My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2300 - Underground Storage Tank Program
>
PR0231785
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 12:46:20 PM
Creation date
11/6/2018 10:18:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231785
PE
2361
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
01
SITE_LOCATION
4445 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4445\PR0231785\COMPLIANCE INFO\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/17/2016 4:41:09 PM
QuestysRecordID
3177280
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: Facility Address: Date: <br />PERSHING GAS FOR LESS 14445 N PERSHING AVE, STOCKTON March 29, 2017 <br />Overall Inspection Comments: <br />On site to complete the monitoring system certification (MSC) testing inspection that was initially begun on <br />January 30, 2017. The MSC re -inspection included: <br />Testing the87-product-, 91 -product- and diesel- line leak detectors. All three electronic line leak detectors <br />passed. <br />Testing the float and chains in all three under dispenser containments(UDCs). The 91 -product float and chain <br />in dispenser 3-4 failed initially; the service technician removed debris from the spill reservoir and retested the <br />float and chain and it passed. <br />Testing positive shut down for sensor out; the test passed <br />Testing positive shut down for fail safe; the test passed <br />Visual inspection of under dispenser containment (UDC) 5-6 for leakage; the primary piping leak above the <br />shear valve has been corrected. <br />Testing the87-product-, 91 -product- and diesel -product spill containers. The 87 -spill container failed the <br />one-hour hydrostatic test; the service technician discovered that the cap had not been seated properly. The <br />service technician re -seated the cap and the 87 -product spill container passed the one-hour hydrostatic test. <br />The MSC testing was completed today and the facility is approved to operate. <br />An inspection report was provided to the facility operator listing violations discovered during the MSC testing on <br />January 30, 2017. The MSC testing inspection was completed today, March29, 2017 and a report for today's <br />MSC inspection has been provide to the owner. This inspection report addresses testing completed today; <br />violations from the previous MSC testing still must be addressed. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receiving this inspection report. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE <br />:fYCG Uy. Date: March 29, 2017 <br />Printed Name and Title: <br />Daljit Singh, Owner <br />Inspector: I Inspector Phone: <br />VICKI MCCARTNEY, Senior REHS 1 (209) 468-9852 <br />FA0003994 PR0231785 SC333 03/29/2017 <br />EHD 23-01 Rev. 09!22116 Page 4 of 4 Underground Storage Tank Program 01R <br />
The URL can be used to link to this page
Your browser does not support the video tag.