My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2300 - Underground Storage Tank Program
>
PR0231785
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 12:46:20 PM
Creation date
11/6/2018 10:18:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231785
PE
2361
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
01
SITE_LOCATION
4445 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4445\PR0231785\COMPLIANCE INFO\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/17/2016 4:41:09 PM
QuestysRecordID
3177280
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EHD 23-01 Rev, 09122/16 <br />Page 3 of 6 <br />FA0003994 PRO231785 SCO01 OV3112018 <br />Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s'gov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />PERSHING GAS FOR LESS <br />Facility Address: <br />4445 N PERSHING AVE, STOCKTON <br />Date: <br />January 31, 2018 <br />UST System Observations <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />o V u R COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V ❑ R ❑ COS <br />322 <br />HSC 25281,6(x) <br />Unburied below grade emergency generator system failed to meet exemption status <br />o V 0 R 0 COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />o V ❑ R n COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R o COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />o V o R ❑ COS <br />326 <br />HSC 25299(x)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V o R o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V o R o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />❑ V o R o COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />0 V o R ❑ COS <br />331 <br />CCR 2630(4) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />o V o R o COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary andler secondary containment net constructed in accordance with the established standards <br />❑ V _ R o COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />p V o R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1964) <br />o V o R o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V 0 R a COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General vinlation <br />o V o R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />105 <br />CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. The monitoring plan indicates that the 87 <br />submersible turbine pump (STP) sump sensor is a 302 sensor, however at the time of inspection the service <br />technician verified that it is a 303 sensor. The monitoring plan must be uploaded to the California Environmental <br />Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the <br />EHD. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />EHD 23-01 Rev, 09122/16 <br />Page 3 of 6 <br />FA0003994 PRO231785 SCO01 OV3112018 <br />Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.