My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1993 - 2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
COMPLIANCE INFO_1993 - 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:47 PM
Creation date
11/7/2018 10:23:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1993 - 2003
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4747\PR0232482\COMPLIANCE INFO 1993-2003.PDF
QuestysFileName
COMPLIANCE INFO 1993-2003
QuestysRecordDate
1/23/2018 8:03:31 PM
QuestysRecordID
3770094
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® Ill - Y MONITORING SYSTEM CERTIFICATION <br /> r Use By All Jurisdictions Within the State of Cali <br /> Authority Cited:Chapter 6. alth and Safety Code; Chapter 16,Division 3 TitleWalifomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification ora rim <br /> must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this torte must be provided to the tank <br /> system owner operator. a owner operator mus su mite copy o thus o"tote local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 200764 City: STOCKTON CA Zip:95210 <br /> Site Address: 4747 WEST LANE Contact Phone No:956-2520 <br /> Facility Contact Person: MANAGER Date of Testing/Service: 03/14/2002 <br /> Make/Model of Monitoring System: VR TLS-350 Work Order Number: 2221349 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: SUP TanklD: PLS <br /> In-Tank Gauging Probe. Model: 847380-109 In-Tank Gauging Probe. Madel: 847380-109 <br /> 71 Annular Space or Vault Sensor. Model: 794390-407 X Annular Space or Vault Sensor. Model: 794390-407 <br /> Piping SumplTrench Sensor(s). Model: 794380-208 X in Sum 794380-208 <br /> Piping g p?rench Sensor(s). Model: <br /> Fill Sump Sensor(s). Madel: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: 331196-001 X Electronic Line Leak Detector. Model: 331196-001 <br /> Tank OveriilUHigh-Level Sensor. Model: 61SO X Tank Overfill/High-Level Sensor. Model: 61SO <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> an an <br /> In-Tank Gauging Probe. Model: 847380-109 In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor, Model: Annular Space or Vault Sensor. Model: <br /> Piping SumplTrench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> 71 Electronic Line Leak Detector. Model: 331196-001 Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank OverfiltMigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Spenser <br /> ® Dispenser Containment Sensor(s) Model:794380-208 Dispenser Containment Sensors) Model:794380-208 <br /> ® Shear Velvets). Shear Valve(s) <br /> ❑ Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> IspenserDispenser Lr <br /> MDispenser Containment Sensors) Model:794380-208 Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> DispenserlD: 5/6 Dispenser ID: <br /> MDispenser Containment Sensor(s) Model:794380-208 Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). Dispenser Containment Flost(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): System set-up report; ® Alarm history report <br /> PRINTED NAME MICHAEL T LEVESQUE SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03/01 <br />