COMPLIANCE INFO 2013 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 2:02:53 PM
Creation date
11/7/2018 12:28:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\824\PR0231459\COMPLIANCE INFO 2013 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
2/21/2017 6:51:40 PM
QuestysRecordID
3341688
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 • Page_of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: 0 Sump Manufacturer ®Industry Standard O Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum ®Hydrostatic <br /> D Other(Specify) <br /> Test Equipment Used:WATER,INCON STS Equipment Resolution:.000I" <br /> Sump#REG STP Sump#PLUS STP Sump#PREM STP Sump# <br /> Sump Diameter: 42" 42" 42" <br /> Sump Depth: 44" 44" 44" lFrX111r. D <br /> Sump Material: FIBER FIBER FIBER <br /> Height from Tank Top to Top of 18" 18" 18" FEB 12 2014 <br /> Hi est Piping Penetration: <br /> Height from Tank Top to Lowest 14" 14" 14" ENVIRONMENTAL <br /> Electrical Penetration: <br /> Condition of sump prior to testing: DRY/CLEAN DRY/CLEAN DRY/CLEAN <br /> Portion of Sump Tested' 2211 22" 22" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both 0 Yes O No DNA OYes D No DNA 0 Yes 0 No 0 NA D Yes D No DNA <br /> roduct and water?� <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe <br /> shutdown? 0 Yes 0 No DNA 0 Yes 0l b DNA OYes ONo DNA OYes ONO DNA <br /> Was fail-safe verified to be 0 Yes 0 No DNA 0 Yes ONO DNA 0 Yes o No DNA OYes ONo DNA <br /> o erad a]? <br /> Wait time between applying <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 1235 1235 <br /> Initial Reading(RI): 4.3672 1.2604 <br /> Test End Time: 1250 12.50 <br /> Final Reading(110: 4.3667 1.2597 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(Rr-&): .0005 .0007 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Test Result: O.Pass D Fall (9 Pass 'D Fall 0 Pass O Fail... D Pass O Fail <br /> Was sensor removed for testing? 0 Yes D No 0 NA ❑Yes 0140 DNA OYes ONO DNA 0 Yes 0 No 0 NA <br /> Was sensor properly replaced and 0Yes ONo 0 N OYes ONo DNA OYes ONo DNA DYes ONo DNA <br /> verified functional after testing? <br /> _CoMmentS—(include information on repairs made prior to testing, and recommendedfollow-upforfailed tests) <br /> Regular sump not tested due to torn secondary boot in stn sump. <br /> t if the entire depth of the sump is not tested, specify how much was tested. If the answer to=of the questions indicated with an <br /> asterisk(*)is"NO"or`TNA",the entire sump must be tested. (See SWRCB LG-160) <br />