COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2300 - Underground Storage Tank Program
>
PR0231785
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 12:46:20 PM
Creation date
11/6/2018 10:18:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231785
PE
2361
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
01
SITE_LOCATION
4445 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4445\PR0231785\COMPLIANCE INFO\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/17/2016 4:41:09 PM
QuestysRecordID
3177280
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA0003994 PR0231785 SC333 03129/20/7 <br />END 23-01 Rev 09122116 Page 3 of 4 Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax; (209) 468-3433 Web: www.siciov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: Facility Address: Date: <br />PERSHING GAS FOR LESS 4445 N PERSHING AVE, STOCKTON March 29, 2017 <br />UST System Observations <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />- V v R <br />_ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />o V o R <br />❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />o V ❑ R <br />❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />Li V ❑ R <br />❑ V ❑ R <br />ei COS <br />Li COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V ❑ R <br />❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />o V ❑ R <br />❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R <br />❑ COS <br />33Q <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />V R <br />- COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(x)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />u V ❑ R <br />❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V ❑ R <br />❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />c V ❑ R <br />❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0 1 gph test for gravity piping not performed (pre -January 1984) <br />© V i R <br />COS <br />Other Violations <br />2010 <br />See below <br />Unlisted AdministrationlDocumentation violation <br />Unlisted Operations/Maintenance violation <br />o V ❑ R <br />❑ COS <br />2030 <br />See below <br />❑ V o R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R <br />❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS ll, or MINOR - Notice to Comply) <br />Item ## <br />Remarks <br />309 <br />CCR 2636(f)(1) Monitoring in sump f UDC failed to activate an audible and visual alarm or stop the flow product. <br />The Bravo box float and chain for 91 -product in dispenser 3-4 under dispenser containment failed to stop the flow of <br />product at the dispenser when tested. All monitoring equipment shall be maintained to activate an audible and <br />visual alarm or stop the flow of product at the dispenser when it detects a leak. The service technician removed <br />debris from the spill reservoir and verified functionality. This was corrected on site. <br />This is a repeat violation, Class II. <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />The 87 -product spill container failed the one-hour hydrostatic test. All USTs shall be equipped with a spill container <br />that has a minimum capacity of five gallons and a drain valve that allows drainage of the collected spill into the <br />primary container or provide a means to keep the container empty. The service technician discovered that the cap <br />had not been seated properly; the service technician re -seated the cap and the 87 -product spill container passed <br />the one-hour hydrostatic test <br />This was corrected on site. <br />This is a minor violation. <br />319 <br />FA0003994 PR0231785 SC333 03129/20/7 <br />END 23-01 Rev 09122116 Page 3 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.