COMPLIANCE INFO_2002 TANK TOP SUMP REPLACEMENT PLAN
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2002 TANK TOP SUMP REPLACEMENT PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 2:50:14 PM
Creation date
11/6/2018 12:13:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 TANK TOP SUMP REPLACEMENT PLAN
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\TANK TOP SUMP REPLACEMENT PLAN 2002.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3/4" FUEL OIL SUPPLY NOTES <br /> & 1" FUEL OIL RETURN <br /> 1, ALL UNUSED TANK OPENINGS SHALL BE TIGHTLY SECURED WITH PIPE PLUGS AND SHALL BE COVERED WITH A FIBERGLASS CAP <br /> (HAT) INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS UTILIZING WET RESIN. ANNUALR TO BE AT FILL END (LOW <br /> END) OF TANK. <br /> G 5 15 2. ALL TANK RISERS TO BE FACTORY SCOTCH COAT #206N FUSION BONDED EPDXY COATED SCH. 40 BLACK STEEL PIPE. FIELD <br /> 12 PATCH ALL EXPOSED OR DAMAGED AREAS & FITTINGS WITH SCOTCH #312 COATING. (MATERIAL SUPPLIER: FLETCHER COATING CO. <br /> E FOR MULTIPLE QUANTITY OF TANKS: 714/637-4763. ALL VERTICAL RISER THREADS SHALL BE WRAPPED IN FIBERGLASS 3" MIN. ABOVE EXPOSED THREADS IN <br /> HOLD THIS DIMENSION NOTE: ALL FILL BOXES <br /> A NUMBER TANKS W/3" BRASS ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. <br /> TO ASSURE (5) GALLON TO BE INSTALLED ON NUMBERS SET IN CONCRETE 3. TANKS SHALL BE TESTED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AS WELL AS LOCAL <br /> CAPACITY OF SPILL CENTERLINE OF TANK B ADJACENT TO FILL BOX ORDINANCES. <br /> COLLECTOR C 4. ALL CONTAINMENT BOX ASSEMBLIES SHALL BE FRBERGLASSED TO TANK RING AND MUST BE HYDROSTATIC TESTED. <br /> 5. TANKS TO SLOPE DOWN TOWARD FILL END AND ANNULAR SPACE SENSOR 1/2" MIN., 2" MAX., MEASURED OVER THE LENGTH <br /> ` D El OF TANK. USE TRANSIT TO DETERMINE SLOPE. <br /> v 6. ALL CONDUITS TO HAVE SEAL-OFFS PER LATEST EDITION OF THE NATIONAL ELECTRIC CODE. ALL J-BOXES TO BE EXPLOSION <br /> 2" SCH. 40 BLACK STEEL <br /> J PROOF. KILFILL OX#GRSS-2OR <br /> CON CROUSE-HINDS GLIA SERIES. ORIENT ALL J-BOXES SUCH THAT -SHE SCREW LID IS ACCESSIBLE <br /> PRIMARY & 3" FIBERGLASS WITHIN THE FILL BOX OR CONTAINMENT SUMP. <br /> SECONDARY 7. ALL PENETRATIONS OF THE SUMP BOXES TO BE SEALED BY THE APPROPRIATE SIZE WESTERN FIBERGLASS GROMMET OR <br /> F 73 VENT AMERICAN LINING COMPRESSION FITTING. <br /> H S. USE CABLE CONNECTOR FITTINGS (CROUSE-HINDS CGB OR EQUIVALENT) AT MONITOR & LEVEL GAUGE CABLE CONNECTIONS TO <br /> o PLAN VIEW SHOWS SUGGESTED PIPING J-BOXES & PIPE FITTINGS IN SUMP BOXES. <br /> " 3/4" BALL ORIENTATION. IN ELEVATION VIEW 9. ALL UNDERGROUND CONDUITS AND CONDUITS INSTALLED OUTDOORS TO BE FVC COATED RIGID. ALL CONDUITS INSTALLED INSIDE <br /> VALVE BELOW, SOME PIPING HAS BEEN DELETED BUILDING MAY BE EMT, ALL CONDUIT FITTINGS TO BE COMPRESSION TYPE. <br /> FOR CLARITY <br /> 10. PRIMARY & SECONDARY PIPING FOR VENT LINE TO BE SCH. 40 SCOTCH COATED BLACK STEEL (PRI.) & AMERON DUOLOY 3000L <br /> FIBERGLASS (SEC.). REDUCING BOOT IN CONTAINMENT SUMP TO HAVE TEST PORT. <br /> NOTE: 11. UNDERGROUND PRIMARY AND SECONDARY PIPING FOR FUEL OIL SUPPLY & RETURN LINES TO BE WESTERN FIBERGLASS. <br /> ORIENT 12" ACCESS OPENING IN ITEM 6� BULKHEAD REDUCERS IN CONTAINMENT SUMPS, PIPING VAULTS & TRENCHES TO HAVE TEST PORTS. <br /> 3 q OVER SUMP SENSOR J-BOX. <br /> SUMP SENSOR MUST BE ABLE TO 12. ALL CONCRETE TO BE 6 SACK MIX, 2500 PSI (MIN.) AT 28 DAYS. <br /> ��7 BE EASILY REMOVED VERTICALLY. 13. ALL PIPING TO SLOPE DOWN TO UNDERGROUND TANK 1/8" TO 1/4" PER FOOT MIN. <br /> VIEW VIE YY 14. ALL EQUIPMENT, HARDWARE AND SYSTEM COMPONENTS MUST BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURER'S <br /> INSTRUCTIONS AND SPECIFICATIONS. <br /> 15. INSTALL PRODUCT TAG IN FILL BOX, ATTACHED TO RISER. <br /> SUCTION SYSTEM MATERIAL LIST <br /> IMPORTANT O DOUBLE WALL STEEL, FIBERGLASS COATED COMPOSITE TANK. SEE SITE SPECIFIC <br /> GAUGE PROBE RISER TOP OF LID TO MAINTAIN SLOPE AWAY FROM ALL MANWAY PLAN FOR CAPACITY REQUIRED. MODERN WELDING ENIVRO 16. <br /> TOP EDGE OF COVERS 3" IN 6' OR TO EDGE OF SIAB <br /> ADAPTOR (WHICHEVER IS CLOSER) O TANK & PIPING LEAK MONITOR/ELECTRONIC PRODUCT LEVEL GAUGE CONTROL <br /> BOX WITH GAUGE PROBE & 3 DISCRIMINATING SENSORS. ALL PROBES USED <br /> SET FILL BOX TO ALLOW 11 9 7 8 5 10 (TYR.) i6 6 8 5 SHOULD BE FOR LIQUID DETECTION. VEEDER-ROOT #TLS-350 WITH PRINTER. <br /> ACCESS TO J-BOX LID <br /> FOR LIQUID SENSOR O 1 1/2 DOUBLE POPPET FOOT VALVE -DPW E <br /> � ,- <br /> #4 O 12" O.C. BOTH WAYS OR EMICO A439-005 AND A699-003 <br /> MAINTENANCE <br /> O VENT LINE 4"0"x2" 150# MALLEABLE IRON EXTRACTOR FITTING WITH PLUG. <br /> • . • s' O (2) PIECE CONTAINMENT SUMP WITH FIBERGLASS KIT PHIL-TITE 4FG-4261-S-2 <br /> :2 -- (4' BURY). OTHER BURY DEPTHS MAY REQUIRE DIFFERENT HEIGHT SUMPS. <br /> 36" DIA. MANHOLE. WITH ONE 12" ACCESS COVER PHIL-TITE #TC 3600-TAO <br /> BACKFILL LEVEL r WATERTIGHT SUMP <br /> 2 1/2" THREADED SHIELD ADAPTOR (TYP.) —�� 4 /"`•l� O7 36" CIA. SPILL CONTAINMENT MANHOLE WITH 5 GALLON SPILL BUCKET. <br /> 2" ( YP.) PVC CAP 3/4" C. I 3/4" C. 9 PHIL—mTE #SC-3600—SCA-2 <br /> HAND—TIGHT ONLY <br /> m I I NOTE: O WATERTIGHT SUMP SHIELD ASSEMBLI PHIL-TITE #FG-3433-WTSS INCLUDES <br /> 1" 0. 10" LG. (OR AS NEEDED) SLOPE SIDES OF TANK <br /> TO LEAK MONITOR/LEVEL I FACTORY THREADED HOLE OR USE SHORING #WTC-1300 WTR-1013. WTC-8000 & WTR-0608. INSTALL PER MER. INSTALLATION INSTRUCTIONS <br /> Y g GAUGE CONTROL PANEL. I I NIPPLE, PROVIDED BY G.C. FOR ALL TANK EXCAVATIONS <br /> m (AFTER BUILDING PENETRATION, R ER FROM TANK IN ACCORDANCE WITH CAL/OSHA (D FILL CAP & ADAPTOR, 4" TOP SEAL. OPIN 634-TT-7085 & 633-T-8076 <br /> o _ 3/4' CONDUIT MAY BE USED) 9 CONSTRUCTION SAFETY ORDERS. OR EMICQ WHEATON 097-005 & AA-014 <br /> 2 <br /> w CONCRETE SLAB 2 NOTE: FOR OPTIMUM INSTALLATION 13 10 CONDUIT PENETRATION-SEALING GROMMET. AMERICAN LINING COMPRESSION FTG, <br /> w MUST EXTEND 12" I RESULTS MANUFACTURER SUGGESTS OR WESTERN FIBERGLASS. (MUST WITHSTAND HYDROSTATIC TESTINGI ISSUE DATE# 00-00-00 <br /> PAST EXCAVATION 2" SCH. 40 USING ONLY FACTORY THREADED 2" PLUG IN UNUSED DRWG# CLLC##—##—YRMO <br /> PERIMETER ALL SCOTCH COATED J I NIPPLE RISERS ` ANNULAR 11 18" D'A. X 12" SKIRT LOCKABLE & WATERTIGHT FILL BOX. PHIL-TITE #M1800 SHT Al, M1, Si <br /> AROUND BLACK STEEL PIPE I _ SEE NOTE (1 ) ISSUE DATE# 00-00-00 <br /> 12 BULKHEAD FITTING AND REDUCING BOOT. WESTERN FIBERGLASS DRWG# CLLC##—##—YRMO <br /> I — a - - - - - - 9 — I � O SHT# A1, M1, S1 <br /> I� I 13 2" x 24" FEMALE x MALE SWIVEL STAINLESS BRAID FLEX CONNECTOR REVISIONS AUTHORIZATIONS <br /> 2 DISCRIMINATING N I I I O TITEFLEX 110165-32-0240 <br /> O I 2 O DISCRIMINATING 3 <br /> LOCATED AT N PLUG I I I I SENSORI I 14 4" ALUMINUM DROP TUBE DPW #61 T SERJES N0. WMONS/AUTHORATONS OXIE or <br /> O <br /> SUMP LOW POINT ph I I I I LOCATED AT I II <br /> g I SUMP LOW POINT ( 15 RETURN LINE 4"x4"x2"x2" 150# MALLEABLE IRON EXTRACTOR FITTING WITH <br /> ryry ( O PLUG & 2"x1" 150# MALLEABLE IRON REDUCING BUSHING. MORRISON #560 OR <br /> u L 18 I I 1 1/2" SCH. 40 DPW 233-4422. <br /> 11 I I I BLACK STEEL PIPE 16 EXTRACTOR CAP UNIVERSAL #412 OR EBW 760. <br /> II I N, / I UPDATED 08/17/00 <br /> 137 VENT CAP IMPACT SAFE SQL1JT1oNs TANK BREATHER #Ts000 PROPRIETARY SBC INFORMATION <br /> pp NOT FOR GE•lIERA(_,•U,SE OR DISCLOSURE O�TSIN OF SBC <br /> a OVERFILL VALVE, EMCO WHEATON #A1100 THERCCANLIIFORNIA PUBLICRECORDSACT. THISnINFORMATIOFN MARTHY <br /> ` FILTER FABRIC (WHEN REO•D ONLY BE USED BY AUTHORIZED PERSONNEL OF THE LOCAL <br /> ppbBII GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR <br /> 14 II /��/ WITH UNSTABLE SOIL AND/ 19 UNIVERSAL SENSOR MOUNTING KIT, VEEDER--ROOT #330020-012 ANR TSRANDNT}{QRI]A TS FOR BUILDINGS, CONSTRUCTION, <br /> OR HIGH WATER TABLE AN o ZO G CHAN�GtES <br /> CONDITIONS) <br /> \`� B 7 WESTERN FIBERGLASS MATERIAL LIST (THIS SHEET ONLY) DRAWINGS PREPARED FOR <br /> ////%` COENVIRONMENTAL MANAGEMENT <br /> NOTE: II / <br /> IN CASES WHERE A REFURBISHED TANK 1 O 1" PRIMARY FLEX PIPE - (RETURN LINE) PI 3500 E <br /> IS USED, THE ABOVE FILL BOX DETAIL `\ 45° 2OB 3/4" PRIMARY FLEX PIPE - (SUPPLY LINE) PI 2500 PACIFIC REGION <br /> \ <br /> AND ASSOCIATED NOTES BELOW TAKE 1� <br /> \ PRQIrCf 7171E <br /> PRECEDENCE. i\\ 9 I OC SECONDARY FLEX PIPE PI 4525 <br /> BULKHEAD FITTING AC 8420 <br /> PLUG UNUSED TANK ANNULUS SENSOR ^� x I _ <br /> BE PORT WITH 2" SOLID SQUARE 1" PRIMARY COUPLING PI 3570 <br /> a HEAD PLUG' (SEE NOTE 1) — — — — — — — — — — — — \ O 3/4., PRIMARY COUPLING PI 2570 <br /> 1" <br /> OWN TOWARD FILL END e EF x 1 NET PRIMARY ADAPTOR <br /> _ SLOPE TANK D <br /> 744390-420 O 1/2" MIN., 2" MAX. MEASURED OVER .PEADYAN NQT '$HOWJ FOR CLkTY <br /> \\ LEAK SENSOR LENGTH OF THE TANK OH 3/4" EF x 3/4" NET PRIMARY ADAPTOR SHEET ' <br /> EMERGENCY GENERATOR SUCTION SYSTEM <br /> ____ __ Oi 3/4" x 1" INSERT TANK SECTION SLAB PLAN <br /> III I I -I I I_I I I-I I I_I I <br /> 1=1 I JIII-�I I I-III- I I I�I I I-III—III I ,I I I- III—III—III I I I ,I I I-I I I_,` OJ REDUCING BOOT W/ TEST PORT E9IIIM E/ ROUTINE ORDER: SECTION/ <br /> —iTI—III—' 111— aue swE 1 <br /> NAIL NATIVE CLEAN, WASHED <br /> COMPACTED SAND DRAWN BY. CHECI® BY: <br /> BED AND BACKFILL ARCRTPRLTURB • RNGRiRSRQIG • RMONYBRTAL SMMIGRS Sec A17HORIZA710N. SHEET 3 OF, 8 sHEES ;7Wr NO. <br /> L�I+'� 1137 N. McDOWELL BLVD, PETALUMA, CA 94954 (707) 765-1630 SBC TWIN' NO.:1 TYPICAL TANK PRODUCT SUCTION SYSYTEM SCALE: NONE �fg ONO DWI JOHN W. JOHNSON, ARCHITECT JAMES H. RAY, CIVIL ENGINEER _ P3 <br />