Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MOIN-.ITORING PLAN--PAGE Z <br /> VL DISPENSI±R MONITORING <br /> MONITORING OF AREAS BENEATII DISPENSERS)IS PERFrjRNfED USING THE FOLLOWING ME MODS)(Check all that apply) Nilo <br /> ❑ 1.CONTTNUOUS MONITORING OF UNDER DISPENSER CONTAINMENT(UDC) <br /> PANELMANUFACfUREER. Mss. MODEL 4: tsx. <br /> LEAK SENSOR MANUFACTURER. Tia MODEL fl(S)- <br /> WILL DETECTION OF A LEAD IN THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ❑ a YES ❑ b.NO t tss. <br /> WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP Sl TDOWN? ❑ a.YES ❑ b.NO <br /> WILL.FAILURF)DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a.YES ❑ K NO M57- <br /> 2.MECHANICAL COMITNUOS MONITORING(e.g-,FLOAT AND CIIAIN ASSEMBLY)IN UDC TRIPS SIM'AR VALVE IN CASE OF LEAK <br /> MANUFACTURER- rt a MODEL#(S): <br /> M59. <br /> ❑ 3.VISUAL MONITORING DONE: ❑ a DAILY ® b.WEEKLY <br /> 4.NO DISPENSERS <br /> (Specify) <br /> Met. <br /> ❑ 99.OTI3E;IL <br /> VII: ENHANCERLEAK DETECTION <br /> [] I,WE HAVE BEEN NOTIFIED BY THF STATE WATER RESOURCES CONTROL BOARD THAT WE MIDST PERFORM ENHANCED Lia i wta <br /> DETECTION(ELD)FORT HE UST(S)COVERL•D BY THIS PLAN.PER 23 CCR§2644.1,ELD IS PERFORMED EVERY 35 MONTHS AS REQUIRED <br /> VIII. TP-MNING <br /> REFEEN <br /> RCE DOCUMENTS MAINTAINED AT FACILITY(Check all drat apply) M° <br /> 1. 0 TTIIS UNDERGROUND STORAGE TAtv`It;MONITORING PLAN(Required) <br /> 2. ER OFERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) <br /> 3. THE FACILITY'S BEST MANAGEMENT PRACTICES(Required as efJanuary 1,2405) <br /> 4. ❑ CALIFORNIA UN17MGROUND STORAGE TANK REGULATIONS <br /> 5. Q CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> ti. ❑ STA-M WATER RESOURCES CONTROL BOARD (SVIRCB) PUBLICATION: `ITANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. l S WRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br /> 99.© OTHER(Specify): Not.Persoiurl with LIST monitoring sesponst nitres ate tar t al l o the a' ve oLume-nts re evant to r jo duties tart can access acwnents v icn ne xlcd <br /> By January 1,2005,this facility will have a-Designated UST Operator"who has passed the C,:tifb,-=- UST Sytem Operator Exam administered by the In1cmational <br /> Code Council(ICC)_ By July 1,2005,and annually thereafter,the 'Designated LIST Operator"will ill train facility employees in the proper operation and maintenance <br /> of the UST systems.71is training vvill include,but is not limited to,the followin . <br /> Y Opcmation of the USTsystetns in a manner consistent with the facility's best management practices. <br /> The facility employee's role with regsrd to the leak-detection equipment. <br /> D The fsoility employee's role with regard to spills and overfills. <br /> 'r Whom to contact far emergencies and teal:detection alarms.. <br /> For facility employees hired on or after July 1,2005,the initial training will be conducted%within 34 days of the date of hire_ ^^ <br /> IX. COMVIE 'TRA:DDITIONAL INFORMATION <br /> Please use this section to include any additional UST sysmm monitoring-gelated information(e.g.,additional information required by your local agency): a sss. <br /> Type of overfill prevention: Audible,Nisual Alarm <br /> X. TERSONNEL RESPONSISIIJI'I'`IES <br /> AS OF JANUARY 1, 2005. THE `DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION Ill OF THE CURRENT UST OPERATING FERMIT <br /> APPLICATION—FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE:MONITORING ACTIVTITFS AND MAINTAINING <br /> LEAK DE MC71-ION EQUIPMENT COVERED BY IDBS PLAN TITLE 23 CCR§2715(c),ANIS WILL PERFORM AND DOCUMENT MMNIU vi MON-HILY <br /> VISUAL INSPECTIONS OF THE FACILITY'S UST SYSTEMS IN ACCORDANCE WITH TITLE 23 CCR§2715(c). <br /> KI. ONVNERIOPERAT011 SIGNATURE <br /> CERTIFICATION:I eertify that the information provided herein is true and accurate to the best of my knowledge. <br /> O ERATURSIGNA EP9FSENT'TN9 DATE: <br /> Q Owner tM <br /> Operator <br /> O OPERr1TC}RNAME(p��rt): Rt42. OtVNI�tfOPERATORTITLI' <br /> M ency Use Oily) This plan has been reviewed and: Approved ❑Approved With.Conditions ❑I> :hprovd <br /> Local.Agency Sig ahtre: fie" i z -q <br /> Comments/Spxxiai Conditions: <br /> hwxfwvre-d(9/24104)-314 <br />