My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:17:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2010-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 . 0 Page 6. <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer Industry Standard Xl Professional Engineer <br /> ❑ Other (Specify) <br /> Test Method Used: ❑ Pressure Vacuum Hydrostatic <br /> ❑ Other (Spec) <br /> Test Equipment Used: vp1t Equipment Resolution: +-002" <br /> UDC# 9/10 UDC# 11/12 UDC# UDC# <br /> UDC Manufacturer: environ environ <br /> UDC Material: hpde hpde <br /> UDC Depth: 36" 36" <br /> Height from UDC Top to Top of 91, 91, <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 3" 3" <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Tested: t ill, 11" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Elyes ENoE]N E]Yes[�]NoE]N Yes E]ND❑N E]Yes l:]No[:]N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec <br /> Is system programmed for fail-safe ❑ ❑ � ❑ ❑ � ❑ ❑ <br /> shutdown?* Yes N N X❑yes N N Yes N N Yes No <br /> Was fail-safe verified to be ❑ ❑ � ❑ ❑ � ❑ ❑ [r <br /> operational?* X Yes N N X❑yes❑N�N X Yes N N Yes No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min <br /> test: <br /> Test Start Time: 11:55 12: 16 <br /> Initial Reading(Rt): 0 0 <br /> Test End Time: 12:10 12:31 <br /> Final Reading(RF): -.0000" +.0004" <br /> Test Duration: 15min 15min <br /> Change inReading(RF-Rt ): -.0000" +.0004" <br /> Pass/Fail Threshold or Criteria: +-002" +-002" <br /> Test Result: M Pass D FailLLJ Pass Fail Pass 0 Fail 0 Pass E Fail <br /> Was sensor removed for testing? IflYesE]NoENA X Yes NoE]NA EYesEN NA Yes No <br /> Was sensor properly replaced and MYes❑NC]NA E]Yes❑Nc❑NA ❑Yes❑NcENA Yes�No❑N <br /> verified functional after testing? <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> t If the entire depth of the UDC is not tested,specify how much was tested.If the answer to my of the questions indicated with an <br /> asterisk(*)is"NO" or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.