COMPLIANCE INFO_2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
8203
>
2300 - Underground Storage Tank Program
>
PR0231595
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:32:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0231595
PE
2361
FACILITY_ID
FA0003591
FACILITY_NAME
JOHN M RISHWAIN
STREET_NUMBER
8203
Direction
E
STREET_NAME
STATE ROUTE 26
City
STOCKTON
Zip
95215-9536
APN
10114021
CURRENT_STATUS
02
SITE_LOCATION
8203 E HWY 26
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\8203\PR0231595\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ak <br />F-1 <br />NW qW <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: Facility Address: Date: <br />JAMES MICHAEL & ASSOC 8203 E HWY 26 STOCKTON June 26 2015 <br />ItePW Remarks <br />309 <br />CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />Unable to determine if sensors activate an audible and visual alarm or stops the flow of product at the dispensers when <br />tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of product <br />at the dispenser when it detects a leak. Correct immediately by having a properly licensed, trained, and certified <br />contractor replace the failed component with a functional component (LG 113-x listed, if applicable) and obtain a <br />permit within one business day from the EHD. If the failed component can't be replaced immediately, there is a <br />possibility that the UST system may be red tagged to prevent fuel inputs. <br />This is a repeat violation, Class II. <br />310 <br />CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product. <br />Unable to determine if sensors activate an audible and visual alarm when tested to ensure continuous monitoring of <br />the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow <br />of product at the dispenser when it detects a leak. Correct immediately by having a properly licensed, trained, and <br />certified contractor replace the failed component with a functional component (LG 113-x listed, if applicable) and obtain <br />a permit within one business day from the EHD. If the failed component can't be replaced immediately, there is a <br />possibility that the UST system may be red tagged to prevent fuel inputs. <br />This is a repeat violation, Class Il. <br />323 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />Unable to determine if line leak detectors are capable of detecting a leak at 3 -gallons per hour at 10 psi. All line leak <br />detectors shall be capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, <br />trained, and certified contractor repair or replace the failed leak detectors (LG 113-x listed, if applicable) and obtain a <br />permit within one business day from the EHD. If the failed leak detectors can't be replaced immediately, there is a <br />possibility that the UST system may be red tagged to prevent fuel inputs. <br />This is a repeat violation, Class II. <br />326 <br />CCR 2635(b)(2) Overfill prevention system not present, was overridden, or failed to meet overfill requirements. <br />Unable to determine if the overfill prevention system is functional. Immediately discontinue deposition of petroleum <br />into this tank until the component is repaired or replaced by a properly licensed, trained, and certified contractor under <br />permit and inspection of the EHD. If the failed component can't be replaced immediately, there is a possibility that the <br />UST system may be red tagged to prevent fuel inputs. <br />This is a repeat violation, Class II. <br />Received by <br />Inspector: <br />Phone: <br />Date: <br />(initial):` -h 6,,A'4' <br />I CINDY VO, EH Specialist <br />(209) 468-8257 <br />06/26/2015 <br />Page 9 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.