My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
8203
>
2300 - Underground Storage Tank Program
>
PR0231595
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:32:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0231595
PE
2361
FACILITY_ID
FA0003591
FACILITY_NAME
JOHN M RISHWAIN
STREET_NUMBER
8203
Direction
E
STREET_NAME
STATE ROUTE 26
City
STOCKTON
Zip
95215-9536
APN
10114021
CURRENT_STATUS
02
SITE_LOCATION
8203 E HWY 26
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\8203\PR0231595\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />CONTINUATION FORM <br />Page: 5 of 6 <br />OFFICIAL INSPECTION REPORT <br />Date: 06/26/14 <br />Facility Address: 8203 East Highway 26, Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />(continued from Page 4) <br />sumps, and any tank top sump that had an alarm for which there is no record of a service visit, check <br />that all required testing and maintenance for the UST system have been completed and document the <br />dates they were done, and verify that all facility employees have been trained. Immediately ensure that <br />designated operators performing monthly inspections at this facility are including all of the required <br />information on the reports. <br />205. Unable to determine if the designated operator monthly inspection reports since the last EHD <br />routine inspection on August 29, 2008 were retained on site. Designated operator monthly inspection <br />reports for the previous twelve months shall be retained on site. Immediately locate and ensure that <br />copies of the all missing designated operator monthly inspection reports since August 29, 2008 are <br />maintained on site. Submit copies to the EHD. <br />206. Unable to determine if the designated operator employee training was performed. The designated <br />operator shall train facility employees for which he or she is responsible in the proper operation and <br />maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Immediately ensure that employees have been trained by the designated operator, maintain the list on <br />site. <br />301. UST system is currently not being monitored to prevent unauthorized release. The underground <br />storage tank system shall be operated to prevent unauthorized releases. Immediately begin operating <br />UST system that will prevent unauthorized releases. <br />302 & 304. Unable to determine if annular sensors detecting a leak from primary to secondary <br />containment and activates an audible and visual alarm and, therefore, the tanks are not monitored. The <br />interstitial space shall be monitored with a monitoring system connected to an audible and visual alarm <br />system. Immediately contact a properly licensed, trained, and certified contractor to verify if the <br />monitoring system is capable of detecting a leak from primary to secondary containment and activating <br />an audible and visual alarm under permit and inspection of the EHD. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received By: , <br />Title: <br />Jeffrey Wong (209) 468-0335 <br />U) Cnlz lk <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.