BILLING 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
BILLING 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 10:34:31 AM
Creation date
11/7/2018 12:01:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2012-2015
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1434\PR0231465\BILLING 2012-2015.PDF
QuestysFileName
BILLING 2012-2015
QuestysRecordDate
6/26/2017 3:07:01 PM
QuestysRecordID
3465007
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN— (Page 2 of 2) <br /> VI. UNDER DISPENSER CONTAINMENT(UDC)MONITORING hat(Check apply) <br /> DEC MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> ® L CONTINUOUS ELECTRONIC MONITORING ❑ 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE 490'54" <br /> ❑ 4.NO DISPENSERS ❑ 99.OTHER(Specify) 49o54h. <br /> LEAK MONITOR MANUFACTURER:Veeder-Root 490.55. MODEL p:TLS-350 49056. <br /> LEAK SENSOR MANUFACTURER: Veeder-ROOM 490.57, MODEL X(S):0794380-208 49o.5a. <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ® a.YES ❑ b.NO 490.59. <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490'60. <br /> FAILUREMBCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 4s0'61. <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ❑ a.YES ® b.NO 49 1 <br /> UDC CONSTRUCTION IS: ® I.SINGLE WALL [12.DOUBLE WALL 490x3, <br /> IF DOUBLE WALL: 490fi <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ a.LIQUID ❑ b.PRESSURE ❑ c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a.YES ❑ b.NO 490.1Ab. <br /> VII. PERIODIC SYSTEM TESTING <br /> 1.ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 49x65. <br /> kK&L2gjKQjQKkM MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.lu CCR g2o 4 it <br /> ® 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490.66. <br /> ® 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490-67. <br /> VIII. RECORD KEEPING <br /> 'The following monitoring/maintena oe records are kept for this facility: 49°69. <br /> ® a.ALARM LOGS ❑ b.VISUAL INSPECTION RECORDS ❑ c.TANK INTEGRITY TESTING RESULTS <br /> ❑ d.SIR TESTING RESULTS(and supporting documentation records) ❑ e.TANK GAUGING RESULTS(and supporting documentation records) <br /> ❑ f ATC TESTING RESULTS(and supporting documentation records) ❑ S.CORROSION PROTECTION 60-DAY LOGS <br /> ® h.EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> IX. TRAINING <br /> ® Personnel with UST monitoring responsibilities are familiar with all ofthe following documents relevant to theirjob duties: 49x{9. <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) 490-6%. <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) 490.690. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-6d. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 490690. <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND 490.69E <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 49069% <br /> ❑ OTHER(Specify): 49u-69h <br /> 490.69L <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council 49a-70. <br /> (ICC). The "Designated UST Operator"will train facility employees in the proper operation and maintenance ofthe UST systems annually,and within 30 <br /> days of hire.This training will include,but is not limited to,the following: <br /> D Operation ofthe UST systems in a manner consistent with the facility's best management practices. <br /> D The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br /> ➢ The facility employee's mle with regard to spills and overfills as specified in the facility's UST Response Plan. <br /> ➢ Name(s)of conmct penon(s)for emergencies and monitoring alarms. <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 490-71. <br /> Overfill 95%mechanical flapper <br /> XI. PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Openuor is responsible for ensuring that L)the daily/mutine UST monitoring activities and maintenance of UST leak detection equipment covered <br /> b thi!jlan occurs;2)all conditions that indicate a-possible release are investigated_and 3.)all monitoring records arc maintained properly. <br /> THE FOLLOWING PERSON(S)ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTENANCE: <br /> NAME: Paul Chevalier 490'71. TITLE:Maintenance Manager/Designated Operator 490.]3, <br /> NAME: Romy Quiroz 49a-74 TITLE:Zone Manager 490.75. <br /> The Designated UST Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certifythat the informat' u provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE DATE: 490x7. <br /> Jan 4, 2012 <br /> RFPRESENTmG:®LTerJ<Owncr/0Facilit Own WO er 3.Authorized nWiae ofnwnc <br /> APPLICANT NAME(print): 49o-]e. APPLICANT TITLE: 490.79. <br /> Paul Chevalier Maintenance Manager <br /> UPCF UST-D(12/2007)-3/4 www.unidocs.org <br />