My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1993 - 2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
COMPLIANCE INFO_1993 - 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:47 PM
Creation date
11/7/2018 10:23:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1993 - 2003
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4747\PR0232482\COMPLIANCE INFO 1993-2003.PDF
QuestysFileName
COMPLIANCE INFO 1993-2003
QuestysRecordDate
1/23/2018 8:03:31 PM
QuestysRecordID
3770094
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUE TANK INFORMATION AND . ST RESULTS <br /> it �7anlvaology <br /> TEST DATE:03/14/02 8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER2221349 <br /> CLIENT:CHEVRON, U.S.A. AUSTIN,TEXAS 78757(512)451-6334 SITE:CHEVRON 200764 <br /> Nx hii Y6 is <br /> Tank ID: 87 3 Tank manifolded: NO Bottom to top fill in inches: 92.0 <br /> Product: REG UNLEAD Vent manifolded: NO Bottom to grade in inches: <br /> Capacity in gallons: 11,730 Vapor recovery manifolded:yES Fill pipe length in inches: <br /> Diameter in inches: 92.00 Overfill protection:yES Fill pipe diameter in inches: <br /> Length in inches: 413 Overspill protection:ygs Stage I vapor recovery: DUAL <br /> Material: DW FISERG Installed: ATG Stage II vapor recovery: BALANCE <br /> CP installed on: <br /> COMMENTS <br /> TANK TES RESULTS Test Method:YacuTeal , LEAK t?RT St3l �/jest""a /, <br /> tartm n in <br /> Dipped Water Level: New/passed Failedfreplaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: VEEDERROOT <br /> Ingress Detected: Water Bubble Ullage <br /> Model: ELECTRONIC <br /> Test time: S/N: <br /> Open time in sec: <br /> Inclinometer reading: <br /> Holding psi: zz <br /> VacuTect Test Type: NOT <br /> Resiliency in ml: NOT <br /> VacuTect Probe Entry Point: TESTED Test leak rate ml/m: 1e9.o TESTED <br /> Pressure Set Point: Metering psi: <br /> Tank water level in inches: Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: Pass <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> Lt 1, es pe: 1zo-1 <br /> 4000Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length (ft): 200.0 <br /> Test psi: <br /> Bleedback cc: <br /> Test time(min): NOT NOT NOT NOT <br /> Start time: TESTED TESTED TESTED TESTED <br /> End time: <br /> Final gph: <br /> Result: <br /> Pump type: PRESSURE <br /> Pump make: EE PETRO <br /> COMMENTS Impact Valves Operational:UNKNOWN <br /> Printed 04/02/2002 07:44 <br />
The URL can be used to link to this page
Your browser does not support the video tag.