CAST BOLT IN-PLACE FOR <br /> CMU WALL WHERE TRACER TERMINATION <br /> OCCURS (BY OTHERS <br /> MOUNT PIPING VAULT <br /> EXTERIOR CONCRETE DISCRIMINATING SENSOR <br /> SLAB WITH VEEDER ROOT SHUT-OFF BALL VALVE <br /> \#330020-12 SENSOR (SUPPLY) <br /> THIS 1" DIA. CONDUIT MOUNTING KIT, <br /> HOUSES BOTH 3 OR <br /> MORE CONDUCTOR GENERATOR ROOM CONCRETE <br /> SHIELDED BELDEN SEE VAULT FLOOR SLAB (BY OTHERS <br /> CABLE RUNS TO THE LID DETAIL <br /> VEEDER-ROOT BY WAY <br /> OF THE TANK <br /> 4" x 1" DEBURRED HAND HOLE AT 1/4" STEEL DIAMOND PLATE I ro I TRANSITION TO SCH. 40 <br /> MIDPOINT OF TRENCH END OF PLATE (2) 12 7/8" x 20 3/4" PIECES WESTERN FIBERGLASS 3/4" <br /> • COTCH COATED BLACK STEEL <br /> SUPPLY & i' RETURN <br /> FUEL OIL LINES . PIPE USING 3/4" (SUP.) <br /> 1/4" x 1/2' FLAT BAR, t — — — — — • COUPLING (PI 2570) & <br /> 4" CONTINUOUS Aa ADAPTOR & 1" (RET.) <br /> // COUPLING (PI 3570) <br /> CL & <br /> 8EAR 12 GAUGE COPPER TRACE _ ADAPTOR <br /> u <br /> (TYP.) o MOISTURE BARRIER 4 MIL <br /> • VISQUEEN <br /> 3" WESTERN FIBERGLASS s o e <br /> SECONDARY 4 <br /> / V 1-4 CONTAINMENT PIPE <br /> #4 REBAR x 3" LG 4" SCHEDULE 40 PVC 6• 24• TRANSITION POINT <br /> 1/4"' x 1 1/2" x 1 /2" (2 EACH SIDE) PIPE SLEEVE <br /> ANGLE FRAME 1/8"" SEAL PIPING ANNULUS 1" DUPLEX TEST DONUT WITH <br /> BETWEEN 3" AND 4" 3/4" INSERT <br /> PIPE WITH BOSTIK #1100 <br /> #4 @ 12" BOTH <br /> WAYS <br /> VAULT LID DETAIL <br /> 3 FUEL OIL SUPPLY & RETURN LINES 1 NOT USED SCALE: NONE <br /> PIPING VAULT J-BOX W/SEAL-OFF <br /> DISCRIMINATING PER NEC 514 <br /> SENSOR <br /> 3/4" C. WITH 3 CONDUCTOR — SEE DETAIL 3 <br /> BELDEN SHIELDED CABLE FROM 6" 24 THIS SHEET <br /> PIPING VAULT SENSOR TO <br /> VEEDER-ROOT 1" PVC CONDUIT SLEEVE <br /> 3/4" SCH 40 SCOTCH COATED <br /> BLACK IRON SUPPLY AND 1" L to <br /> RETURN FUEL OIL LINES <br /> o <br /> 0 o1 <br /> I u <br /> I I I <br /> in ALL VENT RISER SUPPORTS TERMINATE VENT LINE WITH IMPACT SAFE <br /> ----- TO BE INSTALLED ABOVE SOLUTIONS TANK BREATHER #T6000. CAP <br /> 7"' CONDUIT WITH 3 CONDUCTOR DIELECTRIC UNION TO BE PLACED 18" MIN. ABOVE ADJACENT <br /> WALL. ROOF, ENCLOSURE OR PER LOCAL <br /> (PIPING VAULT SENSOR) BELDEN ROOF LINE OF STRUCTURE, /FIRE CODE (IMPACT ABSORBENT <br /> SHIELDED CABLES TO TOP OF WALL OR \ TECHNOLOGIES INC (805)466-4709) <br /> DAY TANK VEEDER-ROOT BY WAY OF TANK 12'-0" ABOVE GRADE <br /> SECURE PIPE & CONDUIT TO <br /> 2" SCOTCH COAT SCH. 40 �- BUILDING. ATTACHMENT <br /> BLACK STEEL PIPE VENT �� DETERMINED BY STRUCTURE <br /> RISER SURFACE. <br /> ISSUE DATE# 00-00-00 <br /> CMU BUILDING WALL WHERE DRWG# CLLC##-##-YRMO <br /> OCCURS (BY OTHERS) \ BUILDING SHT Al, Mi, S1 <br /> OR WALL \ ISSUE DATE# 00-00-00 <br /> DRWG# CLLC##-##-YRMO <br /> 2"-150# MALLEABLE SHT# Al, Ml, Sl #### <br /> 5 PIPING VAULT PLAN VIEW IRON COUPLING REVISIONS / AUTHORIZATIONS <br /> WELD 100% <br /> 3" SCH. 40 \ 1/2"-150# MALLEABLE WESTERN FIBERGLASS NO. MVISOMS ARHOFI naFs aTE BY <br /> BULL PLUG \ IRON COUPLING <br /> 3"-150# MALLEABLE \ \1/2" PLUG <br /> IRON COUPLING \ WELD 100% <br /> �— <br /> ���� UPDATED 08/17/00 <br /> PROPRIETARY SBC INFORMATION <br /> NOT FOR GENERgL USE OR DISCLOSURE OUTSIDE OF SgC <br /> GRADE ENVIRONMENTAL MANAGEMENT UNDER EXEMPTIONS SET FORTH IN <br /> CONCRETE THE CALIFORNIA PUBLIC RECORDS ACT. THIS INFORMATION MAY <br /> —5 GALLON SPILL CONTAINER FOOTING ONLY BE USED BY AUTHORIZED PERSONNEL OF THE LOCAL <br /> PHIL-TTE x85100-F WITH GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR <br /> #PP1005TS TRASH BASKET. 3" MNPT x BELL PER g 1 NI THFI IONS FOR BUILDINGS, CONSTRUCTION, <br /> FIBERGLASS ADAPTOR AND OR ZSNNG CH�ES. <br /> FILL CAP & ADAPTER 4" TO TOP <br /> SEAL DRAWINGS PREPARED FOR <br /> #OPW633#638o16T--7085 & 3" FIBERGLASS 2 SCH. 40 SCOTCH COAT <br /> B AGK STEEL PIPE &ID <br /> ENVIRONMENTAL MANAGEMENT <br /> PIPE NIPPLE <br /> "TANK <br /> " 40 SCOTCH COAT PACIFIC REGION <br /> STEEL PIPE 2'" x 24" FEMALE x MALE SWIVEL <br /> STAINLESS BRAID FLEX <br /> �T TITIZ <br /> j RGLASS LINE CONNECTOR. TELEFLEX <br /> 4" SCH. 40 SCOTCH COATED <br /> BLACK STEEL FILL RISER 10" LONG SECONDARY CONTAINMENT FLEX <br /> p I I (FACTORY INSTALLED) BOOT. TELEFLEX OR CONTAIN— <br /> FACTORY THREADS TMENT TECHNOLOGIES <br /> SHEET TTRE <br /> NOTE: FOR OPTIMUM INSTALLATION EMERGENCY GENERATOR SUCTION SYSTEM <br /> S RESULTS MANUFACTURER SUGGESTS <br /> USING ONLY FACTORY THREADED TANIS & PIPING DETAILS <br /> NIPPLE RISERS <br /> F317WTE/ ROUTINE OROF3C <br /> 2 SUMP PENETRATION DETAIL (FLEXIBLE PIPING) DATE: SCATS: 1 <br /> GOWN GNEL ITY. <br /> i��jT ARC�'I'8CM • KNGINIMG • EMONKIWAL SSAVIaS SBC AUTHORIZATION: SHEET: 4 OR 8 SHpfEFM sHeEr No. <br /> 6 SPILL CONTAINER DETAIL 4 TANK VENT RISER DETAIL JOHN"'7 " N�oWEu PETaLOFa CA 9495+ (707) 785-1680 D^ <br /> 0�0M[ QTC JOHN W. JOHNSON, ARCHITECT JAMES H. RAY, CIVIL ENGINEER P4 <br />