My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
I
>
INDUSTRIAL
>
1010
>
2200 - Hazardous Waste Program
>
PR0518741
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2018 11:46:56 AM
Creation date
11/6/2018 8:39:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0518741
PE
2228
FACILITY_ID
FA0010456
FACILITY_NAME
THATCHER COMPANY OF CALIFORNIA INC
STREET_NUMBER
1010
STREET_NAME
INDUSTRIAL
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
17728053
CURRENT_STATUS
01
SITE_LOCATION
1010 INDUSTRIAL DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\I\INDUSTRIAL\1010\PR0518741\COMPLIANCE INFO 1999 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
943
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5)V See kent Miller, Letter dated 8/4/2005- YES Provide local visual and audible alarm for the gas 11/7/2005 <br /> Gas qoom Item No. 3-A continuous gas- room(storage room) <br /> det ion system shall be provided to <br /> de the presence of gas at or below the Provide sensor for treatment system discharge 11/7/2005 <br /> perf zissible exposure limit or ceiling limits. Purchase/ <br /> The detection system shall initiate a local Acquire Sensor <br /> alar,n and transmit a signal to a constantly <br /> atte 7ded control station. The alarm shall be 11/14/2005 <br /> bot visual and audible and shall be Installation <br /> desi 7ned to provide a warning both inside <br /> and outside of the storage area. The <br /> and ble alarm shall be distinct from all <br /> othi r alarms. The gas-detection system <br /> sha be capable of monitoring the room or <br /> ar& in which the gas is stored at or below <br /> the rmissible exposure limit or ceiling <br /> limi and the discharge from the treatment <br /> sys m at or below one-half the IDLH limit. <br /> CFC Sec. 8003 3.1.6 Tie in the sensors for <br /> gas detection in all areas of the gas room <br /> incl ding the sensor for the exhaust <br /> sys m. CFC,sec. 8003.3.1.3.5 <br /> D See Kent Miller, Letter dated 8/4/2005- YES Provide seal gaskets on the man doors, All the 11/7/2005 <br /> Gas Room Item No. 4-Provide seal penetrations in the walls, tie the roll down doors Select <br /> gaskets on the man doors, AN the to the sensors and repair the man door panic Contractor <br /> pen?trations in the walls, provide gas hardware <br /> sen ors to the exhaust, tie the roll down <br /> doo to the sensors and repair the man <br /> doo panic hardware.A negative pressure <br /> mu t be sustained in the gas room. CFC, <br /> Sec 8003.3.13.5 <br /> ote: SJCDA- 5 an Joaquin County District Attomey(David Trey); SJCOES-San Joaquin County Office of Emergency Services (Dennis Fields); <br /> JCEHD- San aquin County Environmental Health Department(Kasey Foley); SFD-Stockton Fire Department(Kent Miller) <br />
The URL can be used to link to this page
Your browser does not support the video tag.