Laserfiche WebLink
26 A ' SIDE OF OPENING FOR 1" WAYNEVAC <br /> - �V DISP SER 12 1/2" VAPOR RECOVERY OUTLET <br /> 3/4" OPENING FOR 1" BALANCE <br /> NEW WAYNE 2/V580 BLENDING DECAL NOTES; 8 <br /> MULTI-PRODUCT DISPENSER <br /> SINGLE HOSE EACH SIDE INNER SHEATHING DECALS: WAYNE SUPPLIED, VAPOR RECOVERY OUTLET <br /> 42" 32 3/4" INSTALLED BY WAYNE PER MANUFACTURER'S 1" CONDUIT OPENING 3^ ( 3^ <br /> INSTRUCTIONS. (SEE NOTE BELOW) <br /> 1 FUELING INSTRUCTIONS"/"WARNING"/"PRICE INCLUDES" <br /> HOSE RETRACTOR TO 28 20" 0 001-010247-00B BE APPLIED CENTERED ON INNER <br /> RED JACKET MOD N SHEATHING, LEFT SIDE (FACING FROM A SIDE OF <br /> RJ-884-034-5 <br /> (TYP. 2) DISPENSER). BOTTOM OF DECAL IS TWO INCHES (2") a� <br /> ABOVE THE HEAD. <br /> COAXIAL HOSE C MP 28 O "NO SMOKING", "STOP MOTOR" a \ ; O <br /> GOODYEAR MOD 11 <br /> a n1 <br /> -�-� - -- ------ GY-CHC HOSE MP (TYP. Z) ' i�----------�i ' 001-048031 - WILL BE APPLIED CENTERED ON \ Q O <br /> _ _______ INNER SHEATHING, RIGHT SIDE (FACING FROM A SIDE ,n io E •� L M <br /> 0?��C 87 OCTANE i <br /> OF DISPENSER). BOTTOM OF DECAL IS TWO INCHES 92 OCTANE V 0 L <br /> DISPENSER CANOPY TO BE 4" STANDARD FUEL HOSE WHIP 28 4 (2'7 ABOVE THE HEAD. v <br /> INSTALLED BY CONTRACTOR _ GOODYEAR MOD # GY MX48 O "NOZZLE PROBLEMS" "> ° N m <br /> i. <br /> (TYP. 2) 001-921474 - (WITH KISS CUT PHONE NUMBERS). iv \_ a s <br /> 1 CONTRACTOR CHOOSES THE APPROPRIATE PHONE \_ 0 <br /> NU u <br /> FUEL HOSE BREAKAWAY VALVE 5 <br /> NUMBER AND INSTALLS IT ON THE UNIT IN THE SPACE ICY) ,— <br /> a U <br /> 2 "HUSKY" MOD # HS-3360VR 28 PROVIDED ON THE "WARNING" DECAL. I m ® 0 <br /> (TYP. 2) OUTER SHEATHING DECALS: NOT WAYNE SUPPLIED, <br /> INSTALLED BY CONTRACTOR PER MANUFACTURER'S <br /> INSTRUCTIONS. a dl------------ - <br /> ® -SELF SERVE" <br /> 3 6'-0" STANDARD FUEL HOSE 28 .� CONTRACTOR SHALL INSTALL LEFT JUSTIFIED AND 6" <br /> GOODYEAR MOD # GY-MX72 a BELOW THE BOTTOM OF THE DISPENSER CANOPY. 6 1/8" 6 1/8" (4) 3/4" x 1-1/2" (� ,0 N <br /> (TYP 2 ) ONLY TO INSTALL TO THE OUTSIDE MOST DISPENSER SLOTS FOR N (, <br /> 7 OUTER SHEATHING ON EVERY ISLAND. ANCHOR BOLTS .? CO <br /> °® ae zz 2) 1-1/2" SUPPLY UNIONS 10 1/2" 70 1/2" L0 <br /> g PLEASE PULL FORWARD" � <br /> 8 O CONTRACTOR SHALL INSTALL LEFT JUSTIFIED AND 6" 2-7/16' UP FROM BASE) 14 1/2" I 14 1/2" _0 0) O <br /> 27 COAXIAL NOZZLE BELOW THE "SELF SERVE" DECAL. ® — e" <br /> ____-e(FRONT SIDE TYP.) iv © "PUSH TO START" 35" L •V <br /> CONTRACTOR SHALL INSTALL ADJACENT TO SODAN I'n <br /> 8 o BUTTON SELECTORS. <br /> CL <br /> REAR B,> SIDE a N <br /> A OXYGENATED FUELS B WHERE REQUIRED. APPLY TO CD <br /> FAR LEFT OF SODA BUTTONS. (TOP 1/3 OF OF DISPENSER0 o <br /> TK3-4 \ /TK3-4 DISPENSER PER AGENCIES) NOTE: ELECTRICAL PENETRATIONS SHALL ENTER FROM THE // � ' CP <br /> GASOLINE RESISTANT SEALANT ® METER TAGS "A" SIDE OF THE DISPENSER V' <br /> CONCRETE ISLAND 9 -- , AROUND BASE OF DISPENSER (TYP.) O FILTER CHANGE PLAQUE - (INSIDE DISPENSER DOOR) NOTE: PRODUCT PIPING SHALL BE INSTALLED FROM THE "B" r <br /> CONCRETE 6" RAISED SIDE OF DISPENSER TO MATCH UNDER DISPENSER + <br /> DRIVE SLAB CONCRETE ISLAND CONTAINMENT SUMP ORIENTATION. PRODUCT AND <br /> ' 'i • '�"• • ' '� VAPOR RECOVERY INSTALLATION, CONTRACTOR IS Q) <br /> e CONC44 .d d RETE <br /> RESPONSIBLE FOR CORRECT ORIENTATION OF THE _ <br /> d. , -d, <br /> DRIVE SLAB <br /> ° STUB-UP'S TO THE DISPENSER. ANY ADJUSTMENTS OF L_ 0 <br /> e <br /> ° FACING "A" SIDE . a d ' a THE INTERNAL WORKINGS OF THE DISPENSER TO <br /> . < > < d < ACCOMMODATE INCORRECTLY INSTALLED PIPING WILL — <br /> BE AT CONTRACTORS OWN EXPENSE. STUB-UPS FROM 0 <br /> 35" 20" HEADERS MUST MATCH LOCATION SHOWN IN THIS PLAN 0- <br /> TO MATCH DISPENSER'S INTERNAL CONFIGURATION. <br /> PRODUCT CONFIGURATION NOTE: 29" <br /> FOR A SINGLE HOSE PER SIDE MULTI-PRODUCT NOTE: DIMENSIONS SHOWN IN THIS VIEW ARE TO BE USED 0 <br /> NOTE; UNDERGROUND PIPING NOT SHOW14 FOR SIZING UNDER DISPENSER CONTAINMENT AND <br /> DISPENSER AS SHOWN THE UNLEADED 87 OCTANE ON THIS DRAWING. SEE DWG. TK3-3 'i-- —I <br /> GRADE SELECTION BUTTON SHALL ALWAYS BE LOCATED CONCRETE CUTOUT CLEARANCES. <br /> THE THE LEFT SIDE OF THE DISPENSER FOR BOTH SIDES Vista <br /> , <br /> THE "B" SIDE OF THE DISPENSER SHALL BE ALIGNED Wa ne V Ista Series 2/V580 Blending Wayne Vista Series 2/V580 Blending <br /> ®_ <br /> WITH THE UNDER DISPENSER CONTAINMENT SUt�B <br /> PRODUCT AND VAPOR PIPING ENTERS ON THE B SIDE OFM P Electronic DIS e n ser r <br /> THE DISPENSER. CONTRACTOR SHALL BE HELD RESPONSIBLE 8 p A MPD Dispenser Base Dimensions <br /> FOR PROPER ORIENTATION AND INSTALLATION. �'— <br /> NOT TO SCALE: <br /> NOT TO SCALE: U <br /> t}._ L <br /> 24'-0" (3 U) <br /> REF O Q) <br /> ------------------------------� SZ <br /> I i CANOPY EXTENT <br /> (n <br /> MCIL <br /> ' I I I TRAFFIC BOLLARD 4" DIAMETER q40 3'-6" 3 <br /> I 42" HIGH CONCRETE FILLED <br /> U-SHAPED. SEE DETAIL 16 -0 V) � <br /> iI I A ON DWG. TK3-4 (TYP. 4 PLCS.) — — —— 0 , m <br /> DISPENSER LOCATION +- L I o <br /> ' I I "B" IDE "B" IDE I I I i I 4"0 PREFAB BUMPER O 0 -p- o <br /> POST FURNISHED BY ARCO 3�_0^ .— 0 <br /> I I I CONCRETE DRIVE o I 1 G.C. TO FILL W/ CONCRETE — <br /> SLAB EXTENT TYP. G.0 TO FILL WITH ° I I 0 v <br /> 11 I i I I (TYP.) / CONCRETE SLURRY D 7 I I SLURRY AND PAINT WHITE O <br /> r \ AND PAINT WHITE M I I I ISLAND FOM BEYOND n <br /> I I I 1 4 I I SEE 17 — 0 <br /> I I I I I °o I IRs16 I I 3 1/2"0 STANDARD I I Ln T 0 — v <br /> PIC TRAFFIC BOLLARD 3-1 2" DIAMETER in BLACK PIPE, BEND I I I I TK3-4 •U 0 0 <br /> / 41 180' ON A 16 1/4" I T� I\ <br /> 34" HIGH CONCRETE FILLED ( I I ET0 E V to `i <br /> I i l l i U--SHAPED. SEE DETAIL 15 I 41 I I I DRIVE SLA o t� N C <br /> I I I ON DWG. TK3-4 (TYP. 4 PLCS.) I I 16" CONIC. <br /> 1I I I III DRIVE SLAB z 1 I _ I i a <br /> L—A <br /> 6" HIGH 7' O" LONG i I m > 'I •� I' I –III • I I�I—I I—I ea •. ' <br /> I DISPENSER ISLANDTYP. 4 PLC ;.) 39 I m a Q. <br /> SEE DETAIL #17 ON SHEET TK3 `o lI I I ,•, I I $'. . II I ) "4 ( <br /> I r 11 <br /> I 12"x 12"x 12" M �— a . °I III ' <br /> . .. o <br /> 3 1/2" FOOTING N -III I I: •: III- ° I a I R = 6" (TYP.) ci In ai 0 <br /> 2'-5" �— . I I I I j I� I ; .. I rn 2 y o <br /> V <br /> Z Cz x x <br /> 3._ „ I / aN0x ;5d `* o0M <br /> o <br /> INSteel IsanForms <br /> "B" IDE WTT"B" IDE 1= III asUdM <br /> N 0.a ON�MO a <br /> 2�, <br /> SCALE SINGLE WALL FIBERGLASS t: 2 m .o!2 i <br /> VAPOR RECOVERY EADER (TYP.) <br /> '------- ------------ <br /> ---------------------------------- <br /> 2" DOUBLE WALLED FIBERGI SSonsultonT job# <br /> PRODUCT PIPING HEADERS (TYP.) P . I . C .• • E• Bumper Island Bumper Post Details <br /> AR 407_ <br /> master release ate <br /> 8 Hose Product Layout For MPD ' s 5 <br /> Post g"NOT TO SCALE: <br /> NOTE: NOT TO SCALE: project master <br /> exe date drawn by <br /> FINAL DETERMINATION OF # OF PIC NO. DATE REVISIONS BY PROJECT RELEASE '�`� <br /> BY OWNERS ORIENTATION <br /> ENGINEER. <br /> BE MADE PERMIT Filename <br /> 0495TK34 <br /> A 7-17-01 CARL3 EVR <br /> Facility/Project <br /> Product Legend Typical Dispenser ProductBID 6100 <br /> 87 — 87 OCTANE � �EC) UNLEADED Configuration at Fueling Island CONST. sheet name <br /> 89 89 OCTANE EC) UNLEADED PLUS <br /> 92 - 92 OCTANE €EC) UNLEADED PREMIUM ^ T K 3 - 4 <br /> NOT TO SCALE: AS-BUILT <br /> G:\CLIENTS\ARCO\AR1402\TANKS\0495TK34.DWG <br />