My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4715
>
2200 - Hazardous Waste Program
>
PR0514152
>
COMPLIANCE INFO 2002 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 11:11:57 AM
Creation date
11/6/2018 8:41:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2015
RECORD_ID
PR0514152
PE
2228
FACILITY_ID
FA0010067
FACILITY_NAME
JIFFY LUBE #2497
STREET_NUMBER
4715
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437012
CURRENT_STATUS
01
SITE_LOCATION
4715 N WEST LN
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\W\WEST\4715\PR0514152\COMPLIANCE INFO 2002 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
259
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> m <br /> N <br /> OD <br /> Table 1 —Assessment of Used Oil Tank System �'�(,`w W <br /> Jiffy Lube Store #2497, Stockton, CA <br /> a <br /> Citation Requirement Assessment Findings <br /> Section 68265.193. (1)constructed of or lined with materials that are compatible with the (1)The wells and floor of the basement,which comprise the 4F <br /> Containment and waste(s) to be placed in the tank system and shall have sufficient secondary containment system, are constructed of epoxy-coated <br /> Detection of strength and thickness to prevent failure due to pressure gradients concrete,which is compatible with the oil products stored in the m <br /> Releases. (Including static head and external hydrological forces), physical contact tank.The containment system is not expected to fail due to 'Q <br /> (continued) with the waste to which they are exposed, climatic conditions, the stress A <br /> pressure gradients or contact with the waste material. Climatic `v <br /> of installation, and the stress of daily operation(Including stresses from conditions and the circumstances of daily operation will not • <br /> nearby vehicular traffic); impact the containment system due to its location at the facility. <br /> (2)placed on a foundation or base capable of providing support to the (2) The tank is installed in the basement of the store. The shell is <br /> secondary containment system and resistance to pressure gradients mounted on a concrete foundation,which is capable of providing <br /> above and below the system and capable of preventing failure due to support to the secondary containment system, resistance to <br /> settlement, compression, or uplift; pressure gradients below the system, and capable of preventing <br /> failure due to settlement,compression,or uplift.There are no <br /> pressure gradients from above the system. <br /> (3) provided with a leak detection system that is designed and operated (3) Leak detection is described in§66266.192(k)(4), <br /> so that it will detect the failure of either the primary and secondary <br /> containment structure or any release of hazardous waste or accumulated <br /> liquid in the secondary containment system within 24 hours, or at the <br /> earliest practicable time if the existing detection technology or site <br /> conditions will not allow detection of a release within 24 hours; <br /> (4) sloped or otherwise designed or operated to drain and remove liquids (4)Any spilled oil would pool near the tank,and would be visible <br /> resulting from leaks,spills,or precipitation. Spilled or leaked waste and during an Inspection. Spilled waste would be detected within 24 o <br /> accumulated precipitation shall be removed from the secondary hours as a result of the daily inspection, and would be removed n <br /> containment system within 24 hours, or in as timely a manner as is from the interstitial space in a timely manner. <br /> possible to prevent harm to human health or the environment, if removal <br /> of the released waste or accumulated precipitation cannot be <br /> w <br /> accomplished within 24 hour;. <br /> —• r. <br /> z0mlC <br /> `ID <br /> nLID <br /> n v <br /> a <br /> ®, is <br /> J ill cNi <br /> �� UI ■ <br /> g. <br /> is <br />
The URL can be used to link to this page
Your browser does not support the video tag.