Laserfiche WebLink
� ! Y <br /> c� SAN JOAQUIN COUNTY , <br /> �. ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s' ov.or ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> A-7 Axi-A' C' m M 1 Zo 16 <br /> Facility address: UST V l <br /> Product <br /> Facility con Title: \J ) <br /> -Phone,e <br /> Dzz ORA12 - Ar -,9 dt <br /> Monitoring PSI: Piping system: Overfill prevention: Violations: <br /> IT <br /> r 3 � ❑ � udible/+rlsual b� <br /> S Pressurized Kuction ❑Gravity apical ❑Mt-RDetect ❑M2-RPrev ❑M-3 Both <br /> ! L <br /> Inspection type: Designated operator: ICC exp.date: <br /> Pcutine AAonitoring Certification ❑Installation ❑Other. 6S 7� ,rj� W 12-/1/�j <br /> On site Service Technician's name: ICC exj. d pf I Manuifac"tureees training:"'���[[[ <br /> Victor 6 verrQr'v 9017601-1).r � Vp' v <br /> VIOLATIONS V R <br /> Code Section <br /> # <br /> NSC=CA Health&S2fey Code'CCR=CA Code of Regulations;V=Violation; RV=Repeat Violation V <br /> 1 HSC 25284 No permit to operate <br /> Secondary containment:(a)test not performed;(e)test report not submitted within 30 days; (f)test <br /> 2 CCR 2637 notification not provided tot11, ipnmental Health Department(EHD)at least 48 hours prior to <br /> Gond ctin the test ? Jv <br /> 3 CCR 2711 b & c Current Unified Program Consolidated Forms not on file with fhe EHD(Facility and tank form <br /> 4, HSC 25292.2 Current financial responsibility documents not on file with the.EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or approved by the EHD <br /> 6 CCR 2712(i) Monitoring and/or response plan is not onsite , <br /> Maintenance&monitoring records not maintained•3 years,cathodic protection records for 6'/ Will <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs,linings,and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction pipina(pre-January1, 1984 not rformed ist <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 10 CCR 2632(c)CQ Monitoring system is not present in the interstitials ace of a double walled UST/piping Mt <br /> 11 CCR 2630(d) UST monkodng equipm2nt is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (M1) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291 a 2 Secondary containment for UST system is not tight <br /> 16 CCR 2636(p)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a3-gallon per hour leak at 10 psi M1 <br /> 18 CCR 2635(b)(1) Spill container not installed,failed to contain a minimum capacity of five gallons,or failed to (M2) <br /> provide a means to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section M2 <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) M2 <br /> 21 HSC 25291 a Water in 2°containment not removed,analyzed&propedy disposed of <br /> Unauthorized release that: (c)did not escape secondary containment ig cleaned up within eight (mi) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a I CCR 2715(a) Failed to inform the EHD of a chance of designated operator within 30 days <br /> 23b I CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD ins or. Received Idle:EHD Z3-02-002 REV 04#(8110 Page 1 UST OFFICIAL INSPECTION REPORT <br />