INSTALL_PLAN 1996
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
INSTALL_PLAN 1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 1:28:44 PM
Creation date
11/7/2018 9:30:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
PLAN 1996
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\5611\PR0231764\INSTALL PLAN 1996.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o � <br /> a Q9 � a <br /> �__________________________ __________________________ _________________________ ___ ___----------- ------------------------------------- <br /> 04 BARS, 6,_8,1 MIN., <br /> e 4" O.G., TYPICAL <br /> TANK GAWE MANHOLE i c2 <br /> \ / \ / . / , I\ /I �, ♦ \ / \/ i � 4, / <br /> i \\y \ / I�// ♦ \ / ` /♦ ,�-. /♦ . / I \y \ - s/ // , \` \ . % - . /♦ � J ANNULAR SPACE <br /> - - - ' �C,- - - 1 /+� - - �. ^/ _._.....: -I- �\ . ,. / / ..•., :.-.: __.........,ti ..__../.'•� PROBE MANHOLE <br /> ORLANDO,S <br /> PRODUCT FILL MANHOLE <br /> \/!V\�i I 5611 E. WATERLOO RD. <br /> \/ " \ 5TOCKTON, CA 95215 <br /> / / X � ♦ I / / )( \ \ BEGINNING OF CROWN _ I _ <br /> I / / \ ♦ GROWN SLAB TO I" AT MANWAYS <br /> --------1-----=------------ - ---------------------------1.---------'--,--` (2(D9) 931 2942 <br /> ---- ----------------------------------------------- APN 081-100-52 <br /> - 36 MANWAY, H-20 RATED, MIN. L r <br /> 8" THICK REINFORCED GONG. <br /> 18" SLAB W/ 04 REBAR 9 18" O.G. <br /> BOTH WAYS (FIELD BARS NOT SHOWN) ALTON <br /> EYP• '� TANK - SLAB PLAN NGINEERING, INC. <br /> SCALE: 1/2 1'-0" <br /> P.O. BOX Ii <br /> 643 RISKS LANE <br /> U)EST SACRAMENTO, GA 95691 <br /> 191(p) 312-1888 <br /> SUBMERGED TURBINE 36" MANHOLE, H-20 RATED, MIN. 8" THICK REINFORCED CONC. `. PAX 313-1112 <br /> PUMP MANIFOLD ASSEME�LY SLAB W! '4 REBAR <br /> W/ LEAK DETECTOR EXPLOSION PROOF "J" 18" O.C. BOTH WAYS <br /> "4 REBAR TO BE PLACED BOX W/ SEAL-OFF, TYP. CROWN SLAB ruESE DRAWNGO AND sPEcFlcanONe,AS <br /> AROUND MANHOLES (TYP.) 5 GAL. FILL CONTAINMENT I' a MANWAYB FROPERTY OF SEE THE <br /> A.T.G. CAP MANHOLE W/ FILL CAP 18"0 WATERTIGHT AND SHALL NOT 0E L&ED iOR ANY PURPOSE <br /> 42"m X 32"0 FIBERGLASS KIT, TYp. o TOP SEAL ADAPTOR, TYP. `2"TYP. MANHOLE OTHER THAN THOSE FOR WHICH THEY HAVE <br /> CONTAINMENT SUMP W/ LID, TYP. 1 BEEN&1PK ED OR PREPARED.THESE DRAW@GS <br /> SHALL NOT BE REPROpY.ED,COPIED OR TRACED <br /> IIATHOUT THE EXPll WRITTEN CONSENT CO <br /> —.a•— a d n -' - •.° ._•- �'"-` —• n — - <br /> 11111.tON ENGNEERRYa, MC. <br /> d < a l <br /> = O = COPYRIGHT © 1998 <br /> — —I n. <br /> o <br /> CONDUIT TO PUMP RELAY ` .:• -i <br /> 4N 0 SLK. IRON p D BY MEL <br /> j o -II — I <br /> _ FLEX GONGTR 1 <br /> _ I SUMP MONITOR _ RISERS (TYP.) <br /> L w/ 3wIVEL(a). - 'v � - I ' I I— CNKD' BY RJH11-iL <br /> ! ' I ATTACHED SUMP CO LAR HOUSING W/ - � III III. <br /> � ' BY TANK MANUFACTURER, LIQUID SEN8ING PLUG/5EAL — - -- 2`0 RISER -J <br /> - - PROBE, TYP. - <br /> I_ !j - UNUSED BUNGS. PATE 3P> AUCs 96 <br /> SCQom. - <br /> ALE 11211-011 <br /> 3' 4, FRP VAPOR LINE. 4" EXTRACTOR 2"0 FRP VENT LINE. <br /> 4x2x 2 VAPOR/VENT SLOPE A MIN. OF 1/8' PER FITTING W/ BALL SLOPE A MIN. OF I/8' PER JOB NO. 26610 <br /> EXIRAGTOR ASSEMBLY FT. BACK TO TANK, TYP. FLOAT VALVE FT. BACK TO TANK, TYP. <br /> —, TYP. OMIT AT DIESEL SECTION. <br /> W/ <br /> BALL VALVE2"41 F.R.P. PRODUCT LINE, W/ 3"0 CONTAINMENT OVERFILL — 12 MIN. (TYP.) REVISION$ <br /> F.R.P. PIPE. SLOPE PIPE A PREVENTION VALVE -- <br /> MIN. OF 1/6"/FT. BACK — PATE REV DESCRIPTION B <br /> IF FILTER FABRIC REQUIRED: 1'-8" I'•2" I i'-2" _ 2'-0' V-0" 2'-10" ! _ <br /> ,,r- TO THE TANK SUMP, TVP. _ <br /> INSTALL FILTER FABRIC LINING _ T P TYp. or TVP. TYP. NATIVE SOIL (TYP.) <br /> ON THE BOTTOM AND ALL -. <br /> SIDES OF WALLS W/ 2'-0" 6,000 GALLON SUPER UNL 6,000 GALLCIN DIESEL <br /> OVERLAP AT TOP EXCAVATION. <br /> IN WET-HOLE APPLICATIONS _ ---- <br /> PUMP EXCAVATION DRY PRIOR - - <br /> TO INSTALLATION. <br /> III-I - <br /> _I ' I I - <br /> I_I MA5NET05TRIGTIVE <br /> 1-1TANK GAUGE — - --- <br /> 45' FIELD CUT BY TANK MNFR (TYP.)TANK STRIKER PLATE <br /> —ANNULAR SPACE - <br /> _ PROBE <br /> .•PEA'GRAVEL BAGKFILG(TYPT <br /> . ' .• " .. III �iII-III I <br /> (rYPi II I =1!'I Ii SPEET TITLE <br /> I� <br /> II III III—III <br /> I TANK <br /> SECTION, <br /> SLAB <br /> TANK SECTION - UNLEADED GASOLINE <br /> SCALE: 1/1 = I'-0" <br /> (PET - 3 <br /> i 6 SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.