COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AT& T,345 N. San Joaquin St.,Stockton, CA (SR0058480) <br /> .w. a. Primary piping soap test: One hour pneumatic pressure test at 1100!0 of operating <br /> pressure, or 40 psi, whichever is greater. <br /> b. Secondary piping soap test: One hour pressure test per manufacturer's guidelines. If <br /> there are no manufacturer's guidelines, test shall be performed using an applicable <br /> �. method specified in an industry code or engineering standard. <br /> c. 24-hour hydrostatic test(or equivalent)on piping sump. <br /> d. Secondary containment testing on the new fuel pipe run after installation, and six <br /> months after installation. <br /> 4 e. Submit updated Form B to EHD within 30 days of piping replacement. <br /> f. EHD inspector must be present to witness removal of piping, decontamination of <br /> removed piping, management of the rinsate, and any soil sample collection. <br /> Please be aware that the facility cannot operate the unmonitored portions of the <br /> UST system prior to EHD inspections and approval. <br /> 6w <br /> 4. Since concrete will be broken near the UST and piping, a secondary containment test <br /> must be performed on the UST and piping once concrete is poured in accordance with <br /> the manufacturers guidelines. <br /> how <br /> 5. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> ` following: <br /> a. One of several permissible valid, current contractors licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Tester's license issued to the individual by the State Water Board, and <br /> b. A valid, current California UST Service Technician certificate issued by the <br /> International Code Council (ICC), and <br /> c. A valid, current certificate of training from the manufacturer(s)of the component(s) <br /> 6. being tested, repaired, or serviced. <br /> 6. Qualified installers must possess or work under the direct and personal supervision of an <br /> individual physically present at the work site who possesses all of the following: <br /> ` a. A valid, current contractor's license issued by the Contractors State License Board, <br /> and <br /> b. A valid, current certificate of training from the manufacturer(s)of the component(s) <br /> being installed, and <br /> c. A valid, current UST Installation/Retrofitting certificate issued by the International <br /> Code Council (ICC). <br /> 7. Update and submit a copy of the"UST Monitoring Plan" for EHD approval. An approved <br /> copy will be returned for on site records. <br /> 8. A"UST Certification of Installation/Modification" form shall be submitted by the owner or <br /> the own6,'s agent(CCR Section 2635(4)) before this upgrade is considered complete by <br /> EHD- <br /> 6- <br /> 9. All components must be certified by an independent testing organization and labeled as <br /> required by the organization (UL, ULC, ANSI, API, ASTM, etc.). See California Code of <br /> Regulations(CCR)Title 23, Chapter 16, Table B for a complete list. <br /> 2 <br />