My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1994-2010 (2)
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
239
>
2300 - Underground Storage Tank Program
>
PR0231482
>
COMPLIANCE INFO 1994-2010 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:39:57 PM
Creation date
11/6/2018 2:38:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994-2010
RECORD_ID
PR0231482
PE
2361
FACILITY_ID
FA0000720
FACILITY_NAME
MADSENS SUNRISE DAIRY
STREET_NUMBER
239
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
25927805
CURRENT_STATUS
02
SITE_LOCATION
239 S STOCKTON ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\STOCKTON\239\PR0231482\COMPLIANCE INFO 1994-2010.PDF
QuestysFileName
COMPLIANCE INFO 1994-2010
QuestysRecordDate
9/25/2017 6:59:08 PM
QuestysRecordID
3647880
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[]Check this box if tank gauging is usonly for inventory control. 49 <br /> ®Check this box if no tank gauging or SIR equipment is installed and disregard the following section. <br /> (This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring). <br /> Com lete the following checklist: <br /> ❑Yes ❑ No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br /> ❑Yes ❑ No* Were all tank-gauging probes visually inspected for damage and residue buildup? <br /> El Yes [} No* Was accuracy of system product level readings tested'? <br /> E ❑ No* Was accuracy of system water level readings tested'?❑ No* Were all probes reinstalled properly? <br /> ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> * In the Section H, below, describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors (LLD): <br /> Check this box if LLDs are not installed and disregard the following section. <br /> ❑Yes ❑ No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br /> ❑ NIA (Check all that apply) Simulated leak rate: ❑ 3 g.p.h.; ❑ 0.1 g.p.h ; [10.2 g.p.h. <br /> ❑Yes ❑ ivo* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> ❑Yes ❑ No* Was the testing apparatus properly calibrated? <br /> [�Yes ❑ No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> ❑ N/A <br /> 0 Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br /> 0 N/A <br /> ❑Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> [`] N/A or disconnected'? <br /> ❑ Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system <br /> ❑ NIA malfunctions or fails a test? <br /> G Yes ❑ No* For electronic LLDs,have all accessible wiring; connections been visually inspected? <br /> ❑ N/A <br /> ❑ Yes j ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> * In the Section. H, below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: The "Jack Koffelt Straight Up" safe suction system is self monitoring and testable <br /> only with an overfill tank test. <br />
The URL can be used to link to this page
Your browser does not support the video tag.