My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:17:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2010-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 . 0 Page 5. <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer Industry Standard X� Professional Engineer <br /> ❑ Other (Spec) <br /> Test Method Used: ❑ Pressure 0 Vacuum X❑ Hydrostatic <br /> ❑ Other (Spec) <br /> Test Equipment Used: volt Equipment Resolution: +-002" <br /> UDC# 1/2 UDC# 3/4 UDC# 5/6 UDC 7/8 <br /> UDC Manufacturer: environ environ environ environ <br /> UDC Material: hpde hpde hpde hpde <br /> UDC Depth: 36" 36" 36" 36" <br /> Height from UDC Top to Top of 91, 91, y„ 91, <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 3" 3" 3" 3" <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good good good <br /> Portion of UDC Tested: t 11" 11" 11" 11" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ayes[:]No❑N ayes[:]No❑N aYes allo❑N X❑Yes E]No[:]N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec 2-5sec 2-5sec <br /> Is system programmed for fail-safe ❑ ❑ � ❑ ❑ � [E]Yes <br /> ❑ ❑ ❑ <br /> shutdown?* IE]Yes N N X yes N N X Yes N N X Yes No <br /> Was fail-safe verified to be ❑ ❑ � ❑ � ❑ <br /> operational?* X❑Yes N N X❑yes N N X❑Yes N N X❑Yes No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min Smin 5min <br /> test: <br /> Test Start Time: 14:2 8 14:2 8 14:04 14:0 4 <br /> Initial Reading(RI): 0 0 0 0 <br /> Test End Time: 14 :4 3 14:4 3 14:19 14:19 <br /> Final Reading(RF): +.0005 +.0019 +.0002" -.0003" <br /> Test Duration: 15min 15min 15min 15min <br /> Change inReading(RF-Rl ): +.0005 +.0019 +.0002" -.0003" <br /> Pass/Fail Threshold or Criteria: +-002" +-002" +-002" <br /> Test Result: Pass Fail o.PassEl Faila PassEl Fail r-7-1 <br /> Pass o Fail <br /> Was sensor removed for testing? aYes No❑NA X Yes[:]No❑NA x Yes[:]No❑NA X Yes[_]No[]N <br /> Was sensor properly replaced and aYesaN ]NA aYes❑Nc]NA aYesaN�NA ayes�No❑[� <br /> verified functional after testing? <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> t If the entire depth of the UDC is not tested,specify how much was tested.If the answer to anv of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />