D. Results of Testing/Seryicing <br /> Software Version Installed: 120.02 <br /> Complete the following checklist: <br /> ❑X Yes ❑No* Is the audible alarn►operational? <br /> ❑X Yes ❑No* is the visual alarm operational? <br /> ❑X Yes ❑No* Were all sensors visually inspected functionally tested,and confirmed operational? <br /> ❑X Yes ❑No* Wo <br /> ere all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br /> ll not interfere with their <br /> pr <br /> per o peration? <br /> ❑ Yes ❑No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> ❑X N/A operational? <br /> ❑X Yes ❑No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary <br /> ❑N/A containment monitoring system detects a leak, fails to operate,or is electrically disconnected?If yes:which <br /> sensors initiate positive shut-down'?(Check all that apply) <br /> ❑X Sump/Trench Sensors; ❑X Dispenser Containment Sensors. Didyou confirm positive shut-down <br /> due to leaks and sensor failure/disconnection'? <br /> ❑x Yes; ❑N o. <br /> ❑X Yes ❑No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> ❑N/A tank till point(s)and operating properly?If so, at what percent of tank capacity does the alamt trigger? <br /> 90 % <br /> ❑Yes* ❑X No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br /> apply) ❑Product; ❑Water.If yes,describe causes in Section E, below. <br /> ❑X Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ❑X Yes ❑No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were orwill be corrected. <br /> E. Comments: <br /> Other From Section B: <br /> L11:Waste oil overfill sensor 794390-420 certified. <br /> L15:Vent transition sump sensor 794380-208 certified. <br /> L16:Waste oil pan sensor 794380-208 certified. <br /> From Section D:Waste oil tank overfill system electronic solenoid shuts down flow to the tank at the waste oil drain pan. <br /> Unleaded and Diesel tank have a mechanical drop tube overfill prevention valve as primary overfill. <br />