COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 4 of 5 <br /> 6.PIPING SUMP TESTING <br /> Test Method Developed by © Sump Manufacturer ® Industry Standard O Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used ❑ Pressure ❑ Vacuum ® Hydrostatic <br /> C Other(Specify) <br /> Fest Equipment Used: ]neon TS-STS Equipment Resolution. .0006 <br /> Sump#UE042UOOI Sump# Sump# Sump# <br /> Sump Diameter 38" �. <br /> Sunt De th 41" <br /> Sump Material Fiberglass <br /> Height from Tank Top to Top of 16" <br /> Highest Piping Penetration <br /> Height from Tank Top to Lowest 10" <br /> Electrical Penetration <br /> Condition of sumR prior to testing Good <br /> Portion of Sump Tested(1) 2"above pen <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑ Yes ❑ No ® NA ❑ Yes ❑ No ❑ NA ❑ Ycs [] No O NA ❑ Ycs © No O NA <br /> product and water ?* <br /> Turbine shutdown res use time NA <br /> Is sytern programmed for fail-safe ❑ Ycs ❑ No N NA ❑ Ycs ❑ No ❑ NA ❑ YCS ❑ No ❑ NA d Yes ❑ No ❑ NA <br /> shutdown?* <br /> Was fail-safe verified to be ❑ Yes ❑ No ® NA ❑ Yes ❑ No ❑ NA ❑ Ycs Cl No ❑ NA ❑ Ycs ❑ No ❑ NA <br /> operational?* <br /> Wait time between applying <br /> pressurelvaeuum/water and starting 15 MIN <br /> test <br /> Test Start Time 12:02 PM 12:18 PM <br /> Initial Reading(Ri) 5.2276 5.2271 <br /> Test End Time 12:17 PM 12:33 PM <br /> Final Reading R 5.2270 5.2268 <br /> Test Duration 15 MIN 15 MIN <br /> Chan a in Reading Rf-Ri .0006 .0003 <br /> Pass/Fail Threshold or Criteria .002 <br /> Test Result ® Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Was sensor removed for testing? El Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Ycs ❑ No ❑ NA 0 Ycs © No ❑ NA <br /> Was sensor properly replaced and C YC.s ® No 0 NA © Y" ❑ No ❑ NA Q Yes ❑ No ❑ NA ❑ Yes 0 No ED <br /> verified functional after testing? <br /> Comments include any information on repairs made prior to testing,and recommended follow-ug for failed tests <br /> The sensor was reinstalled to the lowest point but not tested. <br /> (1) If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested.(See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.