4715
>
2200 - Hazardous Waste Program
>
PR0514152
>
COMPLIANCE INFO 2002 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 11:11:57 AM
Creation date
11/6/2018 8:41:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2015
RECORD_ID
PR0514152
PE
2228
FACILITY_ID
FA0010067
FACILITY_NAME
JIFFY LUBE #2497
STREET_NUMBER
4715
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437012
CURRENT_STATUS
01
SITE_LOCATION
4715 N WEST LN
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\W\WEST\4715\PR0514152\COMPLIANCE INFO 2002 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
259
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> m <br /> N <br /> 00 <br /> Table 1 - Assessment of Used Oil Tank System A COM W <br /> Jiffy Lube Store #2497, Stockton, CA to <br /> Citation Requirement Assessment Findings <br /> Section 66265.192. (8) hazardous characteristics of the waste(s) that have been or will be (8)The waste is used oil,with the characteristic of toxicity. ` <br /> Design and handled; <br /> Installation of New <br /> a <br /> Tank Systems and m <br /> N <br /> Components. � <br /> (continued) <br /> (9) prior to placing a new tank system or component in use, an (9) No documented inspection was conducted at the time the <br /> independent, qualified installation inspector or an independent,qualified, tank was installed.A visual inspection of the tank system was <br /> professional engineer, registered in California,either of whom is trained conducted as required in§66265.192(b), <br /> and experienced in the proper installation of tank systems,shall inspect <br /> the system or component for the presence of any of the following items <br /> and document in writing the results of the inspection: <br /> (A)weld cracks or breaks; <br /> (B)scrapes of protective coatings; <br /> (C) corrosion; <br /> (D)any structural damage or inadequate construction or installation such <br /> as cracks, punctures, damaged fittings.AN discrepancies shall be <br /> documented in the assessment and remedied before the tank system is <br /> placed in use. <br /> (10) all new tanks and ancillary equipment shall be tested for tightness (10) Tank tightness was discussed above, at§66265.192(d), <br /> prior to being placed in use. The results of the test(s)shall be <br /> documented in the assessment.Tank system integrity or leak test o <br /> requirements must be in compliance with all local requirements. Prior to <br /> conducting a tank system integrity test or leak test,contact local agency N <br /> staff for local requirements. <br /> rn <br /> 11 estimated remaining service life of the tanks stem based on <br /> ( ) g y (11) Based an the facility experience of no failures since <br /> findings of subsections(k)(1)through (k)(10). installation one year ago, the service life Is estimated to be at <br /> least 5 years.After 5 years, the tank must be re-certified.At that <br /> time, the remaining service life will be re-evaluated. <br /> I it <br /> o <br /> cq:B m <br /> c0 e <br /> -7 nLCrr <br /> Z 00 <br /> 11Z o �q{ <br />
The URL can be used to link to this page
Your browser does not support the video tag.