My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1987
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
INSTALL_1987
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:55:08 PM
Creation date
11/7/2018 10:18:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1987
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4040\PR0231963\1987 INSTALL .PDF
QuestysFileName
1987 INSTALL
QuestysRecordDate
8/2/2018 9:19:50 PM
QuestysRecordID
3953873
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specification No. : RGS0024-87 <br /> Part II - SPECIFIC CONDITIONS <br /> Section 9 - Specific Conditions <br /> for Tank Installation <br /> possibility of large boulders or sharp objects damaging <br /> exterior surface of the tank. <br /> 9 . 8. 5 Excavation for Pipe Trenches : Trenches shall be excavated <br /> to the alignment , depth and grade , to suit required pipe <br /> line slope from pump to storage tank . The trench width <br /> for pipes shall be sufficiently large to permit proper <br /> backfilling and compacting . Fuel pipes shall be minimum <br /> 18 inches below the finished grade at the pump island , <br /> vent and vapor pipes shall be minimum 12 inches below the <br /> finished grade at the pump island . <br /> 9 . 8 . 6 Pipe and Bed Backfill : Before underground pipes are laid , <br /> place and compact clean sand in the trench to a minimum <br /> depth of 4 inches . After laying the pipes , place and <br /> compact clean , air-dry sand around and over the pipes to a <br /> minimum cover of 4 inches . Fill the remainder of the <br /> trench with either sand or backfill in 6 inch maximum <br /> layers and compacted to 95 percent of the maximum density <br /> of ASTM 1557-78 , or to the density specified for the <br /> surrounding fill , whichever is higher . Backfill may be <br /> excavated material , provided it does not contain organic <br /> matter and should be placed at close to optimum moisture <br /> content . <br /> 9 . 8. 7 Tank cover shall be 4 feet including the depth of the <br /> concrete slab . <br /> 9 . 9 Testing : <br /> 9 . 9 . 1 Test all piping and calibrate with equipment . Notify <br /> inspection authorities prior to the tests so that they may <br /> be witnessed . Protect all personnel and equipment during <br /> testing . <br /> 9 . 9 . 2 Storage Tanks : Storage tanks shall be tested with an air <br /> pressure minimum 3 PSIG and maximum 5 PSIG before storage <br /> tank is lowered and installed in the excavation in <br /> addition to any tests which may be recommended by the tank <br /> manufacturer . The initial test pressure shall be <br /> maintained without pressure drop for 10 minutes before <br /> inspecting tank seams and pipe opening connections . A11 <br /> seams and connections shall be leak tested at full test <br /> pressure with a soap and water solution . If tanks are <br /> dropped or impacted after initial pressure test , remove <br /> IX-6 <br />