(4) FUEL DISPENSER. - - DISPENSER MANOR.) SEAL OFF <br /> III-I 5 1/4 THIS VAPOR LINE OMITTED ON SHEAR VALVE <br /> � '� (SHEAR SECTION FLUSH <br /> ? - I ���_ I �Is SINGLE SIDED DISPENSERS WITH THE TOP OF PIPE CAP WITH HOLE FOR <br /> IIIL.. o PUMP BLOCK) CONTROL WIRES <br /> L <br /> SEAL "WATER TIGHT' AT <br /> PER 12 <br /> OPE CONCRETE 1 1/2' ALL OPENINGS <br /> . . ., <br /> f <br /> " TVP. <br /> _ _-_-____- STABILIZER BAR <br /> L L <br /> OUTLET 1-1/2" N,P.T, 3" 3/4" x 1-I/2" SLOT, (3) n <br /> ' ' - " (WITH OPTIONAL 47271- 1D" 3/4" CONDUIT --- ---��f`,Z. _ FRP CONTAINMENT SYSTEM <br /> PEA GRAVEL VAPOR RECOVERY MANIFOLD ONLY) _ REDUCE VAPOR TO DISPENSER DRIP BOX 3/4" CONDUIT TO CONTROL <br /> _III_II_I�' 2"0 LINE IN 3"�>Ec, PANEL (POWER) <br /> CCN !'IpoCNI') 45' STEEL ELBOW <br /> 40 MULTI-GRADE DISPENSER BASE 2" m ''.R 3/4" CONDUIT TO CONTROL <br /> GP'PESEG, CcN• _ _ _ _ PANEL (DATA) <br /> NOTE: CONTRACTOR TO VERIFY DISPENSER SCALE: 0' C UMP <br /> CONDUIT, AIR AND WATER / - <br /> 6 1/2'• MIN. LINES TO CROSS DIMENSIONS IN FIELD 3/4" CONDUIT FOR SUMP <br /> PERPENDICULAR TO PIPE. O PENETRATION PROBE TO CEI 3000 <br /> RUN PRODUCT PIPING <br /> AND ELECTRICAL P' PVC PIPE OPEN AT K <br /> K - CDNDIJn INTO fi 1/2' BOTTOM. ATTACH TO SUMP <br /> 3 PIPE TRENCH SCALP. NONE _ _ MIN. J" FRP AS NEEDED FOR SUPPORT. <br /> 2' 0 PRODUCT IN DPPENSE SIDES OF CONTAINMENT PIPE <br /> \ - 3' 0 SEC. CON. PIPE DISPENSERS - P OVIDE MINIMUM NA <br /> (SEE PIPING FLAN) C, �� 2R1/T CLEARANCE API/RO N LS-3 PROBE <br /> BETWEEN PIPE AND 2 FRP PIPE <br /> FITTINGS <br /> 2" V.R S' TO 7•' REDUCER I 1/2"M SWIVEL x 2"F <br /> °Q x.EA ' BOOT <br /> 24" FLEX CONNECTOR <br /> VENT RISERS, <br /> 3"x <br /> SEE SITE PLAN FOR ACTUAL LOCATION. �\ Tx2" PRODUCT <br /> INSTALL MAXIMUM SLOPE FROM TANK _F,R.P. TEE [)U CT 2" BELL & MALE F.R.P. <br /> UP TO VENT RISER. (MIN. SLOPE 1/4"/FT.). ' THREADED ADAPTOR <br /> 3" 0 V.P.V. .I �\\ ` � �� <br /> 4°�>EC. GcN •FIFE <br /> J 3' VAPOR LINE TEE - J <br /> IN G"IP SE6 CKT4• PIPE <br /> 2'0 PRODUCT <br /> N 3"0 SEC CON GENERAL CONTRACTOR TO <br /> 3" 0 V.R. TEE PROVIDE RIGID PIPING IF EACH <br /> ,, PIPE VAPOR RECOVERY MANIFOLD DISPENSER <br /> jSLOPE VAPOR RETURN LINE `� F-1 <br /> 1/4" PER FT. MIN. DOWN TO -..,`` SLOPE PRODUCT LINES <br /> ( ` REGULAR TANK. F 1/4" PER FOOT MINIMUM - 1 I/2" x 1' <br /> FROM DISPENSERS TO TANK (TTP.) REDUCING BUSHING <br /> SEE NOTE 8. <br /> — n H w \`\ - SHEAR RING <br /> uu - <br /> NOTE: <br /> H -- 4 ' \�`�� -:/" FIBERGLASS SUMP <br /> - H <br /> 2° 0 F.1 4 VENT LINES. 3 - ' <br /> SLOPE I/9" PER FOOT MIN. F-2 \`� FOR CLARITY, _. , <br /> 3/4" P.V.C. PUMP OUT <br /> GOWN TO TANKS. ' F-2 45' STEEL ELBOW PIPE WITH THREADED FITTING <br /> TA16)ME NT SUMP <br /> ON <br /> (1Y <br /> i S 2 _ <br /> E F_� -- 3"0 FRP <br /> 6" _ �'Z� '� ` \ c j] "� VAPPR RETURN I I/"2.M SWIVEL x 2"F <br /> \ l IN 4 :=c cPN• P', Ts 24" FLEX CONNECTOR <br /> VENT RISER �� <br /> (TVP.) �\ <br /> SUMP PENETRATION <br /> 8" �`���\��_ 2 V.R. - - BOOT <br /> --/ IN e¢G I -- 2" BELL & MALE F.R.P. <br /> Q 2"0 BLACK IRON THREADED CONCRETE <br /> 8" IN 4'r� EEG.V.R.--/ <br /> • T`, _ �.,fu N �, \ _ V 3' TO 2" REDUCER BLOT THREADED ADAPTOR <br /> FEMALE COUPLING, PRIMED COLLAR O PdFE � - �� � � � � � � •• N T� 3 � \ � � VAPOR RECOVERY Q <br /> 2" BLACK BELOW IRON PIPERADE PRIMED 4"X.4-X3' F.R,P. TEE CaN V,R. <br /> hEG. <br /> & WRAPPED BELOW GRADE F- 1 EA } ° .R c_ NO SCALE / <br /> SUP <br /> CONCRETE ` 7 UN�R UED IN 4• a ` �, �� ' \ ' \ �5 DISPENSER PIPING <br /> 2"x24" FLEX CONNECTOR COLLAR - hCG' tJ -� 3" 0 <br /> WITHIN CONTAINMENT BOOT P'-US � <br /> -TERMINATE BELOW GRADE- \_ UN`FAI)F_U o V � \� IDI ES• <br /> 1 . PIPING PLAN SHOW'S TYPICAL PIPING FOR MULTI-PRODUCT DISPENSERS, <br /> F 1 x4'xs7FR.P. TEE ReCUFAR I� SEE PLANS FOR SPECIFIC TYPE OF DISPENSERS TO BE USED AT THIS LOCATION. P <br /> F-1 �N�EAflFp 2. ALL PRODUCT pNn VAFcVr' EEr_cbEfx,Y uN6, A r, PE. ;gu:N�Fyx14Y ecrNTAIN2e� <br /> 2" FRP VENT PIPE <br /> 3. EVERY TANK SUMP AND DISPENSER DRIP BOX WILL CONTAIN A LIQUID PROBE. <br /> To TANK SEE SITE PLAN FOR - 4 CAULK BOTTOM OF DISPENSERS TO INSURE WATER TIGHTNESS. <br /> EXACT A LocgiloN <br /> OF STORAGE RACE TANKS <br /> 5. PERPENDICULAR PENETRATIONS OF CONTAINMENT SUMPS PREFERRED, <br /> 20' IS MAXIMUM ALLOWABLE PENETRATION ANGLE. <br /> 1 UNDERGROUND TANK AND PIPING ISOMETRIC N T S 6. SPARE ELECTRICAL CONDUITS MUST BE SEALED. <br /> 7. SEE ELECTRICAL SHEET E- 1 FOR CONDUIT LAYOUT. <br /> E - 8. OBTAIN WRITTEN APPROVAL FROM CHEVRON FOR LESS E <br /> BASE DETAIL N.T.S <br /> THAN 1/4" PER FOOT PRODUCT, VAPOR AND VENT PIPE SLOPE. <br /> -\ 9. ALL STEEL PIPINGBE SCH. 40 BLACK IRON. <br /> PRIME AND WRAPAP ALL STEEL PIPING AND RISERS. <br /> BOLTS HOLD FITTING <br /> NOTE'. 3' :ErGNDARv PTL - TOGETHER WHILE <br /> OVERALL DIMENSION 1.THE CONNECTION FOR REGULAR UNLEADED DOES 11 T PECNIPE 711,- 5 RISE. A RESIN CURES. - <br /> DETERMINED BY NUMBERrrG .YHEKE ocGURS� <br /> OF RISERS AND/OR ANY POTEN7IAL LIQUID IN THE VAPOR PIPE SHALL FALL INTO THE - <br /> LOCAL CODE. REGULAR UNLEADED TANK. , <br /> 2.AI.t"VA.•`cUP,f2GTUkN LINE's6 <br /> 5 AIUP 0NH6C-F0NO To (3E Gi�GoNDaR14Y GO N'YAINP.p <br /> D PRESSURE VACUUM VALVE 2" FRP — �2" FRP <br /> AS REQUIRED BY LOCAL CODE ,a 45' ELBOW . \ <br /> �' --- APPLY RESIN TO FLANGE' <br /> 1/4" BEVEL BUTT o 2" PRIMARY PIPE TOS, <br /> WELD-SMOOTH. -- BE LING S PRIOR TO <br /> SEALING SECONDARY <br /> 2" FRP REDUCER TEEE <br /> }" X 2' FRP , PIPE MARK DATREVISIONS INFTTAL <br /> D <br /> 4" 111 TUBE FRAME 49.' \ '\ <br /> PAINT DARK GREY TANK AND PIPING ISOMETRIC <br /> CY-210 —3" FRP <br /> FASTEN VENT AND DETAILS <br /> 2" 0 SCH, 40 BLACK RISERS SECURELY <br /> IRON PIPES TO FRAME WITH �,NL4JN <br /> c (PRIMED AND q PRE-FARMED PHASE R VAPOR LINE CONNECTIONS <br /> RADE)WRAPPED BELOW I ry UNISTRLIT BRACKETS. �� \ 9 2396 c <br /> DARK GREY 10- ( PLUS UNLEADED AND SUPREME UNLEADED) / 25650 AMPHWY , <br /> PAINT . <br /> GY-210 TYP. NOTE: �\�\M�M \ / / ACMPOCAA. <br /> PTE COUPLING (TYP.) }„ ALL CROSS OVER PIPING TO BE - <br /> �II TANK PWG - TORQUE TO MADE WITH TEE (OR 90' ELL), <br /> M CONC. COLLAR ' 1 300 FT.-LBS. PRIOR TO SHORT NIPPLE AND 45' ELL. / Chevron <br /> FLUSH W/YARD INSTALLING ISOLATION CAP ISOLATION CAP •• / <br /> SURFACE g V 0M• < / <br /> TANK FITTING <br /> E, E� <br /> GE SCS 1202 COMPRESSION RING / - Northwest Region <br /> B apt' 0 CONCRETE { � .I SILICONE SEALEANT - <br /> B <br /> .FOOTING, SLOPE �..I� f;1 - / ISOLATION - <br /> 3" F.R.P. 45' ELL <br /> AT TOP (TYP.)TYP' TANK FITTING BASE 3" SLOPE PIPING TOWARD ROBERT H. LEE & ASSOCIATES, INC. <br /> F.R.P. NIPPLE <br /> BASE � UNDERGROUND FUEL ggCHtTECTVRE ENdNEERNJQ ENVIRONMEMAL BERVK:EB <br /> 3' F.R.P. TEE STORAGE TANKS AT 1137 NORTH MODO'NELL BOULEVARD PETALUMA CA. 94954 (707) 765-1660 <br /> " <br /> 1/4PER FOOT MINIMUM, <br /> I b - JOHN W. JOHNSON. ARCHITECT JAMES H. RAY, CIVIL ENGINEER <br /> 3 F.R.P. PIPE (TYP.) RHL REVIEW INFTIAL DATE DATE: <br /> N ABOVE SEE DETAIL UNUSED FITTING B�za �r3 <br /> PRELIMINARY <br /> 0- 0 VENT RISER SCALE: 1/4" 08 TANK FITTING ISOLATION DETAIL O PIPING CROSSOVER NO SCALE PLANNING DR. BY: <br /> STEEL BID <br /> /7 BLDG PERMIT Z APPR.: SPG A <br /> O A �/ \\\ / GENERAL BID RHL M 8344.10 <br /> Z <br /> PERMIT REV'S <br /> LO CONSTRUCTION SHEET <br /> Z Do not use drawing <br /> - for construction F-1 <br /> 4 <br /> K <br /> unless initialed <br /> • 1 2 3 4 5 6 7 8 9 10 11 12 13� 14 15 16 17 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.