My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax.(209)468-3433 Web.www.s' ov.or ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Ins tion Date: <br /> �4 5- /j ., Sooi T�u�l� l •4y13j zolo <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&SafetyCode;CCR=CA Code of Regulations;V=Violation• RV=Re at Violation V <br /> Designated operator monthly inspection:(c)(1)alarms not documented; (c)(2-4)spill containers, <br /> 23c CCR 2715(c), (d), UDCs,and sumps(if necessary)not inspected; (c)(5)required test dates not checked or noted; (c)(6) <br /> (e) employee training not verified;(d)(e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1)not performed;(2)not current for at least one employee <br /> on site; 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair,replacement,calibration,or certification; (f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment component that was certified.re aired or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed Mi <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line tightness test not rformed if positive shutdown or fail safe not present M1 <br /> 28 CCR 2661 Repair for tank or ipinq not tested for tightness within 30 days of completion of the repair <br /> 29 CCR 2643(e) Biennial tightness test of gravity pipingnot performed re-Janus 1 1984 M1 <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed re-Janus 1, 1984 M7 <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained X <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST s tem not obtained <br /> 36 HSC 25299(a)(9) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) I Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 1 CCR 26360(6Emergency enerator monitoring system not checked daily or log not kept M1 <br /> 41 1 HSC 25281.5(b)(3) I Unburied fuel piping not visually inspected at least monthly or log not kept M1 <br /> VPH S stems HSC 25290.2 installed between 07101/03 and 06/30/04 HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(b)and d for a UST system installed after July 1,2004 were not submitted <br /> 43 HSC 25290.1(c)(1) primary containment not liquid or vapor tight <br /> HSC 25290.2(c) 1 <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the <br /> HSC 25290.2(d) entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space <br /> of the UST system not maintained <br /> HSC 25290.10) UST system not tested by one of the following methods prior to use: (1)Enhanced leak detection;(2) <br /> 48 HSC 25290.2(i) inert gas pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Other; See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> EHD inspector: ^ Phone: UIC <br /> t w�f [f� r O Septic system: <br /> � -[ � ❑Serves z24 peoplelday <br /> ReceivTitle: ❑Receives other than sanitary waste <br /> / Other discosal methods_ <br /> CC ❑Dry wells/French Drains <br /> EHD 23-02-002 REV 04MSII0 Page 2 UST OFFICIAL INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.