Laserfiche WebLink
0 <br /> m <br /> N <br /> OD <br /> Table 1 —Assessment of Used Oil Tank System �'�(,`w W <br /> Jiffy Lube Store #2497, Stockton, CA <br /> a <br /> Citation Requirement Assessment Findings <br /> Section 68265.193. (1)constructed of or lined with materials that are compatible with the (1)The wells and floor of the basement,which comprise the 4F <br /> Containment and waste(s) to be placed in the tank system and shall have sufficient secondary containment system, are constructed of epoxy-coated <br /> Detection of strength and thickness to prevent failure due to pressure gradients concrete,which is compatible with the oil products stored in the m <br /> Releases. (Including static head and external hydrological forces), physical contact tank.The containment system is not expected to fail due to 'Q <br /> (continued) with the waste to which they are exposed, climatic conditions, the stress A <br /> pressure gradients or contact with the waste material. Climatic `v <br /> of installation, and the stress of daily operation(Including stresses from conditions and the circumstances of daily operation will not • <br /> nearby vehicular traffic); impact the containment system due to its location at the facility. <br /> (2)placed on a foundation or base capable of providing support to the (2) The tank is installed in the basement of the store. The shell is <br /> secondary containment system and resistance to pressure gradients mounted on a concrete foundation,which is capable of providing <br /> above and below the system and capable of preventing failure due to support to the secondary containment system, resistance to <br /> settlement, compression, or uplift; pressure gradients below the system, and capable of preventing <br /> failure due to settlement,compression,or uplift.There are no <br /> pressure gradients from above the system. <br /> (3) provided with a leak detection system that is designed and operated (3) Leak detection is described in§66266.192(k)(4), <br /> so that it will detect the failure of either the primary and secondary <br /> containment structure or any release of hazardous waste or accumulated <br /> liquid in the secondary containment system within 24 hours, or at the <br /> earliest practicable time if the existing detection technology or site <br /> conditions will not allow detection of a release within 24 hours; <br /> (4) sloped or otherwise designed or operated to drain and remove liquids (4)Any spilled oil would pool near the tank,and would be visible <br /> resulting from leaks,spills,or precipitation. Spilled or leaked waste and during an Inspection. Spilled waste would be detected within 24 o <br /> accumulated precipitation shall be removed from the secondary hours as a result of the daily inspection, and would be removed n <br /> containment system within 24 hours, or in as timely a manner as is from the interstitial space in a timely manner. <br /> possible to prevent harm to human health or the environment, if removal <br /> of the released waste or accumulated precipitation cannot be <br /> w <br /> accomplished within 24 hour;. <br /> —• r. <br /> z0mlC <br /> `ID <br /> nLID <br /> n v <br /> a <br /> ®, is <br /> J ill cNi <br /> �� UI ■ <br /> g. <br /> is <br />