My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002 - 2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2002 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:27:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2008
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\18754\PR0507164\COMPLIANCE INFO 2002 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2008
QuestysRecordDate
1/17/2017 5:26:41 PM
QuestysRecordID
3312375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />SWRCB, January 2002 FINAL DRAFT <br />4 TANK ANNCiLAR <br />Page 2 of 7 <br />ar, li\V <br />Test Method Developed By: ❑ Tank Manufacturer Industry Standard ❑ Professional Engineer <br />❑ Other (Spec fi) <br />I cnt ivtctoou iJseu.❑Pressure l__I Vacuum H::d ostatic <br />❑ Other (Spec) <br />Test Equipment Used: Equipment ,; ;soluttvn: <br />— Tank # Tank #1j Tank # Tank # —� <br />Is Tank Exempt From Testing?l <br />❑Yes No <br />❑Yes Na ❑Yes ❑No ❑Yes ❑No <br />Tank Capacity: <br />Tank Material: <br />Tank Manufacturer: <br />Product Stored: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (Rt): <br />Test End Time: <br />d G <br />63 e' <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -Rt): <br />Pass/Fail Threshold or Criteria: <br />Test Result <br />[Pass ❑Fail <br />0 -Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br />Was sensor removed for testing? <br />❑Tes ❑No ❑NA <br />BYes ❑No [INA ❑Yes ❑No ❑NA ❑yes ❑No ❑NA <br />Was sensor property replaced and <br />verified functional after testing? <br />es ❑No ❑NA <br />1:1 -Yes ❑No ❑NA ❑Yes ❑No `INA ❑ ❑Yes No ❑NA <br />Comments — Occlude information on repairs made_ prior to testing, and rermm�ren led fol/ow-t!r ;_ •failed tes!s,t <br />Secondary containment systems Nchere the continuous monitoring automatically monitors both the primary and secondary <br />CNIW iit,:nent, such as systems that arc h'Wrostaticai'y monitored or under constant vacuum, are e\entpt from periodic containment <br />Ming. (Cahf)rnia Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.