CLIENT: <br /> OPTIONAL MANUFACTURER 14 OPTIONAL MANUFACTURER 14 ® NOTES: UST INSTALLATION bp <br /> SUPPLIED 18'x8"x14' DEADMAN SUPPLIED 18"x8"x18' DEADMAN --- -- 14'-9„ <br /> (TYP. OF 4) (TYP. OF 2) <br /> OF TANK O1 SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. <br /> OFIBER REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br /> CONCRETE. <br /> O REINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" FROM <br /> 21 SURFACE. <br /> /\ REINFORCE CONCRETE SLAB AROUND MANHOLE WITH (4) #4 REBAR 60" IN <br /> LENGTH. PLACE REBAR 6" FROM SIDES OF BOX. <br /> SINGLE 1" CONDUIT TO EACH SUBMERSIBLE PUMP. PROVIDE SEAL-OFF AT <br /> OSUMP & BUILDING WIRING TROUGH. CONTAINS LINE VOLTAGE WIRING. ALL <br /> 8" 8" CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED CONDUIT <br /> 25 , 000 GALLON CAPACITY ol 'Ad <br /> �� ,7 ONLY. <br /> r 8" 8" <br /> 22" DIA. MANWAY ONE 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. <br /> mo 0 >N FOR STANDARD MONITORING DEVICES, LOOP CONTAINMENT SUMP <br /> z F' 42" DIA. FILL SUMP ° o� 48" DIA. TURBINE SUMP SENSORS, PLLD, VAC SENSORS & TANK GAUGE TO TANK INTERSTITIAL ' <br /> g O SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL-OFFS IN <br /> BRINE RESERVOIR TANK GAUGE BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO <br /> AND INTERSTITIAL LOCATION INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN ARCO o d MONITOR CO ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL CONDUIT PENETRATIONS H <br /> C3 _ x " MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. <br /> 00 <br /> BP WEST COAST PRODUCTS,LLC <br /> ® ® USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN /" <br /> O0 �® 7 & MAX OF /" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. ALL <br /> ANCHOR STRAP 14 + + " ® SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S & OWNER'S FIELD <br /> LOCATION (TYP.) ® ® ® / REPRESENTATIVE. G H q�! <br /> TANK WEIGHT 8O NOT USED. v <br /> 1 1 ,800 LBS DRY <br /> w w w O NOT USED. <br /> 14,600 LBS W/BRINE <br /> Q. TANK PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST ° <br /> 10 COVER THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR PROPER n <br /> TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING INTO TANK. 2 2 <br /> 11 CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE CORNERS 4? <br /> [ILILLEIIE', oo_LILLUL _E f-E- O WHERE MEETING CONCRETE. <rG ENG <br /> REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS & NUMBER OF H �N <br /> PRODUCT LINES (1 OR 2 PER UST SUMP). <br /> LTURBINE AND FILL SIDE SUMP CONFIGURATION SHOWN IS TYPICAL. FOR 18215 72ND AVENUE SOUTH <br /> 1OSPECIFIC DESIGN CRITERIA AT THESE SUMPS SEE ACCOMPANYING TANK KENT, WA 98032 <br /> INSTALLATION SITE PLAN & SUMP DETAIL DRAWINGS NOTED ABOVE. (425)251-6222 <br /> (425)251-8782 FAX <br /> TANK ANCHORING OPTIONAL. CONSULT LOCAL REGULATION; VERIFY WITH <br /> 14 <br /> OWNER'S REPRESENTATIVE. CIVIL ENGINEERING, LAND PLANNING, <br /> OVERFLOW PROTECTION: UST OVERFLOW COMPLIANCE IS ACHIEVED BY USE OF SURVEYING, ENVIRONMENTAL SERVICES <br /> _ 47'-6 OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT 95% AND IS IN <br /> NO. DATE REVISION DESCRIPTION <br /> 1 ACCORDANCE WITH FEDERAL AND STATE GUIDELINES FOR UST OVERFILL <br /> REQUIREMENTS. i 9-6-16 PERMIT SUBMITTAL <br /> AN OVERFILL ALARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER ROOT 2 12-14-16 PERMIT RESUBMITTAL <br /> UNDERGROUND TANK PLAN VIEW AUTOMATIC TANK GAUGE SYSTEM. THE MONITORING SYSTEM PROVIDES AN 3 1-31-17 PERMIT RESUBMITTAL <br /> AUDIBLE AND VISUAL ALARM WHEN THE TANK(S) ARE FILLED TO THE 90% <br /> SCALE: 1/2" = 1 '-0" A B G H LEVEL 4 6-16-17 CONSTRUCTION RELEASE <br /> A <br /> M.5.3.16 M.5..3.16 3 1 M.5.3.12 M.5.3.12 M.5.3.12 M.5.3.12 O Emn <br /> M.5.3.16 XX INDICATES ITEMS FOUND ON MATERIALS LIST SHEETS M.5.3.01 & M.5.3.02 / 11-14-17 REV. FOR CONSTRUCTION <br /> @7" CONCRETE SLAB AT D <br /> 7" THICK CONCRETE SLAB <br /> 1 1 51.5' 87.6 LB/CF Q <br /> 2 3 1 Q <br /> ASPHALT AND STONE PER G 6" WIDE DETECTABLE (TYP ) 3 4 NOTE: 0 _ <br /> PROJECT SPECIFICATIONS M.5.3.1s - UNDERGROUND MARKING - CHOSE APPLICABLE DRAWINGS FOR (1) 4.0' DIA. <br /> TAPE BURIED 6"-12" BELOW CONFIGURATION SEAL• <br /> 10 11 (TYP.) FINISHED - (TYP.) SUMPIA. <br /> 31 <br /> MAGNATEC <br /> 8. #aM 43e e e MIN 0 4 <br /> 1 RpfESSlONq <br /> 3 3 <br /> 7 <br /> -= DEPTH HA <br /> 2 4' <br /> 4. <br /> COVER <br /> �, P. GR <br /> TANK I L UBB <br /> 1" COND. LOOP TO SUMP 18 18910.5' DIA. 67 4 A <br /> 3" PEA GRAVEL MIN. TO �+ <br /> J-BOX ' ( TOETOPTOF TANK11,800a I 11,800 LBS 4 COLUMN VEL <br /> 4" FRP RISER TO 2" INSIDE 3" DOUBLE " r I I \Q <br /> GRADE 166 WALL FRP VACUUM o = 5 .67' X 1.5' X C V 1 L �� <br /> CROSSOVER TO FILL 1241" FRP BONDED in m 46.0' F OF <br /> DUAL FLOAT HYDROSTATIC I SUMP FOR VENT & ENTRY FITTING DEADMAN CA>r ti U <br /> MONITORING SENSOR 0 6 _ VAPOR CONTINUOUS O (TYP.) ( x <br /> MONITORING <br /> HOME RUN TOO -- O <br /> BUILDING I 13'-6" 12" a <br /> HYDROSTATIC 1" FRP BONDED 1" FRP BONDEDa <br /> RESERVOIR ENTRY FITTING ENTRY FITTING 34 - - BUOYANCY CALCULATIONS <br /> {TIP.) <br /> (TYP.) Z <br /> -- -- D <br /> CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br /> TANK WITH SPHERICAL ENDS, 10.5' O.A. DIAM. (10' NOMINAL) a <br /> 0 <br /> TANK LENGTH: 47' 6-3/4" TANK DIAMETER 10'-6" <br /> TRY 46'-0" DEADMAN, EACH SIDE, 18" WIDE X 8" HIGH o <br /> \ EMPTY TANK UPLIFT = 25,431 GAL. o <br /> \\ = 3,399 CU FT DEVELOPMENT INFORMATION: <br /> 7 <br /> 3,399 CU FT X 62.4BS/CF = 212,097 LBS(DISPLACE WATE ARCO NTI g <br /> /SLOPE SIDES OF TANK HOLE OR \\ 20 <br /> USE SHORING FOR ALL TANK TANK SUMP UPLIFT = (1) X 3.14 X 2.0'2X 4' = 50.24 CU FT MODIFIED <br /> EXCAVATIONS IN ACCORDANCE WITH I \� + (1) X 3.14 X 1.75'2X 4'= 38.46 CU FT 3000 am/pm <br /> OSHA 1926 SUBPART P, OSHA 9E R TO FI INCN 88. m <br /> P\\ 70 CU FT <br /> STANDARDS - EXCAVATIONS; FINAL ( 88.70 CF X 62.4 LBS/CU FT = 5,535 LBS (DISPLACED WATER) W/ 26'x65' CAR WASH <br /> RULE OCTOBER 1, 1989 I ,1 d o <br /> TOTAL TANK UPLIFT = 212,097 LBS + 5,535 LBS = 217.632 LBS FUEL CANOPY w/ 8 MPD's <br /> NK LEV L UGE / I HOLD DOWN CALCULATION <br /> OVERFILL PROTECTION DROP 0 05 S `` SITE ADDRESS: <br /> FL AT IT. OVER LL �I <br /> BACKFILL WITH PEAGRAVE TUBE SET AT 95% 49 5 <br /> 0 TANK SLAB: .58' X 13.5' X 51.5' = 403.0 CU FT E <br /> II 7 PER TANK MANUFACTURE (TYP.) R AT 90,� CAPA'111' a <br /> SPECIFICATIONS. (TYP.) I II 403.0 CU FT X 87.6 LBS/CU FT = 35.302 LBS TRINITY PARKWAY 17, <br /> CUBED BACKFILL ABOVE TANK: Q SCOTT CREEK DRIVE o <br /> /� 4' X 10.5' X 47.5' = 1,995 CU FT - 88.70 CU FT = 1,9Q6.3 C STOCKTON,CA <br /> L ( /\\/ 1,906.3 CU FT X 57.6 LBS/ CU FT = 109.802 LBS 3 <br /> CURVED BACKFILL ABOVE TANK: FACILITY # TBD <br /> j\� 3.14X5.25'2X47.5' = 4,110.9 CU FT <br /> \\/�\ z 12"x12"x11GA STEEL STRIKER PLATES TYP. � X / 10.5' X 10.5' X 47.5' = 5,236.8 CU FT DESIGNED BY: ALUANCE Z&DM: N <br /> �� UNDER ALL OPENINGS W/0 MANWAYS ON a 12°x24"xt1GA STEEL STRIKER PLATES TIP. \ \\ 5,236.8 CU FT - 4,110.9 CU FT = 1125.9 CU FT --- ----- <br /> //\\//\ O g // // / 2 - 562.9 CU FT CHECKED BY: BP REPM: <br /> FIBERGLASS TANK (BY TANK MANE.) UNDER ALL OPENINGS W/ MANWAYS ON \\/\\ o <br /> \\�\ zg \\ w FIBERGLASS TANK (BY TANK MANF.) n �� /j�/ 562.9 CU FT X 57.6 LBS/ CU FT = 32.423 LBS I DRAWN BY: ALU <br /> o ANGE PM: <br /> 2 <br /> m �� __ _ \j\\j ® GRAVEL COLUMN ABOVE DEADMEN: Ln <br /> VERSION: PROJECT NO: <br /> L_ CL // \\/�\\//� 1.5' X14.5' X46.0' X2 = 2,001 CU FT o <br /> j�\jam\ } - - - _ _ \ \�// 2,001 CU FT X 57.6 LBS/ CU FT 115,257 LES 16700 0 <br /> " \/ CONCRETE OEADMEN: + DRA G <br /> t'-0" MIN. PEA GRAVEL b q \ \ � <br /> N <br /> :°••• m:. .°:. ..:. <br /> \ .67' X 1.5' X <br /> 7 <br /> INSTALLED <br /> .. 46 0' 46.2 CU FT <br /> 0 <br /> VER <br /> TYPICAL 2 <br /> C 25,000 GALLON <br /> n. <br /> w. b.. <br /> w;• tl. <br /> a:. <br /> O <br /> \ E SCREEN 109 \ - l <br /> ... .. :.. .. • � :.. -. :. •. :.. •. :. •,• � , :.. •. � 62 CU FTX87.6 LBS CU FTX 2 - 8.099 LBS <br /> COMPACTED SOIL .. .. ... :. � -:. •. •:.. •. •:. •.• •=. •:.: •, •:. •:.: -. •:. ... .. ... ... .. .�•P `r " •.:po- \ \ / O a <br /> TANK SHALL BE SET DEAD LEVEL '`��'Pm':.•'n. w• ... .. ... ... .. ... .. .. `'.•,';;.„•..,. //\/\ 4 DOUBLE WALL FIBERGLASS TANK »� <br /> \ \ / 0 i <br /> \ \ \ \ \ <br /> \ \ \ \ \ \ \ \ <br /> \ \ \ \ \ \ DRY WEIGHT F o <br /> / \ \ \ \ \ \ \ \ ' \ G 0 TANK: INSTALLATION <br /> / / / / / / / / / / / / / / / / / / / / / / / \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \p\° t 1.800 LBS S ALLATION DETAILS <br /> / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / p\ \ \ \ \ \ \ \ <br /> \ / / / / / / / / / / / / / / / / / / / // // // // // // // // // // // // // / / / / / / / / / / / / / / / / / / // //•, <br /> \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ 5 <br /> \��\�\ �\\�\\��\�\ \\/� /� /.\ /� \ /\/\\/.\/\\�\\/� / ✓/,�// / /,-� /\//✓i /\�/�\//\//.\//\�/\�/\\//`/ ./i�//./ /i✓/✓n //�//�\�/\�/.\//.\�/\�/\\//`/� . /i�//,,/% ,. /i/i�/i /, //i�//�,// //i,///,�///,//�,//�\//////// ///// ��///// TOTAL HOLD DOWN: 312.683 LBS s <br /> NATIVE VIRGIN \\' '`\\/\/ \/ \\ \ SHEET NO: <br /> 2' MIN. END OF TANK SOIL END OF TANK TOTAL HOLD DOWN: 312.683 LBS = 1,43 SAFETY FACTOR E <br /> TANK SIZE VARIES WITH MANUFACTURER AND MODEL NUMBER 2' MIN. TOTAL TANK UPLIFT: 217,632 LBS o <br /> 0 <br /> ,0 A: UNDERGROUND TANK SECTION DETAIL <br /> KUM <br /> SCALE: 1/2" = 1 '-0" BUOYANCY CALC. 25,000 GAL. TANK <br /> a <br />