My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 2:02:53 PM
Creation date
11/7/2018 12:28:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\824\PR0231459\COMPLIANCE INFO 2013 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
2/21/2017 6:51:40 PM
QuestysRecordID
3341688
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sCov.oralehd <br /> CONTINUATION FORM Page: 4 of 5 <br /> OFFICIAL INSPECTION REPORT Date: 06/30/14 <br /> Facility Address: 824 E Yosemite Ave., Manteca Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> 204. The designated operator failed to check and note the correct test dates for the secondary <br /> containment on the October 2013 through June 2014 designated operator monthly inspection reports. <br /> The correct test date should be 10-17-2014 and not the listed 10-29-2014 testing date. During the <br /> monthly inspection, the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and document the dates they were done. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> 205. The April 2014 designated operator monthly inspection report was not found on site. Designated <br /> operator monthly inspection reports for the previous twelve months shall be retained on site. Locate and <br /> ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br /> maintained on site. Submit a copy to the EHD by July 30, 2014. <br /> 303. The 87-octane, 89-octane and 91-octane sump sensors were mounted to sump walls with screws <br /> and were located approximately 3-4 inches off the lowest point of the sump (up the saddle of the sump <br /> floor and not located to detect a leak at the earliest opportunity). The UDC 7/8 sensor was raised <br /> approximately 1/2 inch of the sump floor. Monitoring equipment shall be maintained to be able to detect a <br /> leak at the earliest possible opportunity. The technician relocated the sensors to the respective lowest <br /> points at the time of this inspection. CORRECTED. <br /> 307. During the inspection it was noted that the STP sump sensors in two STP sumps are attached to <br /> the sump walls with screws. All secondary containment for the UST system must be tight. Immediately <br /> evaluate the sumps to verify that these installed components will not jeopardize the sump integrity or <br /> interfere with the secondary containment testing. If these installed components jeopardize the sump <br /> integrity or interfere with the secondary containment testing have a properly licensed, trained, and <br /> certified contractor repair the altered components under permit and inspection of the EHD. Submit proof <br /> of correction to the EHD by July 30, 2014. <br /> Note: Facility operators are required to upload the following UST program documents into the <br /> California Environmental Reporting System (CERS): UST Facility Operation and Tank Information <br /> Forms, UST UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response <br /> Plan, UST Owner/Operator: Written Agreement (if applicable), UST Letter from Chief Financial Officer, <br /> and Owner Statement of Designated UST Operator Compliance. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAIUNG TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: I Rece y: TNe: <br /> Elena Manzo (209) 953-7699 UWP ' <br /> EHD 23-02-003 Rev 04/19/12 COry TiNUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.