My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5 of 5 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed by ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used ❑ Pressure ❑ Vacuum ® Hydrostatic <br /> ❑ Other(Spccify) <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> Fill Sump#Fill Fill Sump#Middle Fill Sump# Fill Sump# <br /> UE042UODI UE042U001 <br /> Sump Diameter: 38" 38" <br /> Surnp Depth: 40.5" 41" <br /> Height from Tank Top to Top of 10" N/A <br /> High tPipink Penetration: <br /> Height from Tank Top to Lowest 8" 14" <br /> Electrical Penetration: <br /> Condition of sum prior to testing: Good Good <br /> Portion of Sump Tested: 2"above an 2"above Collar <br /> Sumv Material: Fiberglass Fiberglass <br /> Wait time between applying 15 min 15 min <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 12:02 pm 12:18 yrn 12:02 pm 12:18 pm <br /> Initial Reading Ri): 2.2099 2.2100 1.3296 1.3291 <br /> Test End Time: 12:17 prn 12:33 pm 12:17 pm 12:33 pm <br /> Final Reading[90.: 2.2099 2.2099 1.3291 1.3286 <br /> "fest Duration: 15 min 15 min 15 min 15 min <br /> Chan a in Reading Rf-Ri : .0000 .0001 .0005 .0005 <br /> Pass/Fail Threshold or Criteria: 002 .002 <br /> Test Result: 0 Pass © Fail 0 Pass ❑ Fail ❑ Pass ❑ Fall ❑ Pass Cl Fall <br /> Is there a sensor in the sump? ® Yes ❑ No 0 Yes ❑ No ❑ Yes © No ❑ Yes ❑ No <br /> Does the sensor alarm when either ❑ Yes ® No ❑ NA ❑ Yea ® No ❑ NA ❑ Yes ❑ No ❑ NA Cl Ycs ❑ No ❑ NA <br /> product or water is detected? <br /> Was sensor removed for testing? 0 Yes ❑ No ❑ NA ® Ycs ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> Was Sensor properly replaced and ❑ Yes IM No 0 NA ❑ Yes ® No ❑ NA ❑ Yes ❑ Nu D NA ❑ Yes C3 No 13 NA <br /> verified functional after testing? <br /> Comments include any information on repairs madeprior to lestinje.and recommended follow-up for failed tests <br /> The sensors were reinstalled to lowest point,but not tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.