28 22 23 PRIMARY CLIENT. <br /> ------ <br /> RETALIX ALLIED EC <br /> POS ANDI BOX LOW PUMP D#1P N <br /> BOX VOLTAGE <br /> TLS-350 26 PIB DISPENSER (SERIAL RS-485) FD ISP Leak Detection System Notes <br /> WIRING #2 <br /> 20 DISCONNECT 1. WARNING: <br /> (PUMP INTERFACE BOARD) O >- DISP <br /> 2 250TYP MONITOR SENSOR & PROBE WIRING IS INTRINSICALLY SAFE WIRING AND MUST BE SEPARATE <br /> FROM ALL OTHER WIRING AND INSTALLED IN SEPARATE CONDUIT. MAXIMUM CABLE LENGTH <br /> CAT �_ BETWEEN MONITOR CONSOLE AND SENSORS IS 1,000 FEET. <br /> J-BOX <br /> OR DEBM 3 2. CAUTION: <br /> CAT RS-485 120 VAC WIRING MUST NOT BE CONNECTED TO LOW VOLTAGE CONNECTIONS. DAMAGE FROM <br /> INTERFACE MISWIRING FROM MISWIRING IS NOT COVERED BY WARRANTY, INSTALLING CONTRACTOR TO BE <br /> HELD RESPONSIBLE. <br /> 3. INSTALL TANK MONITOR SYSTEM PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> DB9 CONTROL <br /> SAM TERCOM/COM CABLE RS-485 PIC 4. USE BELDEN CABLE # 88760 OR APPROVED EQUAL FOR ALL SENSOR AND PROBE WIRING. <br /> DEBIT 251 WIRING <br /> 5. RUN RIGID METAL CONDUIT FOR PROBE AND SENSOR WIRING FROM THE MONITOR CONSOLE <br /> DB9 CONTROL TO THE INTRINSICALLY SAFE WIREWAY. CONDUIT MUST ENTER THE MONITOR WHERE <br /> CABLE KNOCKOUTS ARE PROVIDED. NO OTHER CONDUIT ENTRY IS PERMITTED. <br /> ETHERNET SHARED CONDUIT <br /> 252 WIRING CAT 5DISP (CAT 5 & 6. SPECIAL NOTE: IT IS THE INTENT OF THIS DESIGN THAT ANY DETECTED LEAK OR ANY FAILURE ARCO <br /> INTERCOM) TO EACH OF THE LEAK DETECTION SYSTEM, WILL RESULT IN THE INTERRUPTION OF ALL POWER TO THE <br /> DISCONNECT #1 <br /> Des CONTROL r DISPENSER PRODUCT PUMPS. ARC <br /> CABLE 3 DISP (TYPICAL) BP WEST COAST PRODUCTS,LLC <br /> TERCOM�COM INTERCOM it #2 7. CERTIFIED INSTALLERS- ALL MANUFACTURERS TRAINING REQUIREMENTS SHALL BE MET BY <br /> 251 WIRING (BELDEN CABLE #88760) CONTRACTOR INSTALLING PROBES AND WIRING TO MONITORING SYSTEM AS BEINGS DISPENSER <br /> ISCONNFCTDISP WIRING. <br /> TYP 8. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO NOTIFY THE VEEDER ROOT <br /> DISTRIBUTOR FOR STARTUP. <br /> LOW VOLTAGE DISPENSER WIRING DISCONNECTS 9. SEE MANUFACTURERS WIRING DIAGRAM FOR SPECIFIC WIRING AND FURTHER INFORMATION. <br /> PRIMARY DISCONNECT: Power Integrity Corp. Model: DDS-8DM4WPE WIRE THE EQUIPMENT AS REQUIRED BY THE MANUFACTURERS WIRING DIAGRAM. <br /> COM DISCONNECT (PIC): Power Integrity Corp. Model: DDS-8DB4C (IF PIC is located <br /> NOTE: in Dispenser) 10. EACH TURBINE RELAY IS TO BE WIRED INTO THE MONITOR CONTROL SO THAT AN ACTIVATION n V <br /> OPTIONAL "MSI" POS CAN INTERCOM DISCONNECT: Power Integrity Corp. Model: DDS-8DB4C OF TURBINE SIDE SUMP PROBE OR ANNULAR SPACE PROBE WILL SHUT DOWN THE TURBINE y 2 <br /> BE WIRED SIMILARLY ETHERNET FOR THAT TANK. s may. <br /> DISCONNECT: Power Integrity Corp. Model: DDS-EWS8D(Wall Mount) <br /> or DDS-ERS8D (Rack Mount) G�TiNG ENGj1N�� <br /> ARCO WAYNE " NON - e " TO RETALIX POS <br /> 1 <br /> SCALE: NTS 18215 72ND AVENUE SOUTH <br /> KENT, WA 98032 <br /> (425)251-6222 <br /> (425)251-8782 FAX <br /> CIVIL ENGINEERING, LAND PLANNING, <br /> SURVEYING, ENVIRONMENTAL SERVICES <br /> NO. DATE REVISION DESCRIPTION <br /> 1 9-6-16 PERMIT SUBMITTAL <br /> 2 12-14-16 PERMIT RESUBMITTAL <br /> 3 1-31-17 PERMIT RESUBMITTAL <br /> 4 8-16-17 CONSTRUCTION RELEASE <br /> Q 11-14-17 REV. FOR CONSIRUCRON <br /> CAT 5 Cable Installation Guide IST-VFC NOTES VEEDER-ROOT TLS-350 NOTES <br /> 7 <br /> D <br /> 1. EXCESSIVE FORCE SHOULD NOT BE USED TO PULL IN NEW CABLE. PULL FORCE SHOULD NOT EXCEED REQUIREMENTS FOR THIS SYSTEM: i WARNING: IN INSTALLATION AND USE OF THIS PRODUCT, Q <br /> 25 LBS. 1. TWO OR MORE VFC CONTROL BOXES WITH REVISION 1.5 SOFTWARE (SEE FIGURE 2). PLEASE COMPLY WITH THE NATIONAL ELECTRICAL CODE: FEDERAL, D <br /> 2. CABLE SHALL NOT BE KINKED, KNOTTED, OR OTHERWISE DEFORMED DURING INSTALLATION. CONTACT FE PETRO FOR AVAILABILITY. STATE AND LOCAL CODES. IN ADDITION, TURN OFF POWER Q <br /> 2. VEEDER-ROOT TLS-350 WITH VERSION 27 TLS SOFTWARE. PLEASE CONTACT VEEDER-ROOT FOR AND TAKE OTHER NECESSARY PRECAUTIONS DURING Q <br /> 3. PROPER CABLE SUPPORT HARDWARE SUCH AS J-HOOKS SHALL BE USED TO PREVENT RIPPING OR AVAILABILITY. INSTALLATION, SERVICE AND REPAIR TO PREVENT PERSONAL 2 <br /> FRAYING OF CABLE. WHERE USED, STAPLES SHALL BE NON-METALLIC PLASTIC. STAPLE SHOULD BE 3. SET THE VFC WITH THE PLLD TRANSDUCER INSTALLED IN ITS PUMP TO BE THE MASTER VFC. INJURY, PROPERTY LOSS AND EQUIPMENT DAMAGE. SEAL' <br /> LOOSE ENOUGH SUCH THAT CABLE JACKET IS NOT CRIMPED. 4. 18 AWG 3-WIRE SHIELDED COMMUNICATION CABLE (300 V MINIMUM) CONNECTING VFCS. pFESS/p <br /> WARNING: DISCONNECT ALL POWER BEFORE MAKING AN I Nq <br /> 5. AN FE PETRO MODEL 65 PSI CHECK VALVE OR ANON-VENTED CHECK VALVE SHALL BE i COONS TO PREVENT DEATH, SERIOUS INJURY, �� �Fy <br /> 4. CABLE BUNDLES MAY BE SECURED WITH LOOSE FITTING WIRE TIE OR VELCRO TIE WRAPS. CABLES INSTALLED ON THE SLAVE PUMPS (IF USED). EXPLOSION OR ELECTRICAL SHOCK. MONITOR MUST NEVER BE _`' �'i <br /> SHALL NOT BE OVER TIGHTENED SUCH THAT CRUSH STRESS IS EVIDENT. 6. WIRE VFC CONTROLLERS ACCORDING TO FIGURE 3 OF FE PETRO TECHNICAL BULLETIN TS-015, HAL P. GRUBB <br /> DATED JUNE 12, 2001, OPERATED UNLESS THE FRONT COVER IS CLOSED OVER THE v F <br /> 5. CABLE SHALL BE ROUTED TO PERMIT SWEEPING BENDS, NOT RIGHT ANGLES OR SHARP BENDS. CABLE 7. INSTALLATION MANUALS FOR BOTH VEEDER-ROOT TLS-350 & FE PETRO VFC WILL BE AVAILABLE BARRIER TERMINALS IN THE INTRINSICALLY SAFE AREA. 4 <br /> RUNS SHALL BE INDIVIDUALLY SUPPORTED. DURING INSTALLATION. <br /> 6. A MINIMUM OF CABLE JACKET SHALL BE REMOVED WHEN TERMINATING. CABLE JACKET SHALL EXTEND NOTES: <br /> BASIC OPERATION FOR THIS CONFIGURATION: Q. <br /> AS CLOSE AS PRACTICAL TO THE TERMINATION POINT, LEAVING NO MORE THAN 3/4 INCH OF WIRE 1. WIRING TO PROBES, SENSORS, & PLLD MUST BE SHIELDED MULTI-STRAND, GAS AND 9 1 V 1 <br /> EXPOSED. 1. THE VEEDER-ROOT TLS-350 SYSTEM MONITOR THE TANK PRODUCT LEVELS. OIL RESISTANT SIZES FROM AWG #18 TO AWG #14. BARRIER GROUND WIRING MUST BE TF Op OA�0 <br /> 7. MAINTAIN TWISTED CONFIGURATION OF WIRE PAIRS TO WITHIN 1/2 INCH OF THE TERMINATION POINT. <br /> 2. WHEN DEMAND FOR PRODUCT IS CALLED FOR, A 120 VAC HOOK SIGNAL FROM DISPENSER IS AWG #12 OR LARGER. <br /> PRESENT, THE VEEDER-ROOT TLS-350 SYSTEM WILL TURN ON A PUMP ACCORDING TO THE PRODUCT <br /> LEVEL IN THE TANKS, DICTATED BY CONSOLE CONFIGURATION, OR LARGE <br /> 12 AWG R <br /> 3. WHEN DEMAND FOR PRODUCT RISES, MORE PEOPLE DISPENSING PRODUCT, WHICHEVER VFC IS IN 2. CONNECT WITH EARTH GROUND BUS AT THE POWER DISTRIBUTION PANEL.CONDUCTOR THE BARRIER GROUND TO THE <br /> 8. WIRES SHALL NOT BE SPLICED. DAMAGED CABLE SHALL BE REPLACED, NOT REPAIRED. THE LEAD POSITION CAN CALL FOR ADDITIONAL VFC TO TURN ON. <br /> 9. LEAVE APPROXIMATELY 18 INCHES OF SPARE WIRE AT OUTLET AND CONNECTION POINT. 4. WHEN THE DEMAND FOR PRODUCT GOES AWAY, THE VEEDER-ROOT SYSTEM WILL PERFORM A LINE 3. (j)DENOTES FIELD WIRING CONNECTION USING WATERPROOF CONNECTORS SUPPLIED X <br /> LEAK TEST USING THE VFC DESIGNATED AS THE MASTER ACCORDING TO VEEDER-ROOT'S LINE TEST S S <br /> 10. ENSURE ADEQUATE SEPARATION WHEN RUNNING CAT 5 CABLE PARALLEL TO POWER WIRING. CABLE PROTOCOL. WITH THE PROBE(S) AND SENSOR(S). <br /> Z <br /> 5. IN THIS CONFIGURATION, IF THERE ARE ANY FAULTS IN THE SYSTEM THE WHOLE SYSTEM WILL BE <br /> SHALL NOT BE ROUTED THROUGH SAME BORE HOLES AS POWER WIRING. WHERE POSSIBLE CAT 5 SHUT DOWN. 4. INTRINSICALLY SAFE WIRING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE a <br /> CABLES SHOULD CROSS POWER WIRES AT 90 DEGREE ANGLES. MAINTAIN SEPARATION BETWEEN CABLE 504-20 OF THE NEC ANS/NFPA 70, 1990. Z <br /> AND OTHER WIRING AS FOLLOWS: THE WIRING DIAGRAM IN FIGURE 1 SHOWS THE CONNECTIONS BETWEEN THE VEEDER-ROOT POW R BAY <br /> CONSOLE AND THE MASTER/SLAVE VFCS 5. TO MAINTAIN INTRINSIC SAFETY AND PROPER SYSTEM OPERATION, PROBE AND o <br /> SENSOR WIRING MUST BE INSTALLED WITHIN SEALED CONDUIT. DEVELOPMENT INFORMATION: o0 <br /> 1. FOLLOW ALL SAFETY AND INSTALLATION INSTRUCTIONS IN THE VEEDER-ROOT SITE PREP AND ARCO NTI o° <br /> PURPOSE TYPE OF WIRE MIN. SEPARATION INSTALLATION INSTRUCTIONS FOR THE VEEDER-ROOT TLS-350. 6. ELECTRICAL RATING POWER INPUT - 120VAC, 50/60 HZ, 600 WATTS MAX. ------- o <br /> 2. FOLLOW ALL SAFETY AND INSTALLATION INSTRUCTIONS IN THE IST-VFC INSTALLATION AND OWNERS MODIFIED <br /> OPEN WIRING LESS THAN 300 VOLTS 2 INCHES MANUAL FOR WIRING NOT SHOWN IN FIGURE 1. 7. REFER TO "SITE PREPARATION AND INSTALLATION INSTRUCTIONS," MANUAL NO. N <br /> 3. SET SW3 SWITCHES ACCORDING TO MASTER-SLAVE CONFIGURATION NOT FOR MASTER-SLAVE 576013-622 FOR ACTUAL LOCATION OF CONDUIT ENTRY INTO TLS-350 MONITOR. 3000 am/pm <br /> POWER SUPPLY WIRE IN CONDUIT OR ARMORED OR ALTERNATING CIRCUIT (M-S/AC), IF VFCS ARE SET IN M-S/AC THE PUMPS WILL NOT TURN ON IN A W/ 26'x65' CAR WASH <br /> NON-METALLIC SHEATH CABLE/POWER NONE PREDICTABLE MANNER. 8. REFER TO LINE LEAK DETECTOR "SITE PREPARATION AND INSTALLATION," MANUAL NO. FUEL CANOPY w/ 8 MPD's <br /> GROUND WIRES 4. CALIBRATE CONTROLLERS ACCORDING TO CALIBRATION INSTRUCTIONS IN IST-VFC INSTALLATION AND, 576013-764. <br /> OWNERS MANUAL. <br /> RADIO & TELEVISION ANTENNA LEAD & GROUND WIRES 9. RS-232 MODULE IS LOCATED IN THE COMMUNICATIONS COMPARTMENT AND MUST BE SITE ADDRESS: <br /> WITHOUT GROUNDED SHIELD 4 INCHES o <br /> ADDITIONAL NOTES: ORDERED SEPARATELY. TRINITY PARKWAY <br /> SIGNAL & CONTROL WIRE OPEN WIRING NOT OVER 300 VOLTS NONE i. FOR ADDITIONAL INFORMATION, REFERENCE VEEDER-ROOT SITE PREPARATION AND INSTALLATION 10. BONDING LOCKNUTS AND OR BONDING BUSHINGS SHALL BE USED AT ALL CONDUIT @ SCOTT CREEK DRIVE <br /> MANUAL 576013-902 FOR INSTALLATION INSTRUCTIONS OF PLLD USING A MASTER/SLAVE ENTRANCES TO THE TLS-350R ENCLOSURE AND AT ANY JUNCTION BOX/WIRING TROUGHS STOCKTON,CA <br /> COMMUNITY TELEVISION SYSTEMS CONFIGURATION. IN THE NON-HAZARDOUS AREA TO ENSURE POSITIVE CONDUIT GROUNDING. E <br /> CATV CABLES COAXIALCABLES WITH GROUNDED NONE <br /> SHIELD 2. A NON-VENTED CHECK VALVE, VEEDER-ROOT PART NUMBER VR-330020-416, OR FE PETRO 11. SOFTWARE ENHANCEMENT MODULE REQUIRED (#330160-012) AND MUST BE FACILITY # TBD <br /> MODEL 65-PSI CHECK VALVE MUST BE INSTALLED ON THE SLAVE TANK TURBINE TO ENSURE PROPER ORDERED SEPARATELY. o <br /> TELEPHONE SERVICE <br /> OPERATION OF SYSTEM AND PROVIDE ADEQUATE LINE LEAK PROTECTION. SEE FE PETRO TECHNICAL DESGNED BY: ALLIANCE ZBDM: <br /> 3 <br /> AERIAL OR BURIED 2 INCHES SERVICE BULLETIN TB-015, DATED JUNE 12, 2001, FOR MORE SPECIFIC DETAILS. 12. FOR 2 PUMPS IN SINGLE TANK OPERATION, PUMP SENSE MODULE REQUIRED CJffCNED - --- ----- <br /> DROP WIRE (#847490-204) AND MUST BE ORDERED SEPARATELY. IF USING PLLD, PUMP SENSE RP REPM: o <br /> 3. THE VEEDER-ROOT TLS-350 SYSTEM MUST BE PROGRAMMED USING THE CORRECT DISPENSER MODULE IS NOT REQUIRED (ELECTRONIC LINE LEAK DETECTOR IS DOING THE PUMP DRAWN BY: ALLIANCE PM: <br /> SIGN NEON SIGNS AND ASSOCIATED WIRING MODE. THE PROGRAMMER MUST SELECT THE MANIFOLDED ALTERNATE MODE IN THE PLLD SET-UP SENSE . <br /> FROM TRANSFORMER 6 INCHES SECTION. SEE VEEDER-ROOT SYSTEM SET-UP MANUAL 576013-623 FOR SPECIFIC PROGRAMMING ) VERSION: PROJECT NO g <br /> INSTRUCTIONS. 13. NO SPLICING OF PROBE/SENSOR WIRE EXCEPT AT THE DEVICE ITSELF. _ 16700 0 <br /> FLUORESCENT LIGHTING FLUORESCENT LIGHTING WIRE 5 INCHES 4. THE VEEDER-ROOT TLS-350 MUST BE PROGRAMMED USING THE MANIFOLDED TANK SET-UP. THE DRAWING TITLE: <br /> PROGRAMMER MUST ASSIGN THE MASTER TANK T-1 TO LINE LEAK DETECTOR Q-1. THE SLAVE TANK 14. CONTRACTOR MUST COMPLY WITH ALL THE TRAINING REQUIREMENTS OF <br /> T-2 TO LINE LEAK DETECTOR Q-2. SPECIFIC PROGRAMMING QUESTIONS SHOULD BE DIRECTED TO VEEDER-ROOT. IST-IFC, CATS <br /> LIGHTNING SYSTEM LIGHTNING RODS AND WIRES 6 FEET &VEEDER-ROOT <br /> VEEDER-ROOT TECHNICAL SUPPORT DEPARTMENT BY CALLING 800-323-1799. 15. SPECIFIC PROGRAMMING FOR VEEDER ROOT TLS-350 CONSOLE SHALL BE OBTAINED NOTES <br /> FROM THE LOCAL ENVIRONMENTAL COMPLIANCE MANAGER. <br /> t <br /> SHEET NO: <br /> E <br /> CD <br /> 0 <br /> 0 <br /> XX <br /> NM INDICATES ITEMS FOUND ON Mm,5130 � <br /> MATERIALS LIST SHEETS M.5.3.01 & M.5.3.02 <br /> a <br /> L� <br />