My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 2:02:53 PM
Creation date
11/7/2018 12:28:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\824\PR0231459\COMPLIANCE INFO 2013 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
2/21/2017 6:51:40 PM
QuestysRecordID
3341688
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY 10 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazclto.^.Avenue, Stockton, Califomia 05205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.orD/ehd <br /> UNDERGROUND STOR4iTE TANK(UST) PROGRAM NSPECT!ON REPORT CONTINUED <br /> Facility Quick and EasyFood Mart Facility 824 E Yosemite Ave., Manteca DatInspe <br /> Jun 30, 2014 <br /> Name: Adtlress: Date: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> 61=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurtzed Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (Mi) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Onsite to conduct a routine Underground Storage Tank (UST) inspection and observe monitoring system <br /> certification conducted today. <br /> MINOR-Notice to Comply: 104, 105, 113, 204, 205, 303, 307 <br /> 104. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. A copy of updated financial <br /> responsibility documents were submitted to the EHD at the time of inspection, in the future log into <br /> CERS, upload the required information, and submit for review by the EHD. CORRECTED. <br /> 105. UST Facility Operating Permit Application and UST Tank Information are not current in CERS. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log <br /> into CERS, update the required information, and submit for review by the EHD. Complete a separate <br /> tank form for each tank. <br /> 105. UST Facility Operating Permit Application is lacking BOE Maintenance Fee Account Numbers or <br /> BOE number is incorrect. Immediately log into CERS, update the required information, and submit for <br /> review by the EHD. <br /> 113. Anew designated operator was hired in May of 2014 and notification was not provided to the <br /> EHD within 30 days of the change. Any changes shall be reported to the EHD with 30 days. <br /> Immediately, submit notification to the EHD identifying all the designated operators for this facility. <br /> Alternatively, log into CERS, upload the required information, and submit for review by the EHD. <br /> Complete by July 30, 2014. -j� fUrrt7 LO Cld YoJiC4Q�4 f —�t ,e {;vtnQ p( <br /> �5'pee�Q;Qn- �.ot'reeF-eat <br /> ALL EHD STAFF TIME ASSOCIATED WITH FARING TO COMPLY BY THE ABOVE NOTED DATES WILL BE Bit I W AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inane Receiratl er Tina: <br /> ti Q w w-ly <br /> EHD 23-02 Rea 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.