Laserfiche WebLink
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at hfp://www.swrcb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State ofC'alifomia <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 13, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#32190,MKT 2368 <br /> Bldg. No.: <br /> Site Address: 4943 S.KINGSLEY(FRONTAGE RD)HWY 99 @ ARCH AIRPORT RD <br /> City: STOCKTON Zip: 95206 <br /> Facility Contact Person; MGR-LORENA <br /> Contact Phone No.: 209-939-0679 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 <br /> B.Inventory of Equipment Tested/Certified Date of Testing/Servicing; 5/23/2013 <br /> Check tinea ro nate boxes to indicates cific a u ment ins ected serviced. <br /> Tank IDs T4-RUL <br /> r <br /> nk ID: T5-MUL <br /> W In-Tank Gauging Probe. Model: Ma In-Tank Gau in Probe. MAnnular Space or Vault Sensor. Model: 302 g g Annular Space or Vault Sensor. Model: 302 <br /> W Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s), Model: 208 <br /> r Fill Sump Sensor(s). Model: 208 P-0 Fill Sump Sensor(s). Model: 208 <br /> Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> r Tank Overfill/High-Level Sensor,Model: Flapper r Tank Overfill/High-Level Sensor.Model: Flapper <br /> Others eci equipment a and model in Section E on Pa e 2 . ` Others eci a ui ment a and model in Section E on Pa e 2). <br /> Tank ID: T6-PUL Tank IDs <br /> TP In-Tank Gauging Probe. Model:_Mag r In-Tank Gauging Probe. Model: <br /> ✓ Annular Space or Vault Sensor. Model: 302 <br /> F Annular Space or Vault Sensor. Model: <br /> W Piping Sump/Trench Sensor(s). Model: 208 <br /> Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: 208 <br /> r Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> 170 Electronic Line Leak Detector. Model: Veeder Root PLLD r Electronic Line Leak Detector. Model; <br /> fV_ Tank Overfill/High-Level Sensor.Model:—Flapper r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equip ment type and model in Section E on Pa e 2 . Other Snprifva ui ment a and model m Section E on Pa e 2 . <br /> IDspenser 1/2 Dispenser <br /> IDs 3/4 <br /> r Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: 208 <br /> WO Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> IDspenser 5/6 =� n <br /> r Dispenser Containment Sensor(s).Model: 208f:j ainment Sensor(s).Model: 208 <br /> P Shear Valve(s). .r Dispenser Containment Float(s)and Chaln(s). ainment Floats)and Chain(s). <br /> Dispenser 9/10 Dispenser <br /> IDs IDs 11/12 <br /> r Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: 208 <br /> Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Floats)and Chain{s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; {check all that apply r Sset- <br /> up r Alarm history report em <br /> Technician Name(print): Jason Castillo <br /> Signature: �•- <br /> Certification No.: 842639 License.No.: 743160Class'A' <br /> Testing Company Name: Tanknology Phone No.: (BW)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 <br /> Date of Testing/Servicing: 5/23/2013 <br /> Monitoring System Certification Page I of 3 <br /> 12/07 <br />