My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
8372
>
2200 - Hazardous Waste Program
>
PR0539709
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2018 1:21:55 PM
Creation date
11/6/2018 8:39:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0539709
PE
2220
FACILITY_ID
FA0017952
FACILITY_NAME
PACIFIC SOUTHWEST IRRIGATION CORP
STREET_NUMBER
8372
Direction
S
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
18308005
CURRENT_STATUS
01
SITE_LOCATION
8372 S JACK TONE RD
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\J\JACK TONE\8372\PR0539709\COMPLIANCE INFO .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
381
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> SECTION V- HEALTH HAZARD DATA <br /> PRIMARY ROUTES <br /> OF ENTRY: X Inhalation X Skin Contact Eye Contact Ingestion <br /> EFFECT OF OVEREXPOSURE <br /> ACUTE: <br /> Inhalation: Exposure to vapors may result in nausea,drowsiness,dizziness,headache,fatigue,other CNS effects and heart arrhythmias(irregular <br /> heart beats).Can cause imitation of eyes and nasal passages. Exposure to high concentrations may impair blood's ability to transport oxyg <br /> Prolonged or repeated exposure to vapors may cause liver and kidney damage. <br /> Skin Contact: Repeated or prolonged contact may result in defatting of skin,imitation,contact ch mtalitis,rash,Itching,swelling. May be absorbed through <br /> skin. <br /> Eve Contact: Direct exposure may result in irritation with comeal or conjuctival inflammation if not removed promptly.Vapors may irritate eyes. <br /> Incitation.. Moderately toxic.Irritant to digestive tract,may induce signs of central nervous system depression. Do not induce vomiting and obtain pro <br /> medical attention. <br /> CHRONIC: <br /> Inhalation $This material is an aspiration hazard and defats the skin.The ingredients are toxic by inhalation and ingestion and may be absorbed throug <br /> the skin.Exposure by these routes may cause central nervous system depression,liver and kidney damage and may sensitize the heart <br /> muscle.Methylene Chloride may interfere with the oxygen carrying capacity of the blood.Methylene Chloride is a possible human cancer <br /> hazard based on test results with laboratory animals.Methylene Chloride has been listed as a potential carcinogen by IARC and NTP. <br /> Methylene Chloride is not believed to pose a measurable risk to man when handled as recommended.Under some circumstances,mutagen! <br /> changes have been observed with Methyl Methacrylate in animal studies.Precautions should be taken to avoid unnecessary exposure to th! <br /> cement. <br /> Inaestion Ingestion of alcohol may increase the potential for development of toxic effects or reactions resulting from Methylene Chloride exposure. <br /> REPRODUCTIVE EFFECTS TERATOGENICITY MUTAGENICITY EMBRYOTOXICITY SENSITIZATION TO PRODUCT SYNERGISTIC PRODUCTS <br /> N.AP. POSS. N.AP. POSS. N.AP. N.AV. <br /> MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE:This material may aggravate an existing dermatitis. Individuals with pre-existing diseases of the heart, <br /> liver or kidney may have increased susceptibility to the toxicity of excessive exposures. <br /> EMERGENCY AND FIRST AID PROCEDURES <br /> Inhalation: Remove patient to fresh air and if breathing stopped,give artificial respiration. If breathing is difficult,give oxygen. Contact physician <br /> immediately. <br /> Eye Contact: Immediately flush eyes with flowing water for 15 minutes and contact a physician. <br /> Skin Contact: Wash skin with soap and water. Remove contaminated clothing and shoes. Launder clothing before reuse. If imitation develops,get medic <br /> attention. <br /> Give 1 or 2 glasses of water or milk. Do not induce vomiting. Call physician or poison control center immediately. <br /> SECTION VI - REACTIVITY <br /> STABILITY UNSTABLE CONDITIONS TO AVOID: Stable under normal conditions of storage and handling. Avoid contact or e <br /> STABLE % posture to fire heats arks electric arcs open flame and hot surfaces which can cause thermal decomposition. <br /> INCOMPATIBILITY <br /> MATERIALS TO AVOID Strong alkalies oxygen,nitrogen,peroxide, otassium and reactive metals. <br /> HAZARDOUS DECOMPOSITION PRODUCTS <br /> This oroduct elves out carbon monoxide CO carbon dioxide CO' Phos ene gas and smoke upon combustion or contact with reactive metals. <br /> HAZARDOUS MAY OCCUR CONDITIONS TO AVOID <br /> POLYMERIZATION I WILL NOT OCCUR X Keep away from heats arks open flame and other sources of ignition. <br /> SECTION VII -SPILL OR LEAK PROCEDURES <br /> STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED <br /> Evacuate area,ventilate and avoid breathing vapors.Dike area to contain spill.Clean up area(wear protective equipment)by mopping or with absorbent material <br /> and place in closed containers for disposal.Avoid contaminatipn of ground and surface waters.Do not flush to sewer.If spill occurs indoors,turn off <br /> heating and/or air conditioning systems to prevent vapors from contaminating entire building. <br /> WASTE DISPOSAL METHOD <br /> Recovered liquids may be sent to a licensed reclaimer or incineration facility. Contaminated material must be disposed of in a permitted solid waste management facil <br /> Follow local State and Federal regulations.Material should not be allowed to drain into domestic sewer or storm drains. Consult disposal expert. <br /> SECTION VIII -SPECIAL PROTECTION INFORMATION <br /> RESPIRATORY PROTECTION(Specify type) <br /> Atmospheric levels should be maintained below established exposure limits contained in Section It.If airborne concentrations exceed those limits,use of a NIOSH <br /> approved positive-pressure,full-facepiece SCBA or positive-pressure,full-facepiece supplied air respirator(with an auxiliary positive pressure SCBA)is recommended. <br /> Even for emergency and other conditions where short term exposure guidelines may/may not be exceeded,use of an approved positive pressure self-contained <br /> breathing apparatus SCBA is recommended. <br /> VENTILATION <br /> Use only with adequate ventilation.Do not use in close quarters or confined spaces. Open doors and/or windows to ensure airflow and air changes.Use local exhaust <br /> ventilation to remove airborne contaminants from employee breathing zone and to keep contaminants below 25 ppm TWA. Use only explosion-prop(ventilation equipm <br /> Monitoring should be performed to determine exposure level s IAW in accordance wlth 29 CFR 1910.1052. <br /> PROTECTIVE GLOVES PVA coated or Latex-Nitrile rubber for dipping/ EYE PROTECTION Splashproof chemical goggles,face shield,safety glasses <br /> immersion. Surgical gloves or solvent resistant barrier creme should provide (spectacles)with brow guards and side shields,etc.as appropriate for exposure. <br /> adequate protection in normal adhesive bonding usage. <br /> OTHER PROTECTIVE EQUIPMENT AND HYGIENIC PRACTICES <br /> Impervious apron and a source of running water to flush or wash the eyes and skin in case of contact. <br /> SECTION IX -SPECIAL PRECAUTIONS <br /> PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING <br /> Store in a shaded place between 40°F - 110°F(5°C-43.7'C). Keep away from all sources of heat,sparks,open flame and other sources of ignition.Close container <br /> after each use. Use with adequate ventilation.Avoid contact with eyes,skin and clothing.Train employees on all special handling procedures before they work with thi <br /> product. <br /> OTHER PRECAUTIONS <br /> Follow all precautionary information given on container label,product bulletins and our solvent cementing literature.All material handling equipment should be <br /> alectrically orounded. <br /> The information contained herein is based on date considered accrete.However,no warranty is expressed or implied regarding the accuracy of Ibis data or the results to be obtained from the use <br /> thereof ii <br /> 0d-T-04 <br />
The URL can be used to link to this page
Your browser does not support the video tag.