INSTALL_PLAN 1996
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
INSTALL_PLAN 1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 1:28:44 PM
Creation date
11/7/2018 9:30:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
PLAN 1996
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\5611\PR0231764\INSTALL PLAN 1996.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXTEND VENT RISER 18" MIN. P/V CAP <br /> ABOVE ADJACENT ROOFS, AND 3" WATER COL. PRESSURE PRODUCT PIPE o <br /> 12 FT. MIN. ABOVE GRADE. 8" WATER COL. VACUUM <br /> (NON PN CAP s DIESEL VENT) 9 <br /> PROVIDE CORRO51ON <br /> PROTECTION FOR BARE MTL- MINIMUM BURY - VARIES BY PIPING SIZE <br /> PIPE: PVC WRAP BELOW AND PAVING CONDITIONS. INSTALL <br /> GRADE, PAINT ABOVE. — BLACK IRON RISER <br /> I VAPOR PIPE PER MNFR'8. REQUIREMENTS, <br /> —1 '; GRADE Ve <br /> —! ' I FIBERGLASS SECONDARY A ° qp <br /> 1 — I CONTAINMENT 45' ELBOW. <br /> FRP BUSHING, <br /> BELL x MALE FIBERGLASS SECONDARY eM <br /> CONTAINMENT TEE m 45' O '�` <br /> FRP VENT PIPING, SWING JOINT, TYP. e <br /> C <br /> SLOPE '/s"/FT. MIN. 70 TANK, e I e , • . r g q/A <br /> • —_ _.._. _.— ___ Q v0 <br /> VENT RISER TRANSITION DETAIL ° <br /> 4 — — — PEA GRAVEL BACK FILL <br /> 3 <br /> SCALE: /a <br /> J e <br /> FIBERGLASS PRIMARY PIPE WITH BOTTOM OF TRENCH <br /> SECONDARY CONTA6NMENT FIBERGLASS <br /> PIPE. SLOPE PIPE BACK TO TANK <br /> PRODUCT SHEAR VALVE— VAPOR SHEAR VALVE A MIN. CF 1/8" PER FOOT. <br /> TOP OF ISLAND 0MC700H ORLANDO'S <br /> STL. ISLAND FORM S I 5611 E. WATERLOO RD. <br /> 5TOCKTON, CA 95215 <br /> (209) 931-2942 <br /> FLOAT CHAIN 4 APN 0al-100-52 <br /> LINKAGE <br /> r <br /> FLOAT - 5 oz. of liquid - � <br /> tripe shear valve <br /> o � _ <br /> MALE-BELL FRP S.S. CLAMP, TYP. <br /> ADAPTER, TYP. <br /> FLEX CONNECTOR <br /> CONTAINMENT W/ SWIVEL <br /> OVER <br /> PIPING PRODUCT _.--- CONTAINMENT 500T PIPING CROSS-OVER, TRENCH DETAIL ALTON <br /> OVER VAPOR RETURN SCALE: I'% " P-O" NGINEERING, INC. <br /> FLEX CONNECTOR <br /> E <br /> P.O. BOX 1025 <br /> BRAVO BOX - SHEAR VALVE DETAIL 843 AMENRISKE Lave <br /> rJ UJe$7 SACRAMENTO, CA 95691 <br /> NTS: PRODUCTP/R OFFSET EXACafaERATED FOR CLARITY (FAXSlb) 312-18881112 <br /> FAX 373-Ii't2 <br /> TANK SUMP <br /> THESE DRAWN<S MID SPECFICATIONB,AS <br /> PENETRATION CONTAINMENT BOOTS, NbTR11ENTB OF SERVICE,ROUN THE <br /> BULKHEAD FITTINGS, AND REDUCERS PROPERTY OF WALTON ENOINEERW., NG <br /> NOTE: PENETRATION BOOTS SHALL BE COMPATIBLE W/ MP SHALL NOT BE USED FOR ANY PURPOSE <br /> AND/OR BULKHEAD FITTINGS FLEX CONNECTOR - PETROLEUM 4 METHANOL/ETWANOL OTHER THMJ THOSE FOR O.NICH THEY HAVE <br /> SHALL BE COMPATIBLE W/ W/ SWIVEL(S) FUEL PRODUCTS VOR BLENDS BEEN SUPPLIED OR PREPARED.THESE DRAUWA <br /> NOTE: SEAL THE CONTAINMENT BOOT OR PETROLEUM 4 METHANOL/ETHANOL SHALL NOT BE REPRODUCED,COPIED OR TRACED <br /> RITTEN <br /> BULKHEAD FITTING TO THE INSIDE FACE FUEL PRODUCTS VOR BLENDS uatuaT THE EXPRESS LLRM, COMM OF <br /> OF THE SUMP W/ "UNIROYAL 1 � , LL'ALTON ENGNEERIN3, NO. <br /> ADHESIVE/SEALANT "SILAPRENE", PART --- IN BULKHEAD <br /> FNMENT r. COPYRIGHT © 1998 <br /> No. 6336, OR APPROVED EQUAL <br /> /<. BOOT (SEAL PER NOTE) <br /> FIBERGLASS THREADED <br /> ADAPTER BELL 4 FEMALE. TANK BUMP FIBERGLASS THREADED SECONDARY CONTAINMENT <br /> ADAPTER, BELL 9 MALE FIBERGLASS PIPE W/ FIBERGLASS DRAUdd BY MEL <br /> SWING JOINT — CONTAINMENT BOOT W/ PRODUCT <br /> FOOTEB SLOPE <br /> TO PIS A MIN. ' <br /> STAINLESS STL. HOSE CLAMP REDUCER FITTING W/ TEST vALvE CHKD BY RJH <br /> ASSEMBLY 4 STAINLESS STL. CLAMPS TANK SUMP• <br /> PIPING TO EXTRACTOR FIBERGLASS VENT LINE SECONDARY CONTAINMENT BOOT DATE 30 AUG 96 <br /> .SLOPE ie" PER FOOT NOTE: SEAL THE CONTAINMENT BOOT OR <br /> TO TANK BULKHEAD FITTING TO THE INSIDE FACE (OR BULKHEAD FITTING) <br /> TO BE USED SUMP•�� OF THE SUMP W1 " <br /> ADHESIVE SEALANTIROYAL'SILAPRENE", PART OF SECONDARYRCONTAINMENT PITPE. SCALE 45 NOTED <br /> No. 6376, OR APPROVED EQUAL <br /> JOB NO, 1 26610 <br /> ;ZNPRODUCT PIPE SUMP PENETRATION REVI5ION5 <br /> S TANK SUMP WALL VENT DETAIL 2 SCALE: 111/7" = v-m" DATE REV DESCRIPTION B <br /> SCALE: 11/7 " I'-0" <br /> SUMP MONITOR HOUSING <br /> W/ LIQUID SENSING PROBE <br /> SWING JOINT, 2'V F.R.P. TANK <br /> TYPICAL / y VENT LINE <br /> EXXON STD. 10"x795" COL., SPACED \ SEAL ALL SUMP PENETRATIONS <br /> FOR NON-CANOPY SPREADER (NCS) SUBMERSED TURBINE W/ CONTAINMENT 1300T8 OR <br /> PUMP ASSEMBLY o BULKHEAD FITTINGS <br /> 6 — ' 18" H. BUMPER GUARD �. <br /> SHEET TITLE <br /> L MPO v PLUG/SEAL UNUSED BUNG <br /> 4x EXTRACTOR <br /> _ ASSEMBLY FCR VENT <br /> 3'-9" <br /> 1_ I AND VAPOR RETURN / y♦ FRP VAPOR RETURN LINE <br /> PETROLEUM <br /> r OMIT ON DIESEL TANK DETAILS <br /> PRODUCT LINE <br /> W/ SECONDARY <br /> CONTAINMENT PIPE. <br /> j DOGBONE ISLAND PLAN 3 GASOLINE TURBINE SUMP PLAN C <br /> SCALE: NONE SCALE: 4 - 1 0 G <br /> OF ra SHEETS <br /> c <br />