Laserfiche WebLink
0 <br /> m <br /> N <br /> W <br /> Ul <br /> Table 1 - Assessment of Used Oil Tank System Aro/H W <br /> Jiffy Lube Store #2497, Stockton, CA <br /> Citation Requirement Assessment Findings <br /> Section 66265.192. (1) The assessment specified in subsection(k)of this section is not Not applicable as this installation does not constitute <br /> Design and required for the replacement of the following identical or functionally replacement of functionally equivalent parts or components of <br /> Installation of New equivalent tank system parts or components the types listed In subsection(1). m <br /> Tank Systems and (1)pumps(same type and capacity); a <br /> Components. (2) plumbing or piping components such as unions, elbows, tees <br /> (continued) and gaskets; • <br /> (3)valves and check valves; <br /> (4)piping and valve hangers and supports; <br /> (m) Replacement of identical or functionally equivalent tank system parts Not applicable as this certification does not involve the <br /> or components not listed in subsection (n of this section shall be replacement of previously-certified components, <br /> approved by the CUPA prior to replacement or changeout. <br /> Section 66266.193. (a) In order to prevent the release of hazardous waste or hazardous The tank meets the requirements of this section. See specific <br /> Containment and constituents to the environment, secondary containment that meets the requirements below. <br /> Detection of requirements of this section shall be provided(except as provided in <br /> Releases. subsections(f)and(g)of this section): ... <br /> (b) Secondary containment systems shall be: <br /> (1) designed, installed, and operated to prevent any migration of wastes (1) Secondary containment is provided by the basement of the <br /> or accumulated liquid out of the system to the soil, ground water, or store,which has no drains or other outlets. This will be sufficient <br /> surface water at any time during the use of the tank system;and to prevent any migration of wastes or accumulated liquid out of <br /> the system to the soil, groundwater, or surface water, No <br /> <o <br /> (2)capable of detecting and collecting releases and accumulated liquids (2)The secondary containment system will hold any released N <br /> until the collected material is removed. materials. Leak detection is described in §66265.192(k)(4). <br /> rn <br /> (c)To meet the requirements of subsection(b)of this section, secondary r' <br /> containment systems shall be at a minimum: <br /> o <br /> a I� G �• <br />