My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2004 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
BILLING 2004 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 7:59:00 AM
Creation date
11/7/2018 11:58:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2004 - 2011
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1257\PR0231463\BILLING 2004 - 2011.PDF
QuestysFileName
BILLING 2004 - 2011
QuestysRecordDate
9/21/2016 5:59:41 PM
QuestysRecordID
3194243
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIED PROGRAM CONSOLIDATED FO' <br /> L UNDERGROUND STORAGE TANK ..► <br /> MONITORING PLAN - (Page 1 of 2) <br /> TYPE OF ACTION ® 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION 490.1. <br /> $ PLAN TYPE ❑ 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490.1 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) <br /> 1. <br /> BUSINESS NAME(Saw as Facility Name or DBA) AHMED'S SONS INCORPORATED <br /> BUSINESS SITE ADDRESS 1257 W. YOSEMITE AVE 103 1 CITY MANTECA <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers'instruction,or annually,whichever is,more frequent Such work must beperformed by qualifiedpers mel._[23 CCR§u32.2634_2638,26H1 <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY E] 99.OTHER(Specify): 4�3b_ <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,26341 49P4 <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) iihteCx ill/ <br /> g ❑ 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) <br /> 4w5 <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,2634] <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 496$ <br /> PANEL MANUFACTURER: VEEDER-ROOT 490'7, MODEL#: TLS-350 6�- <br /> _ LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-. MODEL#(s): 208 490'10 <br /> ❑ I AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[D CCR§26431 490-11 <br /> PANEL MANUFACTURER: 490.12. MODEL#: 450-13_ <br /> IN-TANK PROBE MANUFACTURER: 114. MODEL#(S): 4e 15, <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS. ❑ b.DAILYINIGHTLY ❑ c.WEEKLY 490.16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17 <br /> PROGRAMMED TESTS: ❑ a 0.1 g.p.h. [Ib.0.2 g.p.h. ❑ c.OTHER(Specify): _49 19i9. <br /> [13.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.1) 4p 2o- <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§2645] TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 4 ;Z"21 <br /> .............................. <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2M3 p 4so-23. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHERS 4eo-24. <br /> ❑ <br /> -9-9.OTHER(Specify): 490.20-26 <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) oexar� <br /> 1 ❑ I.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 49°29_ <br /> [§36CCR 36] SECONDARY CONTAINMENT IS: ® a.DRY [Ib.LIQUID FILLED Elc.PRESSURIZED Eld.UNDER VACUUM 490-3°- <br /> ` PANEL MANUFACTURER:VEEDER-ROOT 410.X MODEL#: TLS-350 490.31_ <br /> LEAK SENSOR MANUFACTURER: VEEDER-ROOT 49°32. MODEL#(S): 409 490- <br /> 33 <br /> ' PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490.34, <br /> FAILUREIDISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a YES ❑ b.NO 490-35. <br /> (� 2,MECHANICAL UNE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 400-36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> _ _ MLLD MANUFACTURER(S): 690'3J- - MODEL#(S): 49°-3s <br /> 3. . <br /> ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.In ccR§2636} -. 490.39. <br /> ELLD MANUFACTURER(S):VEEDER-ROOT 490.4Q. MODEL#(S): PLLD 49°41_ <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490.42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. 10 &YES ❑ b.NO 4v 13_ <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ &YES ❑ b.NO 49°44 <br /> .-_ _._................_____.___._-..._,_... <br /> ❑ 4.PIPE INTEGRITY TESTING. 4904' <br /> 490.46. <br /> TEST FREQUENCY: ❑ &ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 490-47__ <br /> ❑ 5.VISUAL PIPE MONITORING. a9oas. <br /> FREQUENCY: ❑ &DAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED• 400-40 <br /> 'Allowed for mmnkmM ofuphpied emer4enq gmempr fuel piping only per HSC§252915L)(3)______________- <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.In CCR§2636(.X3)1 490-50. <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 440-51. <br /> .._ ............___ .. ............. ._______ _.._..___ -_-___-._ <br /> 4F4 <br /> ❑ 99.OTHER(Specify) 490.os3 <br /> "'. <br /> UPCF UST-D(12/2007)-1/4 w .unidocL rg <br />
The URL can be used to link to this page
Your browser does not support the video tag.