Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 Fast Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.Joov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Cate: <br />PERSHING GAS <br />4445 N PERSHING AVE, STOCKTON <br />January 30, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />111 <br />CCR 2638(x) Fa0ed to test monitoring and leak detection equipment annually. <br />Annual monitoring system certification (MSC) and leak detector testing were last performed on January 30, 2017. <br />At that time, all three line leak detectors failed and the IV1SC testing for sensor out and fail safe were not completed. <br />Testing has not been completed and is more than a month-and-a-half past due. These tests are required once <br />every 12 months. Immediately schedule these tests and provide 48 hours notification to the Environmental Health <br />Department (EHD). Please be aware that a follow up inspection will be charged at our current hourly rate. <br />This is a Class II violation. <br />CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down. <br />114 <br />Annual line tightness testing has not been performed at this facility and positive shut -down was not witnessed for fail <br />safe and sensor out at the time of inspection. Testing has not been completed and is over a month-and-a-half past <br />due. This test is required annually. Immediately schedule this test and provide 48 hours notification to the EHD. <br />Please be aware that a follow up inspection will be charged at our current hourly rate. <br />This is a minor violation <br />115 <br />CCR 2715(x) Failed to inform the EHD of designated operator identification or change within 30 days <br />A new designated operator was hired in January 2017 and notification was not provided to the EHD within 30 days <br />of the change. Any changes shall be reported to the EHD within 30 days. Immediately log into the California <br />Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload the notification identifying all the <br />designated operators for this facility. <br />This is a minor violation. <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />204 <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />CCR 2712(i) Failure to have an approved UST response plan available onsite. <br />205 <br />An approved copy of the response plan was not available for inspection. A copy of these plans shall be accessible <br />on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />CCR 2712 Failure to comply with UST operating permit conditions <br />206 <br />A copy of the UST operating permit was not found on site. A copy of the UST operating permit and all attachments <br />and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br />This is a minor violation_ <br />FAD003994 PR0231785 SCO01 01!3012017 <br />EHD 23-01 Rev. 09/22/16 Page 5 of 7 Underground Storage Tank Program OR <br />