Laserfiche WebLink
CLIENT: <br /> -- by <br /> Z� INTRINSICALLY- SAFE AREA <br /> CASHIER DIESEL <br /> TURBINE SUMP (SLAVE) <br /> AREA UNLEADED dl ' <br /> REGULARGROUND 0 p p . <br /> B,D,E.F,F <br /> TURBINE SUMP 0 <br /> VEEDER ROOT 0 0 1- 5- <br /> TLS-350 LEAK o NEMA 3R JUNCTION BOX 8 _ <br /> DETECTION MONITOR (TYP.) MINIMUM 16" SQ. 2_ 6 <br /> PWR IS B,D,E,F,F,F B,C,E 1 " C. (3) BELDEN CABLE 88760 4-- 8- <br /> 1° C.- \ MODULE TYPE: SMART SENSORS <br /> (6) BELDEN POSITION RECORD: ISO DISPENSER SENSORS <br /> CABLE 88760 FILL SUMP 1 - DISPENSER 15/16 FLOW 5- SPARE <br /> 7 <br /> ��-- --� 2- SPARE 6 SPARE <br /> FILL SUMP 3-- SPARE 7- SPARE <br /> 3 4- SPARE 8- SPARE <br /> MODULE TYPE: SMART SENSORS <br /> B,C,E POSITION RECORD: ISD DISPENSER SENSORS ���� <br /> 000 6 1- SITE VAPOR PRESSURE SENSOR 5- DISPENSER 7 8 FLOW <br /> FILL SUMP 2- DISPENSER 1/2 FLOW 6- DISPENSER 9/10 FLOW <br /> 0 0 3- DISPENSER 3Z4 FLOW 7- DISPENSER 11/12 FLOW BP WEST COAST PRODUCTS,LLC <br /> 1 " C, (6) BELDEN CABLE 88760 B,C,E 4- DISPENSER 5 6 FLOW 8- DISPENSER 13/14 FLOW <br /> 1" C, (6) BELDEN CABLE 88760 1 " C. (3) BELDEN CABLE 88760 MODULE TYPE: SMART SENSORS VACUUM w ' PRESS. rr q <br /> 1 " C, (7) BELDEN CABLE 88760 A <br /> 1 -. ULR 1 PRODUCT LINE 5- DIESEL VENT LINE <br /> 0 TURBINE SUMP (MASTER) 5 2-- ULR 1 VENT LINE 6- ULP PRODUCT LINE <br /> 3- VAPOR LINE LOCATED IN ULR 1 7- ULP VENT LINE <br /> A 4- DIESEL PRODUCT LINE 8- AMBIENT CONDITION SENSOR W <br /> 0 1" C. (5) BELDEN CABLE 88760 MODULE TYPE: INTERSTITIAL SENSOR INTERFACE <br /> POSITION RECORD: UDC SENSORS STACKED, 2 PER CHANNEL <br /> A HYDROSTATIC RESERVOIR 4 DISPENSER 5/6 SUMP & HYDROSTATIC 5-DISPENSER 13/14 SUMP & HYDROSTATIC <br /> 2- DISPENSER 7 8 SUMP & HYDROSTATIC 6-DISPENSER 15/16 SUMP & HYDROSTATIC 2s <br /> UNLEADED 3- DISPENSER 9 10 SUMP & HYDROSTATIC 7-VENT TRANSITION SUMP & HYDROSTATIC <br /> \P R E M I U M/ 4- DISPENSER 11/12 SUMP & HYDROSTATICG ENG� <br /> 8-SPARE <br /> _�/ MODULE TYPE: INTERSTITIAL SENSOR INTERFACE <br /> (1) 1 C, (1) BELDEN CABLE 88760 CROUSE-HINDS EYS POSITION RECORD: TANK SUMP SENSORS STACKED, 2 PER CHANNEL <br /> (SEAL-OFF) OR EQUAL. HYDROSTATIC RESERVOIR1 - ULR 1 TURBINE SUMP & HYDROSTATIC 5- DIESEL TURBINE SUMP & HYDROSTATIC 18215 72ND AVENUE SOUTH <br /> (1) 1 " C, W/ PULL ROPE B,E (NP') 3 2-ULR 1 FILL SUMP & HYDROSTATIC 6-DIESEL FILL SUMP & HYDROSTATIC KENT, WA <br /> 3- ULP TURBINE SUMP & HYDROSTATIC 7-DISPENSER 1/2 SUMP & HYDROSTATIC <br /> 4-ULP FILL SUMP & HYDROSTATIC 8-DISPENSER 3/4 SUMP & HYDROSTATIC (425)25511-6222 <br /> 98032 <br /> SEE TANK FUELING SITE PLAN FOR SPECIFIC TANK LAYOUT MODULE TYPE: PROBE INTERFACE INIERSIRIAL SENSOR COMBO. MODULE (425)251-8782 FAX <br /> VENT STACK W/ VENT POSITION RECORD: TANK LEVEL GAUGES I ANNULAR CIVIL ENGINEERING, LAND PLANNING, <br /> TRANSITION SUMP A — SENSOR IN HYDROSTATIC RESERVOIR (ANNULAR SPACE OF TANKS) 2 1- ULR 1 ATG 1- ULR 1 TANK ANNULAR SURVEYING, ENVIRONMENTAL SERVICES <br /> 2- ULP ATG 2- DIESEL ULP TANK ANNULAR <br /> B — STANDARD LIQUID SENSOR IN TURBINE/FILL/VENT SUMPS 3- DIESEL 3- SPARE NO. DATE REVISION DESCRIPTION <br /> C — TANK LEVEL GAUGE IN FILL SUMP SPARE 4- SPARE s-s-,s PERMIT SUBMITTAL <br /> MODULE TYPE PLLD INTERFACE MODULE <br /> D — PRESSURIZED LINE LEAK DETECTOR IN TURBINE SUMP (PLLD) POSITION RECORD: TURBINE PLLD 2 12-14-16 PERMIT RESUBMITTAL <br /> Tank monitoring Conduit Schematic h ema t i c 1-ULR 1 5- SPARE 3 1-31-17 PERMIT RESUBMITTAL <br /> E — SENSOR IN SUMP HYDROSTATIC RESERVOIR <br /> F — VACUUM SENSOR IN TANK SUMP (AUNULAR SPACE OF PRODUCT LINE) 2-DLP 6- SPARE 6-16-17 CONSTRUCTION RELEASE <br /> 3-DIESEL 4 <br /> SCALE: N.T.S. <br /> 4-SPARE 5 11-14-17 REV. FOR CONSTRUCTION <br /> GROUND A <br /> A _ <br /> NEUTRAL BUS ISOLATED NON—HAZARDOUS AREA HAZARDOUS AREA ULR = UNLEADED REGULAR Q <br /> PUMP CONTROL FROM GROUND & ULP = UNLEADED PREMIUM B <br /> ELECTRICAL PANEL <br /> FROM DISPENSER ISOLATION BONDING SKREW REMOVED RIGID CONDUIT FROM DISPENSERS ULM = UNLEADED MID GRADE B _. <br /> RELAYS PER NEC 2 0-61(b) <br /> SWITCHED HOT "VEEDER-ROOT" TLS-350 W/ PRINTER MODEL SVR-848290-122 (WITH THE FOLLOWING CONFIGURATION) 0 <br /> ( 120 OR 240 VAC. ) ELECTRICALLY ISOLATED LOW VOLTAGE SIDE SENSOR LOCATED <br /> IN SUMP (1) VR-330160-160 RISK MANAGEMENT SOFTWARE 1 <br /> PUMP IN (PI) GROUND BUS (INSULATED JUNCTION BOX <br /> FROM THE PANEL VIA A WEATHERPROOF J-BOX HYDROSTATIC Q <br /> NON-CONDUCTIVE MOUNTING) „� SUMP (1) VR-330404-010 WAYNE DIM MODULE <br /> + "�E + "° SENSOR SEAL: <br /> ____7 <br /> F.E. PETRO "IST-VFC" o (1} VR-848703-010 WAYNE DIM INSTALL KIT —� <br /> REMOTE CONTROL BOX z METALLIC CONDUIT, DO NOT ESSI <br /> z o ROUTE THROUGH AC TROUGH TYPICAL AT (1) VR-330020-425 ETHERNET TCP/IP INTERFACE MODULE QR�F - �Hq� <br /> ,yK r, SENSOR LOCATED <br /> 00 TLS-35OR MONITOR IN SUMP DISPENSERS & (1) VR-331943-002 NVMEM2 MEMORY UPGRADE Fyc <br /> OPIIOW�L 3 HP WIRING RIGID <br /> 200-250V CONDITIONED u' CONDUIT AT VENT SUMP <br /> POWER SUPPLY PROVIDED 3 PH L2 SEE NOTE ,) 2-IN-1 SUMP (1) VR-330162-XXX SEM UPGRADE HAL P. GRUBB ?� <br /> 1 P OPnONN-SWnCH (eW2) to O <br /> THROUGH PUMP L1 ® rn n ® ® © D SENSOR SENSOR -- <br /> ELECTRICAL DISTRIBunoN GN o s @ @ @ @ sox (1) VR-329356-005 COMBO INTERFACE MODULE - FOUR INPUT PROBE INTERFACE 878 <br /> CONTROL CENTER Pr&ssuRE o + •T•-,-• �/// <br /> �SOEcr (swi) ® a . . . . . . . . . . . . . . ® WITH FOUR INPUT INTERSTITIAL LIQUID SENSOR INTERFACE I <br /> DRESS (sW5) AC NEUTRAL �eeene�ee�eeeee <br /> 1,5V o MAG PROBE LOCATED <br /> NEUTRAL Ac LINE IN FILL SUMP (1) VR-329359-001 FOUR RELAY OUTPUT MODULE <br /> WEATHERPROOF J-BOX <br /> ® � „� TANK 1 VR-330280-001 BIR PROTOCOL DIM P <br /> RIGID CONDUIT +r'-.' -�+ LEVEL O O 1 V <br /> o+T -' .: '�'�' - GAUGING (1) VR-330843-001 6 INPUT PLLD MODULE FOF CA ��/0 <br /> ss�s sss a aam„Be ease[ • 4•BOCK (2) VR-330374-001 3 OUTPUT PLLD CONTROLLER MODULE --- L <br /> 11 GND <br /> ELKSENSOR <br /> MOTOR } SNNFI�L/TURewEDSUMPHYDROSTATIC (1) VR-332250-001 SEVEN INPUT W/ PRESS. SMART CARD <br /> "S.- <br /> ORGNEUTRAL Jy 15A LEAK <br /> RED 120V L BREAKER WEATHERPROOF J-BOXDETECTION (1) VR-329356-004 EIGHT INPUT SMART CARD <br /> + WEEFILL/TURBINE (2) VR-329358-001 EIGHT INPUT INTERSTITIAL/LIQUID SENSOR INTERFACE MODULE Control Wiring" and "system description" SUMP x <br /> TO for specific wiring connections and <br /> SUBMERSIBLE 9 • • b OucK STANDARD D_ <br /> speed/dip switch settings. SENSOR LOCATED Z <br /> PUMP LLD MANUAL N TURBINE/FILL SUMP LEAK <br /> .' «'-'-'-Ti°-- �. <br /> NO. 576013-902 REV. "H" OR HIGHER eeeesss®®®sasses ressssseesss DETECTION <br /> • • • .W W.w.W« 2-IN-1- TURBINE/FILL <br /> BOXsoR SUMP <br /> 0 4-M <br /> - 0 0 SINGLE FLOAT SENSOR TYPICAL AT DEVELOPMENT INFORMATION: <br /> IN HYDROSTATIC TANK 6i <br /> ® @ WEATHERPROOF J-BOX RESERVOIR LEAK ARCO NTI <br /> PUMP OUTPUT PO 6ee966eae66 <br /> N <br /> F.E. PETRO "IST-VFC" •gym` +.K1°" DETECTION <br /> REMOTE CONTROL BOX MODIFIED V) <br /> MASTER REGULAR HYDROSTATIC <br /> OPROWL 3 HP WIRING RIGID CONDUIT SEE NOTE 10 �WRUCK RESERVOIR 5000 8111/pIT1 <br /> 200-250V CONDITIONED o HF PaG a ON 1`.� b '""' -" PLLD SENSOR w/ 26'x65' CAR WASH <br /> POWER SUPPLY 3 PH LZ FOR Ta oN ` IN TURBINE SUMP PRESSURE , <br /> 1 P ®PoR MWstER JI ll WEATHERPROOF J-BOX o <br /> PROVIDED THROUGH L, LINE LEAK FUEL CANOPY w/ 8 MPD's <br /> PUMP ELECTRICAL GN SET PRESSURE <br /> DISTRIBUTION CONTROL asEUECT{sWt) pFnsnippeE�ss OPTIONAL AUDIBLE HORN DETECTION I, <br /> CENTER <br /> nSff1OFO +swa ro <br /> 1N R w _SUVE TURBINEo <br /> NNs PM S)ER .NS anON y,N.cR SUMP SITE ADDRESS: \ <br /> NEUTRAL 15Ta NSTA 1014 d' <br /> OWNER'S MN! M. <br /> TRINITY PARKWAY <br /> NOTE: <br /> DIAGRAM SHOWN IS BASED ON A SPARE_ @ SCOTT CREEK DRIVE <br /> 22K UK MASTER-SLAVE IST SET UP. IF AN ALTERNATE <br /> s crouuuNtcnnox CONDUCTOR VACUUM SENSOR <br /> cN0 (oPlwNn�coNNEcnoN) SINGLE MASTER IST SET UP IS USED, REFER IN TURBINE SUMP — — STOCKTON,C <br /> I TO VEEDER ROOT PROGRAMMING MANUAL, & WEATHERPROOF J-BOX VACUUM <br /> Buc TOI IOTOR THE FE PETRO TECHNICAL BULLETIN DATED +wWin SENSOR <br /> 0 JUNE 12, 2001, FOR VEEDER-ROOT TLS-350 IN TURBINE FACILITY # TBD o <br /> RED & FE PETRO INTERFACE WIRING. <br /> A��acK SUMP DESIGNED BY: ALLIANCE Z&DM: <br /> CHECKED BY: SP REPM: _C� <br /> -- RIGID <br /> CONDUIT SENSOR LOCATED <br /> FROM EACH WEATHERPROOF J-BOX IN DISPENSER CABINETVAPOR TYPICAL AT DRAWN BY: AWALq <br /> TANK11 FLOW DISPENSER VERSION: PROJECT NO: g <br /> wnRE <br /> METER 16700 0 <br /> RIGID CONDUIT <br /> FROM EACH •aucx <br /> DRA G � <br /> DISPENSER i <br /> SENSOR LOCATED <br /> WEATHERPROOF J-BOX IN DISPENSER CABINET AT ONLY ONE ELECTRICAL FUELING DETAILS <br /> SENSOR WIRING SHALL BE INTRINSCALLY +•WRRE VAPOR DISPENSER FOR VEEDER ROOT& a <br /> SAFE WIRING BELDENHA CABLE BB760 FOR PRESSURE POWER DISTRIBUTION CENTER <br /> EACH SENSOR/PROBE (TYPJ SENSOR (25K&12K(8KTANKS) .o <br /> 5 L <br /> SHEET NO: °J <br /> E <br /> 0 <br /> 0 <br /> TO ISTS <br /> 0 <br /> HIGH VOLTAGE Xx NOTE INDICATES ITEMS FOUND ON MATERIALS KUM <br /> Typical Master/Slave IST Wiring Diagram <br /> JuNcnoN sox <br /> LIST SHEETS M.5.3.01 & M.5.3.02 <br /> a <br /> SCALE: NTS <br />