My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2017 INSTALL PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10715
>
2300 - Underground Storage Tank Program
>
PR0541281
>
INSTALL 2017 INSTALL PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 4:35:43 PM
Creation date
11/6/2018 10:58:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2017 INSTALL PLANS
RECORD_ID
PR0541281
PE
2361
FACILITY_ID
FA0023650
FACILITY_NAME
Trinity Parkway AMPM ARCO #83819
STREET_NUMBER
10715
STREET_NAME
TRINITY
STREET_TYPE
Pkwy
City
Stockton
Zip
95219
APN
6602002
CURRENT_STATUS
01
SITE_LOCATION
10715 Trinity Pkwy
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\T\TRINITY\10715\PR0541281\2017 INSTALL PLANS.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLIENT: <br /> by <br /> �T <br /> Expansion Dispenser Wiring Disconnect for Low <br /> Circuit Conductors Circuit Conductors Voltage Circuits <br /> Low Voltage Equipment Low Voltage Equipment <br /> I —I OUTPUTS ,— I <br /> A B C D A e (1) This product is an expansion disconnect to be used <br /> 25 SHIELD SHIELD with a DDS- "Dispenser Wiring Disconnect Solution". <br /> (2) Mount the unit in a location convenient to the low <br /> Control 0 00 0 0 000 0 0 0 voltage wiring to be controlled and to the "Dispenser <br /> INPUT From O o 0 0 0 0 o Wiring Disconnect Solution". <br /> DDS <br /> Systems 17 X1 X8 <br /> [t.'0rh..rrDDTS <br /> "'I OU (3) Connect the low voltage circuit conductors from the <br /> dispensers to the input terminals. Be sure to match <br /> ysts the dispenser circuit to the input/output terminal set. <br /> 0 0 0 0 0 0 0 (4) Connect the low voltage circuit conductors from the AR <br /> 0 O O 000 output terminals to the low voltage equipment. VCO <br /> BP WEST COAST PRODUCTS,LLC <br /> (5) Connect a DB9 extension cable from the controlling <br /> t A B SHIELD C DI A B SHIELD Dispenser Wiring Disconnect Solution to the "Control <br /> Circuit Conductors INPUTS Circuit Conductors Input". <br /> From Dispenser From Dispenser �&H A <br /> (6) If additional expansion disconnects are to be used V <br /> connect them to the Control Output. <br /> n U <br /> O <br /> y z <br /> B: DATA DISCONNECT WIRING SCHEMATIC DETAIL-INTERCOM DISCONNECT s°<r ��y <br /> ANG N� <br /> Remote Transformer: Transformer is to be connected to an NOT TO SCALE ENG� <br /> Q <br /> Output 18-24 VAC Max Q Q AC Outlet/Circuit Controlled by FTI <br /> ❑ 18215 72ND AVENUE SOUTH <br /> _ + 100ma Minimum O Emergency Stop System Q KENT, WA 98032 <br /> Connections F 1 Class 7 + <br /> 1 (425)251-6222 <br /> ❑ Connecting the +0 CAT 3A CAT 4A 00 + (425)251-8782 FAX <br /> Dispenser CAT Wiring Typical Dispenser 2 CREDIT <br /> CREDIT _ <br /> Credit Card CARD -Q 4A 0 2 CARD CIVIL ENGINEERING, LAND PLANNING, <br /> ❑ Connecting the Data Wiring -CAT- +O 7 0 (— Q + -CAT- SURVEYING, ENVIRONMENTAL SERVICES <br /> 2 Dispenser Data Wiring CH3 3-O O-3 CH4 � <br /> Connect LP1 CAT 3B JP5 4B CAT 4B <br /> 3A Data In 4+0 J 0+4 LO No. DATE REVISION DESCRIPTION <br /> �, -o �`,� - 0 - <br /> - Connect LP2 TB 1 •- TB 2 U 9-6-16 PERMIT SUBMITTAL <br /> Data In Typical Dispenser LL! r <br /> ^--•� •--• 1N,_„". W 2 12-14-16 PERMIT RESUBMITTAL <br /> Data Wiring to _0 0_ U) - - <br /> Connect CH3 CAT Data Out g z •-:- z 3 1-31-17 PERMIT RESUBMITTAL <br /> '3C (Remove JP5 Jumper for CH3A W ��►' '•--� �•-• I; <br /> and CH3B Separate Operation) L— 'ILL 1 +Q .aa abbaaliaaaa oad _ "w" 01 + a 8-16-17 CONSTRUCTION RELEASE <br /> Connect CH4 CAT Data Out —�— 2- <br /> 3D (Remove JP6 Jumper for CH4A WAYNE p O JP6 02- <br /> 5Q 11-14-17 REV. FOR CONSTRUCTION <br /> 3+O 03+ � <br /> and Cl Separate Operation) SITE CONTROLLER4 0 <br /> LV Transformer DISPENSER 0 4- DISPENSER <br /> ❑ - <br /> 4A Connection (1) DATA 5 +005 + DATA ETHERNET Output Jacks. Front View D _ <br /> CAT-3A -- <br /> � (2) (LP1) 6-0 Q g_ (LP2) e <br /> ❑ E-Stopped LV <br /> 46 Input Power Wiring £ CAT-3B (3) 8+Q 5 O 8 + <br /> (Dispensers 9 - 16 ) 0 <br /> FConnection Point for y !4) Oo TB 3 TB 6 TB 7 0 mO NC3 (e 0 0 <br /> Grounding Conductor TB 4 owaR NTrc Rrt°v ° ° D <br /> u'+ 15) QQOOQQQQO QQQQQQQQQ O ® ® ® ®� ® ® ® 0 <br /> CAT-4A <br /> OrD (8) +3A- +3B- 1 2 4 5 6 1 2 4 5 6 +46- +4A- O Q Q Q Q Q p 2 <br /> t6 15 14 13 12 11 10 9 <br /> 16 15 14 13 12 11 10 9 For Compliance with NFPA®30A,Section 6.7 and SEAL: <br /> 7 Low Voltage Dispenser Wiring Disconnect NECO Sections 514.11 and 514.13 <br /> W CAT-41B ! ) � <br /> ( ) 0 3C I 13A 3B I 3D Typical Dispenser B 7 6 5 4 3 2 �o QRp�ESS10Nq��y <br /> g L Optional Optional Credit Card e 5 s 4 3 x 1 <br /> ?� LP-1 O CAT 36 I I CAT4B CH3/CH4 ® O O ® 0 <br /> (10) CAT Charges ® �� <br /> (13) — I to Site Controller 0 HAL P. GRUBB <br /> (14) <br /> ETHERNET Output Jacks. Status Indicators <br /> ( Dispensers 1 - 8) F Q <br /> OF 2,IIFo��tI�!! CAUTION !! CALF1 <br /> t The Dispenser Wiring Disconnect Solution must be grounded in order to provide protection. I <br /> For the protection modules to function properly they must be connected to a suitable ground.A#8 ground wire should be <br /> connected from the ground bar and routed and connected to the electrical system ground electrode.The ground conductor Front View I <br /> should be routed as short as possible. <br /> m <br /> X <br /> DATA DISCONNECT WIRING SCHEMATIC DETAIL-Wayne EC INSTALLATIONS Q <br /> Remote Input z <br /> NOT TO SCALE: From Expansion <br /> Remote Output Disconnects DEVELOPMENT INFORMATION: o <br /> to Expansion ARCO NTI <br /> Dispenser 1 - 8 <br /> Disconnects MODIFIED <br /> Dispenser 1 - 8 ETHERNET Intput Jacks. 3000 am/pm <br /> w/ 26'x65' CAR WASH <br /> ( Dispensers 1 - 8) FUEL CANOPY W/ 8MPD'S o <br /> N <br /> O SITE ADDRESS: I� <br /> 0 <br /> ® ems: � <br /> TRINITY PARKWAY <br /> En <br /> 1 2 3 a 5 s 7 B @SCOTT CREEK DRIVE ro <br /> STOCKTON,CA 0 <br /> E <br /> ry rE 11-AN L—A FACILITY # TBD 9 10 11 12 13 14 15 16 <br /> 0 <br /> 0 O O O O LO <br /> DESIGNED BY: ALLIANCE ZdrDM: <br /> CHECKED BY: DP REPM: <br /> ETHERNET Input Jacks. <br /> DRAWN BY: ALLIANCE PM: M <br /> VERSION: PROJECT NO,. <br /> Remote Output Remote Input (Dispensers 9- 16 ) 16700 <br /> to Expansion to Expansion DRAWING TITLE: <br /> Disconnects Disconnects Back View <br /> ELECTRICAL PANEL E-STOP <br /> Dispenser 9 - 16 Dispenser 9- 16 DATA/INTERCOM/ETHERNET <br /> WIRING DIAGRAM <br /> SHEET NO: <br /> C: DATA DISCONNECT WIRING SCHEMATIC DETAIL-ETHERNET DISCONNECT <br /> a <br /> NOT TO SCALE: <br /> RUN <br /> eXX NOTE: INDICATES ITEMS FOUND ON <br /> MATERIALS LIST SHEET M.5.3.01 & 0 <br /> L� <br />
The URL can be used to link to this page
Your browser does not support the video tag.