COMPLIANCE INFO_2002 - 2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2002 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:27:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2008
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\18754\PR0507164\COMPLIANCE INFO 2002 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2008
QuestysRecordDate
1/17/2017 5:26:41 PM
QuestysRecordID
3312375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUNDSTORAGETANK <br />MONITORING PLAN — PAGE 2 <br />VI. DISPENSER MONITORING <br />MONITORING OF AREAS BENEATHDISPENSER(S) IS PERFOILA]ED USING TIIL F0LL0%i ING AIE I IlOD(S) (Check all that apply) pl5o <br />❑ L CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT (UDC) <br />LS M52. <br />PANEL MANUFACTURER: HfPf ,-Wr M51. MODEL #: TLS <br />LEAK SENSOR MANUFACTURER: klaqode5i I p ZOvv M53. MODEL #(S): Lb 7 Pbj v M54. <br />WILL DETECTION OF A LEAK INTO THE C TRIGGER AUDIBLE AND VISUAL ALARMS? YES ❑ b. NO M55. <br />10-a. <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? 9 a. YES ❑ b. NO Mss <br />WILL FAILURE/DISCONNECTTON OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? [�ra. YES ❑ b. NO M57, <br />❑ 2. MECHANICAL ASSEMBLY (e.g„ FLOATn AND CHgJ,I_N ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER: /hjdu LYf eQ GL Mse. MODEL #(S): UQy�(h1u 11),�6ZIJe.-M" <br />El3.VISUAL MONITORING DONE: [�a. DAILY ❑ b. WEEKLY (R,nirwageaaro rwaJ) Mso. <br />❑ 4. NO DISPENSERS <br />❑ 99. OTHER (Specify) 5151 <br />VII. ENHANCED LEAK DETECTION <br />. WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL. BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M-0 <br />DETECTION (ELD) FOR THE UST(S) COVERED BY THIS PLAN. PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />II. TRAINING <br />RFFLIRENCE DOCUbO{N'FS MAINTAINED AT FACILITY (Check all that appl)) M80. <br />1. THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2. OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) <br />3. THE FACILITY'S BEST MANAGEMENT PRACTICES (Required as of 1/0(/2005) <br />4. CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" <br />7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br />99. ❑ OTIIHR (Specify): 1,181. <br />Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to theirjob duties and can access those documents when needed. <br />By January I, 2005 this facility will have a"Designated UST Operator" -who -has passed the operator exam administered by the International Code Council (ICC). By <br />January 1, 2005, and annually thereafter, the "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systema. <br />This training will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br />➢ The facility employee's role with regard to the leak detection equipment. <br />➢ The facility employee's role with regard to spills and overfills. <br />➢ Whom to contact for emergencies and leak detection alarms. <br />For facility employees hired on or after January 1, 2005, the initial Irainine gill be conducted within 30 days of the date of hire. <br />IX. COMMENTS/ADDITIONAL INFORMATION <br />i tl onimi lodla111 Idda,o,,all91 sastem moniuning-rclatal in Cornmtion (ag., nddilional ivfonnaliom required by your tical agency): 1185 <br />'�an* 'll <br />c�) oY�✓ �/evtVl�iot� : 9S `� fhu� ofi� /=/R� [/ v� L(JG 1 n <br />tJ((7 Cloos OU�rG� 41AfiWt <br />X. PERSONNEL RESPONSIBILITIES <br />AS OF U 05, THE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION III OP 'CITE CURRENT USI OPERATING PER\IIT APPLICA'HON - <br />FACILITY FOW WILL HAVE UL'IENIATE AU'IIIORITY FOR PERFORMING 1111- MDNI1'4121NG AC'11 Al lllI S :ANIJ MAIN I AIN'ING LE.1K DE'I'ECfION <br />EQUIPNIF I' O.'FRED BY IIIIS PLAN, AND \\ ILL PERFOR-M AND DOUL NU NI MINIM[ NI NION'1'IILI' V IM AL 1NSP1 CIIONS 01: IIIb: F:ACE.I'l Y'S <br />UST SYS"F:MCC ORDAN('I. A71'fH 23 CCR § 2715(6). <br />IN <br />Xi. OWNER/OPERATOR SIGNATURE <br />CERT; FTC: <br />F I cerfify that the information provided herein is true and accurate to the best of my knowledge. <br />OW ' <br />OF <br />KA GNA'IURE REPRESENTING <br />DATE: M91. <br />Owner M90. <br />0 S <br />Operator <br />OWNE RATOR (print): 11,192. <br />- OWNER/OPERATOR TITLE: Mss <br />(Agency Use Only) This plan has Len reviewed and: ❑ App rored ❑ Approved With Conditions ❑ Disapproved <br />Local Agency Signature: Date: <br />Comments/Special Conditions: <br />SJCEHD-d (07/03) - 3/4 <br />07/23/03 <br />