My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1998-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
BILLING 1998-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 1:30:39 PM
Creation date
11/7/2018 9:22:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1998-2005
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\4407\PR0231761\BILLING 1998-2005.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y 11 • <br /> STATE OF CALIFORNIA ""SOV,�r-, <br /> STATE WATER RESOURCES CONTROL BOARD �'�49 m o <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE [Lj_-8'FANK REMOVED Fo <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 1 ' <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.k I I <br /> B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) 1 D. TANK CAPACITY IN GALLONS: QO <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> p to REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> 5:],�MOTOR VEHICLE FUEL F74 OIL a. 7C <br /> PRODUCT 115-PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY <br /> „`tCUGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOYO <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ i LE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK E�j<BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER UNED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ED 91 NONE 5 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,650. SPILL CONTAINMENT I LED(YEAR) OVERFILL PRE N EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRI ERPLATE YES_ NO DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OIICULIV UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND ACU) 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 LVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D, LEAK DETECTION EllMECHAMCAL LINE UE ED 2 LINE TK WWSS O 3 CONUNUWS IWVSTRML 4 ELEWIONIL UNE O 5 AWOWnC PUMP a 99 OTHER <br /> DETECTOR TESTING MONITORING LEAK DETECTOR SHUTDOWN <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK 2 gECONCILIAT <br /> TEONORV ❑ 3 VADOZEMONITORING ❑ 4 GAUGING AUTOMATIC TANK ❑5 GROUND MONITORING TER ❑ 6 TESTINOTANK <br /> [ED <br /> 7 MON TORWG INTERSTITIAL ❑ 8 SIR ❑ 9 TWEEKLY ANK GAUGING TESTING <br /> ❑10 MONTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNS) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ED NO <br /> f SUBSTANCE REMAINING O GALLONS INERT MATERIAL? <br /> 0 LF <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY D TO THE BEST 4 <br /> MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAM A ` DATE <br /> (PRINTED a SIGNATURE) Y nN�✓- P ?r 2 <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW U <br /> COUNTY# JURISDICTION# FACILITY# ��- ,1-7 <br /> TANK# <br /> STATE 01 m <br /> 5' 1111 <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLI -FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. F UST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PIWE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THIW OUND-SST7ORAGE�E TANK REGULATIO <br /> FORME (6 95) f�-' �i 61 <br /> MJ <br />