My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1998-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
BILLING 1998-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 1:30:39 PM
Creation date
11/7/2018 9:22:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1998-2005
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\4407\PR0231761\BILLING 1998-2005.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD "t a <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM F—] 2 INTERIM PERMIT f74 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE [ TI NNK REMOVED' O C9 <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A OWNER'S TANK 1.D. _ B. MANUFACTURED BY: (J(L/kN OU.J <br /> C. DATE INSTALLED(MO/DAYNEAR) ,J,n. r 1/,7/11 D. TANK CAPACITY IN GALLONS: / Bm J' <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. �/ <br /> A 52-1-MOTOR VEHICLE FUEL ❑ 4 OIL B. C. '�ey�p GUWi UNLEADED Q 3 DIESEL ❑ 6 AVIATIONGAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT EL 11c Al DGRADIUME UNLEADED ❑ 5 JET SFUEL ❑ 8 M85 ANOI <br /> ❑ 3 CHEMICALPRODUCT O 95 UNKNOWN ❑ 2 WASTE 2 LEADED ❑ 99 OTHER(DESCRIBE N ITEM D.BELOW) <br /> D. IF(AA)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C.AND ALL THAT APPLIES IN BOX DME)E <br /> A. TYPE OF D 1 DOUBLE WALL O 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 6 UNLINED 95 UNKNOWNN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO..IL <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP [j 2 COATING ❑ 3 WRAP E:] 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN O 99 OTHER <br /> E.SPILL AND OVERFILL,etc. SPILL CONTAINMENTJHSTALLED(YEAR) OVERFILL PEY <br /> RENION EQUIPMENT INSTALLED(YEAR) f <br /> DROP TUBE YES NO STRIKER PLATE YES_✓ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDCCU"*UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A&,2 PRESSURE A U 3 GRAVITY A U 4 PLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 AL INUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U LVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ET Wawnru ME IEuc 2 uxE TwlrtCd <br /> K% 3 MM=51RIERGiIILLL 4 EU:CINOMC UNE 5 AWOM M PUW ❑ <br /> OEIEOTOR STNG MO MNG ❑ MIX WrEMM ❑ EHUmOWN 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ NUAL <br /> 1 VISUAL CHECK 171 2 RECO CILATIONINVENTORY ❑ 3 MONIITORING VAOZE ❑ 4 GAUGING TANK AUTOMATI ❑5 MONITORINGOUNDWATER ❑6 TTEESTINGTANK <br /> ❑ UAL <br /> 7 <br /> MONITORING INTERSTITIAL O 8 SIR ❑ 9 WEEKLTANK AUG MANUAL <br /> ❑10 MONTHLYTESTING TANK ❑ 95 UNKNOWN ❑99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) `_ 2.ESTIMATED OUANTTTY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES ❑ NOgall <br /> THIS FORM HAS BEEN CO P ED UNDER PE LTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNE AM 1, A DATE <br /> (PRINTED461GNA ` <br /> s v (� <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.# m I 11 -7161111Q <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUSTSHOULD BE ACCOMPANIED BY AIPLOT FIWLEFORM A,UNLESS A THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THRENT FORM A HAS 13EEN FILED. IWROUND STORAGEUST BE ED FOR NS.THIS FORM <br /> TANK REGULATIONS <br /> FORM B (6-95) .� <br />
The URL can be used to link to this page
Your browser does not support the video tag.