Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department DWECrOR <br /> a600 East Main Street Donna Heran.RENS <br /> Stockton, California 95202-3029 Pxacr:a it Coorrtauv, rows <br /> • Robert MoClelian,RENS <br /> Jeff Carniesoo,RENS,RDi <br /> F o Website:Www.sjgov,orWehd Kasey Foley,RE HS <br /> y 3,2010 Phone: (209)468-3420 <br /> Fax: (209)4464-0136 <br /> Chris Brown � i � <br /> 8 <br /> Stantec Architecture Inc. MAY <br /> 1 8060-M CS$ <br /> 1137 N.McDowell Blvd. <br /> 6- Petaluma,CA 94954 <br /> 6,,,, Re: Pacific Bell Telephone Co.,dba AT&T California SR0058480 <br /> 345 N_San Joaquin St., Stockton, CA <br /> The San Joaquin County Envirorwrientai Health Department(EHD)has reviewed the permit <br /> addendum application dated May 13, 2010(specifically page 2)for the work on the underground <br /> storage tank(UST)system at the above noted address: <br /> - Replace the underground primary fuel supply piping by pulling a new Western <br /> 6- Fiberglass Co-Flex flexible double wall pipe through the existingsecondary piping, <br /> which will then serve as a rockguard chase pipe. <br /> - If secondary containment retest fails,replace the secondary test boots on the vent/return <br /> �.v piping,with contingency to replace the primary and secondary vent/retum piping with <br /> FRP primary and secondary piping,install one firebox where supply pipings enter pump <br /> room and another firebox where vent pipings enter the basement,with a Veeder Root <br /> sensor Model 794380-208 in each firebox. <br /> - Test new piping in accordance to applicable regulations and specifications <br /> - Collect one soil sample every 20 lineal feet of the fuel and vent piping using a hand <br /> auger. The samples will be collected within two feet of the piping at a depth of one to <br /> two feet below the base of the piping. Samples will be submitted to McCampbell <br /> Analytical, Inc.,within 24 hours for diesel,BTEX,and oxygenate analyses. <br /> L <br /> - Triple-rinse and decontaminate the removed piping by inert gas such as nitrogen. <br /> - Rinsate will be hauled by Evergreen Oil,Inc.to be disposed at Ecology Control <br /> Industries. <br /> - Removed piping will be hauled by Ecology Control Industries to be disposed at <br /> Ecology Control Industries. <br /> Perform secondary containment test after installation,and 6 months after installation. <br /> �. <br /> This permit addendum application had been submitted to EH©after the above-mentioned <br /> fireboxes and new Veeder Root sensors Model 794380-208 sensors have been installed. <br /> E <br /> �,. The permit has been approved with the following conditions- <br /> 1. <br /> onditions:1. Contact the local fire department and the San Joaquin Vary Air Pollution Control <br /> i~ <br /> District for any appkaW permits and requirements. <br />