Laserfiche WebLink
0 <br /> N <br /> W <br /> Table 1 - Assessment of Used Oil Tank System aCOM <br /> Jiffy Lube Store #2497, Stockton, CA <br /> is <br /> a <br /> Citation Requirement Assessment Findings <br /> Section 66265.192. (C)description of tank system piping(material, diameter); (2)(C) Used oil drains from the collection pans by gravity through <br /> Design and a rubber hose, which connects to steel piping leading to the <br /> Installation of Now tank.A separate pipe drains each of the two collection pans, and <br /> Tank Systems and the two pipes combine at a fitting connected to the tank. <br /> Components. N <br /> (continued) <br /> V <br /> (D)description of any internal and external pumps: and (2)(D) There are no pumps associated with the tank. Oil flows to <br /> the tank by gravity,and Is removed by a vacuum truck. is <br /> (E)sketch or drawing of tank including dimensions. (2)(E)A drawing of the tank is included as Figure 1. <br /> (3)documented age of the tank system (If tank was previously used), if (3) The age of the tank is unknown. It has been in operation for <br /> available, (otherwise, an estimate of the age); at least tan years. <br /> (4)description and evaluation of any leak detection equipment; (4) Broadbase conducts daily inspections of the tank on all days <br /> when personnel are present at the facility. The portion of the <br /> facility containing the tank is occupied routinely. <br /> (5)description and evaluation of any corrosion protection equipment, (5) The tank does not contact water or soil, so engineered <br /> devices, or material; corrosion protection is not required. <br /> N <br /> (6) description and evaluation of any spill prevention or overfill (6) On August 22, 2014,AECOM installed an audible and visible <br /> equipment; high-level alarm, designed to trigger once the level in the Inner • <br /> tank reaches 90 percent of the tank's capacity. The alarm is to <br /> be tested monthly. <br /> w <br /> (7)description and evaluation of secondary containment for the tank (7) The tank is located below grade in the store basement,which <br /> system (secondary containment must meet minimum standards as has no drains. Therefore, the basement provides secondary <br /> specified in subsections (j)(1)through 0)(3)of this section) Including containment for the tank contents, and for the cgrying <br /> applicable secondary containment for ancillary equipment as required in hoses/piping. <br /> subsection 66265.193(f); <br /> i m v <br /> 00 <br /> -6 Ill o <br />