My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
8203
>
2300 - Underground Storage Tank Program
>
PR0231595
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:32:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0231595
PE
2361
FACILITY_ID
FA0003591
FACILITY_NAME
JOHN M RISHWAIN
STREET_NUMBER
8203
Direction
E
STREET_NAME
STATE ROUTE 26
City
STOCKTON
Zip
95215-9536
APN
10114021
CURRENT_STATUS
02
SITE_LOCATION
8203 E HWY 26
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\8203\PR0231595\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd <br />CONTINUATION FORM <br />Page: 6 of 6 <br />OFFICIAL INSPECTION REPORT <br />Date: 06/26/14 <br />Facility Address: 8203 East Highway 26, Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to comply) <br />303. Unable to determine if the sump sensors were located to detect a leak at the earliest opportunity. <br />Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. <br />Immediately contact EHD to schedule an inspection to verify the sensors are to the lowest point of the <br />sump. <br />305. Unable to determine if the sensors activate an audible and visual alarm or stops the flow of product <br />when tested to ensure continuous monitoring of the tank system. All monitoring equipment shall be <br />maintained to activate an audible and visual alarm or stop the flow of product at the dispenser when it <br />detects a leak. Immediately have a properly licensed, trained, and certified contractor to verify the <br />sensors are capable of detecting a leak and activating an audible and visual alarm or stops the flow of <br />product under EHD inspection. <br />311. Unable to determine if the line leak detectors are capable of detecting a leak. All line leak detectors <br />shall be capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, <br />trained, and certified contractor to verify the leak detectors are capable of detecting a a 3 -gallon per hour <br />leak at 10 psi under EHD inspection. <br />314. Unable to determine if the ATG, enunciator, and exterior light used as the overfill prevention system <br />is currently functional on the USTs. Each UST shall be equipped with an overfill prevention system. <br />Immediately have a properly licensed, trained, and certified contractor to verify the functionality of the <br />existing overfill prevention system under EHD inspection. <br />315. Monitoring, remote or on-site, is not provided due to illegal abandonment of the UST system. <br />Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. <br />Immediately begin monitoring of the UST system and contact EHD to schedule an inspection for <br />verification. <br />999. HSC 25404 (e)(4). California Environmental Reporting System (CERS) submittal requirement has <br />not been met. <br />NOTES: Conducted routine inspection and took photos from outside the facility building on public <br />grounds. Based on Parcel Viewer, Property/Tank owner remains the same as referenced in this report. <br />The sign listing ERS Global Realty Services for Greg Somerville at 209-649-9080 and 209-474-9000 <br />observed last year has been removed. Facility remains closed, the dispensers tied down, and the <br />exterior emergency shutoff switch pressed on. Audible alarm heard last year from outside the building is <br />silent this year. No Monitoring Certification was conducted this year. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Jeffrey Wong (209) 468-0335 <br />Recceiyed By,: n j <br />(4" c lQp�- O -A �} Z ( <br />Title: <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.