My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> Address:345 N. SAN JOAQUIN STOCKTON 95202 Service Date: 05/13/2010 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 123.01 <br /> Complete the foll owina checklist: <br /> ®Yes ❑No* Is the audible alarm operational? <br /> ®Yes ❑No* Is the visual alarm operational? <br /> ®Yes ❑No* Were all the sensors visually Inspected, functionally tested,and cofirmed operational? <br /> ®Yes ❑No* Were all sensors installed at lowest point of secondary containment and positioned so that other <br /> e ui ment will not interfere with their propgr operation? <br /> ®Yes ❑No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> operational? <br /> ❑N/A <br /> ❑Yes ❑No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> containment monitoring system detects a leak,fails to operate,or is electrically disconnected? <br /> " es'which sensors <br /> initiate positive shut- ❑ Sump/Trench Sensors ❑ Dispenser Containment Sensors <br /> ®NIA down?: <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ❑Yes ❑No <br /> ❑Yes ❑No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> mechanical overfill prevention valve is Installed),is the overfill warning alarm visible and audible at the <br /> ®N/A tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger?: <br /> ❑Yes* ®No Was any monitoring equipment replaced?If yes,identify specific sensors,probes, or other equipment <br /> re laced and list the manufacturer name and model for all replacement parts in Section E,-below. <br /> Was liquid found inside any secondary containment systems designed as dry systems? <br /> ❑Yes' ®No If yes,check the type(s)of liquid found and describe causes In Section E,below. ❑Product ❑Water <br /> ®Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports, if applicable <br /> ®Yes ❑No' i Is all monitoring equipment operational per manufacturer's specifications? <br /> "In Settlon E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments <br /> Other sensors from Page 1: <br /> L3 Middle Sump sensor 794380-208-Certified <br /> L5 Supply/Ret Fire Box sensor 794380-208-Certified <br /> L6 Vent Fire Box sensor 794380-208-Certified <br /> An Overfill Prevention Valve is installed in the drop tube <br /> Monitoring System Certification Page 2 of 4 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.